Complete electrolysis using a microflow cell with an oil/water interface

被引:39
作者
Sawada, S
Taguma, M
Kimoto, T
Hotta, H
Osakai, T [1 ]
机构
[1] Kobe Univ, Fac Sci, Dept Chem, Nada Ku, Kobe, Hyogo 6578501, Japan
[2] Kinki Univ, Dept Chem, Fac Sci & Engn, Higashiosaka, Osaka 5778502, Japan
[3] Kimoto Elect Co Ltd, Osaka 5430024, Japan
关键词
D O I
10.1021/ac010934l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel microflow cell with a nitrobenzene (NB)/water (W) interface was developed. A poly(tetrafluoroethylene) membrane filter was employed to prepare the NB/W interface which was formed over a thin channel (0.1 mm thick, 48 cm. long) on a silver plate. The silver plate was electrolyzed in advance and served as an Ag/AgCl electrode for controlling the Galvani potential difference across the NB/W interface as well as detecting the current flowing through the interface. Using the microflow cell, complete electrolysis was accomplished for the interfacial transfer of a representative ion (i.e., tetramethylammonium ion). Thus, the present microflow cell was shown to be promising for coulometric (i.e., absolute quantitative) analysis of ions. Also, the microflow cell was shown to be useful for determination of the number of electrons for complicated charge-transfer processes at the oil/water interface.
引用
收藏
页码:1177 / +
页数:6
相关论文
共 32 条
[1]  
Bard A.J., 2001, ELECTROCHEMICAL METH
[2]  
CUNNANE VJ, 1996, LIQUID LIQUID INTERF, pCH18
[3]   ELECTROLYTIC CHROMATOGRAPHY AND COULOPOTENTIOGRAPHY - RAPID ELECTROLYSIS AT COLUMN ELECTRODE USED FOR PREPARATION, SEPARATION, CONCENTRATION, AND ESTIMATION OF TRACE AND/OR UNSTABLE SUBSTANCES [J].
FUJINAGA, T ;
KIHARA, S .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1977, 6 (03) :223-254
[4]  
GIRAULT HH, 1993, MOD ASPECT ELECTROC, V25, pCH1
[5]   INVESTIGATION OF ION TRANSFER ACROSS THE MEMBRANE-STABILIZED INTERFACE OF 2 IMMISCIBLE ELECTROLYTE-SOLUTIONS [J].
HUNDHAMMER, B ;
DHAWAN, SK ;
BEKELE, A ;
SEIDLITZ, HJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 217 (02) :253-259
[6]   INVESTIGATION OF ION TRANSFER ACROSS THE MEMBRANE STABILIZED INTERFACE OF 2 IMMISCIBLE ELECTROLYTE-SOLUTIONS .2. ANALYTICAL APPLICATION [J].
HUNDHAMMER, B ;
WILKE, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :133-141
[7]   FLOW-INJECTION AMPEROMETRIC DETECTION BASED ON ION TRANSFER ACROSS A WATER-SOLIDIFIED NITROBENZENE INTERFACE FOR THE DETERMINATION OF TETRACYCLINE AND TERRAMYCIN [J].
JI, HM ;
WANG, EK .
ANALYST, 1988, 113 (10) :1541-1543
[8]   A POTENTIAL-STEP CHRONOAMPEROMETRIC STUDY OF ION TRANSFER AT THE WATER NITROBENZENE INTERFACE [J].
KAKUTANI, T ;
OSAKAI, T ;
SENDA, M .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1983, 56 (04) :991-996
[9]   ELECTROLYSIS WITH AN ELECTROLYTE DROPPING ELECTRODE [J].
KORYTA, J ;
VANYSEK, P ;
BREZINA, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1976, 67 (02) :263-266
[10]   Amperometric ion detector for ion chromatography [J].
Lee, HJ ;
Girault, HH .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4280-4285