Separation and Precise Measurement of Lithium Isotopes in Three Reference Materials Using Multi Collector-Inductively Coupled Plasma Mass Spectrometry

被引:26
|
作者
Tian Shihong [1 ,2 ]
Hou Zengqian [3 ]
Su Aina [4 ]
Hou Kejun [2 ]
Hu Wenjie [5 ]
Li Zhenzhen [6 ]
Zhao Yue [2 ]
Gao Yanguang [7 ]
Li Yanhe [2 ]
Yang Dan [2 ]
Yang Zhusen [2 ]
机构
[1] China Univ Geosci, Sch Earth Sci & Mineral Resources, Beijing 10083, Peoples R China
[2] Chinese Acad Geol Sci, Key Lab Metallogeny & Mineral Assessment, Minist Land & Resources, Inst Mineral Resources, Beijing 100037, Peoples R China
[3] Chinese Acad Geol Sci, Inst Geol, Beijing 100037, Peoples R China
[4] Chinese Acad Geol Sci, Inst Hydrogeol & Environm Geol, Shijiazhuang 050061, Hebei, Peoples R China
[5] Jiangxi Prov Inst Geol Survey, Nanchang 330030, Peoples R China
[6] Kunming Univ Sci & Technol, Kunming 650093, Yunnan, Peoples R China
[7] China Geol Survey, Beijing 100037, Peoples R China
关键词
lithium isotopes; standard solution; AGV-2; BHVO-2; IRMM-016; MC-ICP-MS; MC-ICP-MS; U-PB GEOCHRONOLOGY; WEATHERING PROCESSES; PERIDOTITE XENOLITHS; GEOLOGICAL-MATERIALS; OROGENIC ECLOGITES; ATOMIC-WEIGHT; LIGHT LI; FRACTIONATION; MANTLE;
D O I
10.1111/j.1755-6724.2012.00749.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Lithium separation technique for three reference materials has been established together with precise determination of lithium isotope using a Neptune multi collector-inductively coupled plasma mass spectrometry (MC-ICP-MS). The solutions of lithium element standard reference materials, potassium, calcium, sodium, magnesium and iron single element, were used to evaluate analytical methods applied. Three separate stages of ion-exchange chromatography were carried out using organic cation-exchange resin (AG 50W-X8). Lithium was enriched for the three stages using different eluants, which are 2.8 M HCl, 0.15 M HCl and 0.5 M HCl in 30% ethanol, respectively. The columns for the first and second stages are made of polypropylene, and those for the third stage are made of quartz. Total reagent volume for the entire chemical process was 35 mL for three reference materials. The recovery yielded for the three stages is 98.9101.2% with an average of 100.0%, 97.6101.9% with an average of 99.9%, and 99.8103.3% with an average of 100.6%, respectively. The precision of this technique is conservatively estimated to be +/- 0.721.04 parts per thousand (2 sigma population), which is similar to the precision obtained by different authors in different laboratories with MC-ICP-MS. The delta 7Li values (7Li/6Li relative to the IRMM-016 standard) determined for andesite (AGV-2) and basalt (BHVO-2) are 5.68 parts per thousand (n= 18), 4.33 parts per thousand (n= 18), respectively. The delta 7Li value (7Li/6Li relative to the L-SVEC standard) determined for IRMM-016 is 0.01 parts per thousand (n= 15). All these analytical results are in good agreement with those previously reported. In addition, the results for the same kinds of samples analyzed at the MLR Key Laboratory of Metallogeny and Mineral Assessment, Institute of Mineral Resources, Chinese Academy of Geological Sciences, are consistent with those obtained at the Plasma Laboratory, University of Maryland, within analytical uncertainty. According to these experiment results, it is concluded that this proposed procedure is a suitable method for determining the lithium isotopic composition of natural samples.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 50 条
  • [41] Silicon isotope measurement in zircon by laser ablation multiple collector inductively coupled plasma mass spectrometry
    Guitreau, Martin
    Gannoun, Abdelmouhcine
    Deng, Zhengbin
    Marin-Carbonne, Johanna
    Chaussidon, Marc
    Moynier, Frederic
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (08) : 1597 - 1606
  • [42] An analytical method for precise determination of the cadmium isotopic composition in plant samples using multiple collector inductively coupled plasma mass spectrometry
    Wei, Rongfei
    Guo, Qingjun
    Wen, Hanjie
    Yang, Junxing
    Peters, Marc
    Zhu, Chuanwei
    Ma, Jie
    Zhu, Guangxu
    Zhang, Hanzhi
    Tian, Liyan
    Wang, Chunyu
    Wan, Yingxin
    ANALYTICAL METHODS, 2015, 7 (06) : 2479 - 2487
  • [43] Sulfur Concentration in Geochemical Reference Materials by Solution Inductively Coupled Plasma-Mass Spectrometry
    Erdman, Monica E.
    Lee, Cin-Ty A.
    Yang, Wenbo
    Ingram, Lynn
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (01) : 51 - 60
  • [44] Accurate Determination of Lithium Isotopic Compositions in Geological Samples by Multi-collector Inductively Coupled Plasmon-Mass Spectrometry
    Zhang Jun-Wen
    Meng Jun-Lun
    Zhao Zhi-Qi
    Liu Cong-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (03) : 415 - 422
  • [45] Application of the isotope dilution technique for 93Zr determination in an irradiated cladding material by multiple collector-inductively coupled plasma mass spectrometry
    Chartier, F.
    Isnard, H.
    Degros, J. P.
    Faure, A. L.
    Frechou, C.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 270 (03) : 127 - 133
  • [46] Measurement of U and Pu isotope ratios in hair and nail samples using extraction chromatography and multi-collector inductively coupled plasma mass spectrometry
    Brown, J. N. W.
    Robertson, J. D.
    Brockman, J. D.
    TALANTA, 2014, 129 : 481 - 485
  • [47] Chemical Separation of Uranium and Precise Measurement of 234U/238U and 235U/238U Ratios in Soil Samples Using Multi Collector Inductively Coupled Plasma Mass Spectrometry
    Veerasamy, Nimelan
    Takamasa, Asako
    Murugan, Rajamanickam
    Kasar, Sharayu
    Aono, Tatsuo
    Inoue, Kazumasa
    Fukushi, Masahiro
    Sahoo, Sarata Kumar
    MOLECULES, 2020, 25 (09):
  • [48] High-precision magnesium isotope analysis of geological and environmental reference materials by multiple-collector inductively coupled plasma mass spectrometry
    Gao, Ting
    Ke, Shan
    Li, Ruiying
    Meng, Xu'nan
    He, Yongsheng
    Liu, Chengshuai
    Wang, Yang
    Li, Zijian
    Zhu, Jian-Ming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (08) : 767 - 777
  • [49] An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry
    Barling, Jane
    Weis, Dominique
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) : 653 - 662
  • [50] Comparison of thermal ionization mass spectrometry and Multiple Collector Inductively Coupled Plasma Mass Spectrometry for cesium isotope ratio measurements
    Isnard, H.
    Granet, M.
    Caussignac, C.
    Ducarme, E.
    Nonell, A.
    Tran, B.
    Chartier, F.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (11-12) : 1280 - 1286