Urban microclimate and outdoor thermal comfort. A proper procedure to fit ENVI-met simulation outputs to experimental data

被引:285
作者
Salata, Ferdinando [1 ]
Golasi, Lacopo [1 ,3 ]
Volloaro, Roberto de Lieto [2 ,3 ]
Vollaro, Andrea de Lieto [1 ,4 ]
机构
[1] Univ Roma Sapienza, DIAEE Area Fis Tecn, Rome, Italy
[2] Univ Rome Tre, DIMI, I-00146 Rome, Italy
[3] Via Eudossiana 18, I-00184 Rome, Italy
[4] Via Vito Volterra 62, I-00146 Rome, Italy
关键词
Outdoor urban microclimate; ENVI-met; Numerical simulations; Experimental measures; Case study calibration; PMV; HEAT-ISLAND MITIGATION; TURBULENT AIR-FLOW; CLIMATE-CHANGE; CFD SIMULATION; HUMAN HEALTH; GREEN ROOFS; IMPACT; TEMPERATURE; STRATEGIES; VEGETATION;
D O I
10.1016/j.scs.2016.07.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper, while referring to a case study, focuses on the assessment of the input parameters based on the equations solved by ENVI-met. The output data of different micrometeorological variables and Predicted Mean Vote (PMV) were compared to the experimental values measured on the field in different points and for several days. The results provided by the software were examined while taking into consideration a different cell size of the mesh as well. However significant differences were not recognized and the 2 x 2 m(2) cell-sized model was chosen; it represents a good compromise for what concerns results' accuracy and computation time. This gave the possibility to determine a deviation of 0.6% for air temperature, 0.9% for mean radiant temperature, about 2.0% for relative humidity and about 10% for global radiation. The predictive ability of the software was also testified, for air temperature and mean radiant temperature, by the analysis of the coefficient of determination, Root Mean Square Error and Willmott's index of agreement. Then the PMV values were compared with those measured during a field survey with an average deviation of 0.76 units and it was possible to determine how, among the different Lateral Boundary Conditions (LBC), the open type leads to more reliable results. Finally the latest version of the software was tested and in the conclusions a general procedure to perform simulations in ENVI-met is suggested. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:318 / 343
页数:26
相关论文
共 124 条
[1]   A comparison of thermal comfort conditions in four urban spaces by means of measurements and modelling techniques [J].
Acero, Juan A. ;
Herranz-Pascual, Karmele .
BUILDING AND ENVIRONMENT, 2015, 93 :245-257
[2]   Comfort in urban spaces: defining the boundaries of outdoor thermal comfort for the tropical urban environments [J].
Ahmed, KS .
ENERGY AND BUILDINGS, 2003, 35 (01) :103-110
[3]   Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas [J].
Akbari, H ;
Pomerantz, M ;
Taha, H .
SOLAR ENERGY, 2001, 70 (03) :295-310
[4]   Temperature decreases in an urban canyon due to green walls and green roofs in diverse climates [J].
Alexandria, Eleftheria ;
Jones, Phil .
BUILDING AND ENVIRONMENT, 2008, 43 (04) :480-493
[5]   Evaluating Mitigation Effects of Urban Heat Islands in a Historical Small Center with the ENVI-Met® Climate Model [J].
Ambrosini, Dario ;
Galli, Giorgio ;
Mancini, Biagio ;
Nardi, Iole ;
Sfarra, Stefano .
SUSTAINABILITY, 2014, 6 (10) :7013-7029
[6]  
[Anonymous], 1995, 10551 ISO
[7]  
[Anonymous], 2012, WORLD POP DAT SHEET
[8]  
[Anonymous], 2007, 6946 ISO
[9]  
[Anonymous], 1994, 7730 ISO
[10]  
[Anonymous], 1998, 7726 ISO