Effect of inclination angle and fill ratio on geyser boiling phenomena in a two-phase closed thermosiphon - Experimental investigation

被引:49
作者
Alammar, Ahmed A. [1 ,2 ]
Al-Dadah, Raya K. [1 ]
Mahmoud, Saad M. [1 ]
机构
[1] Univ Birmingham, Dept Mech Engn, Birmingham B15 2TT, W Midlands, England
[2] Minist Elect, Training & Dev Off, Baghdad, Iraq
关键词
Two-phase closed thermosiphon; Geyser boiling; Fill ratio; Inclination angle; Temperature oscillation in thermosiphon; HEAT-TRANSFER PERFORMANCE; THERMAL PERFORMANCE; SOLAR COLLECTORS; PIPE; EXCHANGER; SYSTEMS; R-134A;
D O I
10.1016/j.enconman.2017.11.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
Geyser boiling is a complex phenomenon which may occur in heat pipes causing high temperature and pressure oscillation leading to noticeable vibration. Therefore, understanding of such process is essential to improve heat pipes thermal performance and avoid damage. In this experimental study, a comprehensive investigation of several parameters on the characteristics of the geyser boiling has been conducted during the operation of two-phase closed thermosiphon (TPCT) using water as the working fluid. The effect of different inclination angles (90, 60, 30 and 10 degrees) at various fill ratios defined as volume of liquid in the evaporator to the volume of the evaporator (25%, 65% and 100%) on the geyser boiling has been investigated at a broad range of heat load and for various mass flow rates and inlet temperatures of the cooling water. These important parameters have been examined to report the occurrence and period of the geyser effect at each heat input. The results showed that the orientation and the liquid charge have a significant impact on the occurrence and period of the geyser boiling at low and high heat inputs. For example, at a fill ratio of 100%, the geyser boiling occurs at a lower heat input compared with that for fill ratios 25%, 65% at all inclination angles, while it happens at a higher heat load at a low inclination 10 degrees compared with other angles at all fill ratios. In addition, at high input energies, it almost disappears at orientations of 90 and 60 degrees for all liquid charges. Also, comparing with fill ratios of 25% and 65%, a shorter period is observed for a fill ratio of 100% at angles of 90, 30 and 10 degrees, whereas it is longer at 60 degrees and low heat inputs. This work highlights the effects of the operating conditions on geyser boiling in heat pipes.
引用
收藏
页码:150 / 166
页数:17
相关论文
共 32 条
[1]   An experimental study of two-phase closed thermosyphons for compact solar domestic hot-water systems [J].
Abreu, SL ;
Colle, S .
SOLAR ENERGY, 2004, 76 (1-3) :141-145
[2]   Numerical investigation of effect of fill ratio and inclination angle on a thermosiphon heat pipe thermal performance [J].
Alammar, Ahmed A. ;
Al-Dadah, Raya K. ;
Mahmoud, Saad M. .
APPLIED THERMAL ENGINEERING, 2016, 108 :1055-1065
[3]   Comparative heat transfer characteristics of a flat two-phase closed thermosyphon (FTPCT) and a conventional two-phase closed thermosyphon (CTPCT) [J].
Amatachaya, P. ;
Srimuang, W. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (03) :293-298
[4]  
aReay D, 2014, HEAT PIPES, P105
[5]   THE GEYSER EFFECT IN A 2-PHASE THERMOSYPHON [J].
CASAROSA, C ;
LATROFA, E ;
SHELGINSKI, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (06) :933-941
[6]   Experimental investigation of thermosyphon loop thermal performance [J].
Chehade, A. A. ;
Louahlia-Gualous, H. ;
Le Masson, S. ;
Victor, I. ;
Abouzahab-Darnaj, N. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 84 :671-680
[7]   Investigation of Geyser Boiling Phenomenon in a Two-Phase Closed Thermosyphon [J].
Emami, M. R. Sarmasti ;
Noie, S. H. ;
Khoshnoodi, M. ;
Mosavian, M. T. Hamed ;
Kianifar, A. .
HEAT TRANSFER ENGINEERING, 2009, 30 (05) :408-415
[9]   Performance of a cylindrical wicked heat pipe used in solar collectors: Numerical approach with Lattice Boltzmann method [J].
Grissa, Kods ;
Benselama, Adel M. ;
Lataoui, Zied ;
Romestant, Cyril ;
Bertin, Yves ;
Jemni, Abdelmajid .
ENERGY CONVERSION AND MANAGEMENT, 2017, 150 :623-636
[10]   Theoretical and experimental investigation of wickless heat pipes flat plate solar collector with cross flow heat exchanger [J].
Hussein, H. M. S. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (04) :1266-1272