2-and 3-Monochloropropanediols in paper products and their transfer to foods

被引:21
作者
Becalski, Adam [1 ]
Zhao, Tony [1 ]
Breton, Francois [2 ]
Kuhlmann, Jan [3 ]
机构
[1] Hlth Canada, Food Res Div, Bur Chem Safety Hlth Prod & Food Branch, Locator 2203D, Ottawa, ON K1A 0K9, Canada
[2] Canada Border Serv Agcy, Analyt & Forens Serv Div, Ottawa, ON, Canada
[3] SGS Germany GmbH, Weidenbaumsweg 137, Hamburg, Germany
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2016年 / 33卷 / 09期
关键词
2-monochloropropanediol; 3-monochloropropanediol; gas chromatography-mass spectrometry (GC-MS); food analysis; paperboard; food packaging; FATTY-ACID ESTERS; WET-STRENGTH RESINS; 3-CHLORO-1,2-PROPANEDIOL; 1,3-DICHLORO-2-PROPANOL; CHLOROPROPANOLS; CONTAMINANTS; GLYCIDOL; 3-MCPD;
D O I
10.1080/19440049.2016.1223353
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The occurrence of 2- and 3-monochloropropanediol (MCPDs) in selected paper products sold on the Canadian market and the transfer of 3-MCPD from those products to beverages was probed. Products included coffee filters, tea bags, disposable paper hot beverage cups and milk packaged in paperboard containers. The occurrence MCPDs in coffee and tea filters on the German market was investigated as well. Furthermore, the presence of MCPDs in paper towels on the German market was also investigated. Analytes were determined by stable isotope dilution analysis GC-MS in SIM mode. 3-MCPD was detected in most paper products with levels ranging from a few nanograms in tea bags to a few micrograms in white coffee filters. Milk containers' paperboard contained 3-MCPD at about 500-1500ngg(-1); however, 3-MCPD was detected in milk only in smaller containers, 237-500ml (likely due to a lower volume/surface ratio) at levels of about 1ngg(-1). Out of three disposable hot beverage paper cups tested (of 237-473ml capacity), paperboard of two contained 3-MCPD at 632-792ngg(-1), and 3-MCPD was detected in leachate from those paper cups at levels of about 16ng per cup. 3-MCPD was detected in all paper towels at levels of 42-2466ngg(-1). 2-MCPD was detected in many paper products (from Canadian and German sources) and in all the towels tested at levels varying from about 0.5-10% of that of 3-MCPD.
引用
收藏
页码:1499 / 1508
页数:10
相关论文
共 22 条
[1]   Relative oral bioavailability of 3-MCPD from 3-MCPD fatty acid esters in rats [J].
Abraham, Klaus ;
Appel, Klaus E. ;
Berger-Preiss, Edith ;
Apel, Elisabeth ;
Gerling, Susanne ;
Mielke, Hans ;
Creutzenberg, Otto ;
Lampen, Alfonso .
ARCHIVES OF TOXICOLOGY, 2013, 87 (04) :649-659
[2]   Risks for human health related to the presence of 3- and 2-monochloropropanediol (MCPD), and their fatty acid esters, and glycidyl fatty acid esters in food [J].
Alexander, Jan ;
Contam, Efsa Panel Contaminants Food Chain ;
Barregard, Lars ;
Bignami, Margherita ;
Ceccatelli, Sandra ;
Cottrill, Bruce ;
Dinovi, Michael ;
Edler, Lutz ;
Grasl-Kraupp, Bettina ;
Hogstrand, Christer ;
Hoogenboom, Laurentius ;
Knutsen, Helle Katrine ;
Nebbia, Carlo Stefano ;
Oswald, Isabelle ;
Petersen, Annette ;
Rogiers, Vera Maria ;
Rose, Martin ;
Roudot, Alain-Claude ;
Schwerdtle, Tanja ;
Vleminckx, Christiane ;
Vollmer, Gunter ;
Wallace, Heather .
EFSA JOURNAL, 2016, 14 (05)
[3]   Toxicology, occurrence and risk characterisation of the chloropropanols in food: 2-Monochloro-1,3-propanediol, 1,3-dichloro-2-propanol and 2,3-dichloro-1-propanol [J].
Andres, Susanne ;
Appel, Klaus E. ;
Lampen, Alfonso .
FOOD AND CHEMICAL TOXICOLOGY, 2013, 58 :467-478
[4]   Relative oral bioavailability of glycidol from glycidyl fatty acid esters in rats [J].
Appel, Klaus E. ;
Abraham, Klaus ;
Berger-Preiss, Edith ;
Hansen, Tanja ;
Apel, Elisabeth ;
Schuchardt, Sven ;
Vogt, Carla ;
Bakhiya, Nadiya ;
Creutzenberg, Otto ;
Lampen, Alfonso .
ARCHIVES OF TOXICOLOGY, 2013, 87 (09) :1649-1659
[5]   A pilot survey of 2-and 3-monochloropropanediol and glycidol fatty acid esters in baby formula on the Canadian market 2012-2013 [J].
Becalski, A. ;
Zhao, T. ;
Feng, S. ;
Lau, B. P. -Y. .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2015, 44 :111-114
[6]   Cyclohexanone/sulfonated polymer catalyst: a new simple derivatizing procedure for GC-MS determination of 2- and 3-monochloropropanediols [J].
Becalski, Adam ;
Zhao, Tony ;
Sit, Daniel .
FOOD AND ENERGY SECURITY, 2013, 2 (02) :157-165
[7]   Determination of 1,3-dichloro-2-propanol and 3-chloro-1,2-propanediol in papers treated with polyamidoamine-epichlorohydrin wet-strength resins by gas chromatography mass spectrometry using selective ion monitoring [J].
Boden, L ;
Lundgren, M ;
Stensio, KE ;
Gorzynski, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 788 (1-2) :195-203
[8]  
DEVORE DI, 1991, TAPPI J, V74, P135
[9]   Comparison of indirect and direct quantification of esters of monochloropropanediol in vegetable oil [J].
Dubois, Mathieu ;
Tarres, Adrienne ;
Goldmann, Till ;
Empl, Anna Maria ;
Donaubauer, Alfred ;
Seefelder, Walburga .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1236 :189-201
[10]  
European Commission, 2004, COLL COLL DAT LEV 3