Acoustic emission monitoring of hybrid FRP-concrete columns

被引:36
作者
Mirmiran, A [1 ]
Shahawy, M
El Echary, H
机构
[1] Univ Cincinnati, Dept Civil & Environm Engn, Cincinnati, OH 45221 USA
[2] Florida Dept Transp, Struct Res Ctr, Tallahassee, FL 32310 USA
[3] Wilbur Smith & Assoc, Orlando, FL 32803 USA
来源
JOURNAL OF ENGINEERING MECHANICS-ASCE | 1999年 / 125卷 / 08期
关键词
D O I
10.1061/(ASCE)0733-9399(1999)125:8(899)
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Fiber-reinforced plastic tubes can be used as permanent formwork and external reinforcement for concrete columns. Failure of such columns is often accompanied by audible noise from cracking of concrete and shifting and settling of aggregates, snapping of the inner layers of the jacket, and ultimately fiber fracture. Since the state of the concrete core is not readily visible from the outside, nondestructive evaluation tools such as acoustic emission (AE) can help assess its structural integrity. The objective of this research was to investigate the applicability of AE technique to hybrid columns, and to correlate the AE parameters to the state of stress in concrete. The AE signature of hybrid columns was studied on over 40 specimens with different lengths, cross sections, jacket types, and jacket thicknesses. The study showed that (1) rate of change of cumulative AE counts with respect to the applied load correlates well with the degree of damage sustained by the concrete core; (2) longer specimens, thicker jackets, and unbonded tubes display higher AE activities; and (3) the Kaiser effect is not present in hybrid columns.
引用
收藏
页码:899 / 905
页数:7
相关论文
共 14 条
[1]  
BERTHELOT JM, 1987, J ACOUSTIC EMISSION, V6, P43
[2]   INNOVATIVE DESIGN OF FRP COMBINED WITH CONCRETE - SHORT-TERM BEHAVIOR [J].
DESKOVIC, N ;
TRIANTAFILLOU, TC ;
MEIER, U .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (07) :1069-1078
[3]  
Hall J.E., 1998, J COMPOS CONSTR, V2, P78, DOI DOI 10.1061/(ASCE)1090-0268(1998)2:2(78)
[4]  
Li L., 1986, PROGR ACOUSTIC EMISS, P522
[5]   ACOUSTIC EMISSIONS FROM REINFORCED-CONCRETE [J].
MAJI, AK ;
SAHU, R .
EXPERIMENTAL MECHANICS, 1994, 34 (04) :379-388
[6]   Acoustic emission source location using lamb wave modes [J].
Maji, AK ;
Satpathi, D ;
Kratochvil, T .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1997, 123 (02) :154-161
[7]  
Malhotra VM, 1976, MONOGRAPH AM CONCRET
[8]  
MCCABE WM, 1976, ACI J, V73, P367
[9]   A new concrete-filled hollow FRP composite column [J].
Mirmiran, A ;
Shahawy, M .
COMPOSITES PART B-ENGINEERING, 1996, 27 (3-4) :263-268
[10]   Design, manufacture and testing of a new hybrid column [J].
Mirmiran, A ;
Samaan, M ;
Cabrera, S ;
Shahawy, M .
CONSTRUCTION AND BUILDING MATERIALS, 1998, 12 (01) :39-49