Vibration analysis of cryocoolers

被引:85
作者
Tomaru, T
Suzuki, T
Haruyama, T
Shintomi, T
Yamamoto, A
Koyama, T
Li, R
机构
[1] KEK, High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[2] Sumitomo Heavy Ind Ltd, Tokyo 1888585, Japan
关键词
cryocooler; vibration; pulse-tube; Gifford-McMahon;
D O I
10.1016/j.cryogenics.2004.02.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vibrations of Gifford-McMahon (GM) and pulse-tube (PT) cryocoolers were measured and analyzed. The vibrations of the cold-stage and cold-head were measured separately to investigate their vibration mechanisms. The measurements were performed while maintaining the thermal conditions of the cryocoolers at a steady state. We found that the vibration of the cold-head for the 4 K PT cryocooler was two orders of magnitude smaller than that of the 4 K GM cryocooler. On the other hand, the vibration of the cold-stages for both cryocoolers was of the same order of magnitude. From a spectral analysis of the vibrations and a simulation, we concluded that the vibration of the cold-stage is caused by an elastic deformation of the pulse tubes (or cylinders) due to the pressure oscillation of the working gas. (C) 2004 Cryogenic Association of Japan. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 8 条
[1]  
Bendat J.S., 1971, RANDOM DATA ANAL MEA
[2]  
Ikeya Y., 2003, CRYOCOOLERS, V12, P403
[3]   Large-scale cryogenic gravitational wave telescope [J].
Kuroda, K ;
Ohashi, M ;
Miyoki, S ;
Tatsumi, D ;
Sato, S ;
Ishizuka, H ;
Fujimoto, MK ;
Kawamura, S ;
Takahashi, R ;
Yamazaki, T ;
Arai, K ;
Fukushima, M ;
Waseda, K ;
Telada, S ;
Ueda, A ;
Shintomi, T ;
Yamamoto, A ;
Suzuki, T ;
Saito, Y ;
Haruyama, T ;
Sato, N ;
Tsubono, K ;
Kawabe, K ;
Ando, M ;
Ueda, KI ;
Yoneda, H ;
Musha, M ;
Mio, N ;
Moriwaki, S ;
Araya, A ;
Kanda, N ;
Tobar, ME .
INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 1999, 8 (05) :557-579
[4]  
LIENERTH R, 2000, P ICEC, V18, P555
[5]  
MIYAZAWA S, 1996, ANN LECT BOOK REFRIG, P125
[6]  
TOMARU T, 200329 KEK
[7]  
Wang C, 2002, AIP CONF PROC, V613, P641, DOI 10.1063/1.1472076
[8]  
XU MY, 2003, CRYOCOOLERS 12, P301