Separation and Precise Measurement of Lithium Isotopes in Three Reference Materials Using Multi Collector-Inductively Coupled Plasma Mass Spectrometry

被引:26
|
作者
Tian Shihong [1 ,2 ]
Hou Zengqian [3 ]
Su Aina [4 ]
Hou Kejun [2 ]
Hu Wenjie [5 ]
Li Zhenzhen [6 ]
Zhao Yue [2 ]
Gao Yanguang [7 ]
Li Yanhe [2 ]
Yang Dan [2 ]
Yang Zhusen [2 ]
机构
[1] China Univ Geosci, Sch Earth Sci & Mineral Resources, Beijing 10083, Peoples R China
[2] Chinese Acad Geol Sci, Key Lab Metallogeny & Mineral Assessment, Minist Land & Resources, Inst Mineral Resources, Beijing 100037, Peoples R China
[3] Chinese Acad Geol Sci, Inst Geol, Beijing 100037, Peoples R China
[4] Chinese Acad Geol Sci, Inst Hydrogeol & Environm Geol, Shijiazhuang 050061, Hebei, Peoples R China
[5] Jiangxi Prov Inst Geol Survey, Nanchang 330030, Peoples R China
[6] Kunming Univ Sci & Technol, Kunming 650093, Yunnan, Peoples R China
[7] China Geol Survey, Beijing 100037, Peoples R China
关键词
lithium isotopes; standard solution; AGV-2; BHVO-2; IRMM-016; MC-ICP-MS; MC-ICP-MS; U-PB GEOCHRONOLOGY; WEATHERING PROCESSES; PERIDOTITE XENOLITHS; GEOLOGICAL-MATERIALS; OROGENIC ECLOGITES; ATOMIC-WEIGHT; LIGHT LI; FRACTIONATION; MANTLE;
D O I
10.1111/j.1755-6724.2012.00749.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Lithium separation technique for three reference materials has been established together with precise determination of lithium isotope using a Neptune multi collector-inductively coupled plasma mass spectrometry (MC-ICP-MS). The solutions of lithium element standard reference materials, potassium, calcium, sodium, magnesium and iron single element, were used to evaluate analytical methods applied. Three separate stages of ion-exchange chromatography were carried out using organic cation-exchange resin (AG 50W-X8). Lithium was enriched for the three stages using different eluants, which are 2.8 M HCl, 0.15 M HCl and 0.5 M HCl in 30% ethanol, respectively. The columns for the first and second stages are made of polypropylene, and those for the third stage are made of quartz. Total reagent volume for the entire chemical process was 35 mL for three reference materials. The recovery yielded for the three stages is 98.9101.2% with an average of 100.0%, 97.6101.9% with an average of 99.9%, and 99.8103.3% with an average of 100.6%, respectively. The precision of this technique is conservatively estimated to be +/- 0.721.04 parts per thousand (2 sigma population), which is similar to the precision obtained by different authors in different laboratories with MC-ICP-MS. The delta 7Li values (7Li/6Li relative to the IRMM-016 standard) determined for andesite (AGV-2) and basalt (BHVO-2) are 5.68 parts per thousand (n= 18), 4.33 parts per thousand (n= 18), respectively. The delta 7Li value (7Li/6Li relative to the L-SVEC standard) determined for IRMM-016 is 0.01 parts per thousand (n= 15). All these analytical results are in good agreement with those previously reported. In addition, the results for the same kinds of samples analyzed at the MLR Key Laboratory of Metallogeny and Mineral Assessment, Institute of Mineral Resources, Chinese Academy of Geological Sciences, are consistent with those obtained at the Plasma Laboratory, University of Maryland, within analytical uncertainty. According to these experiment results, it is concluded that this proposed procedure is a suitable method for determining the lithium isotopic composition of natural samples.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 50 条
  • [31] Simultaneous Measurement of Major,Trace Elements and Pb Isotopes in Silicate Glasses by Laser Ablation Quadrupole and Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Mengning Dai
    Zhi’an Bao
    Kaiyun Chen
    Chunlei Zong
    Honglin Yuan
    Journal of Earth Science, 2017, 28 (01) : 92 - 102
  • [32] Fast and precise boron isotopic analysis of carbonates and seawater using Nu Plasma II multi-collector inductively coupled plasma mass spectrometry and a simple sample introduction system
    Chen, Xin-Yang
    Teng, Fang-Zhen
    Catling, David C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (14) : 1169 - 1178
  • [33] Enhanced sensitivity in laser ablation multi-collector inductively coupled plasma mass spectrometry
    Cottle, John M.
    Burrows, Andrew J.
    Kylander-Clark, Andrew
    Freedman, Philip A.
    Cohen, Roy S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1700 - 1706
  • [34] Characterization of Geological Certified Reference Materials by Inductively Coupled Plasma-Mass Spectrometry
    Pradhan, Sonali
    Zhang, Jing
    Qu Jianguo
    Yun, Xue
    ANALYTICAL LETTERS, 2015, 48 (13) : 2136 - 2158
  • [35] Iron Isotopic Measurement using Large-Geometry High-Resolution Multi-Collector Inductively Coupled Plasma Mass Spectrometer
    Lei, Yvtian
    Li, Ming
    Wang, Zaicong
    Zhu, Yangtao
    Hu, Zhaochu
    Li, Yongsheng
    Chai, Xinna
    ATOMIC SPECTROSCOPY, 2022, 43 (03) : 214 - 222
  • [36] Improved nickel-corrected isotopic analysis of iron using high-resolution multi-collector inductively coupled plasma mass spectrometry
    Chen, Kai-Yun
    Yuan, Hong-Lin
    Liang, Peng
    Bao, Zhi-An
    Chen, Lu
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 421 : 196 - 203
  • [37] Improved in situ analysis of lead isotopes in low-Pb melt inclusions using laser ablation-multi-collector-inductively coupled plasma-mass spectrometry
    Yu, Hongxia
    Zhang, Yinhui
    Liu, Xijun
    Hong, Lubing
    Zhang, Le
    Xu, Jifeng
    Ren, Zhongyuan
    Deng, Faliang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (22)
  • [38] Measurement of uranium isotope ratios in Fukushima-accident contaminated soil samples using multi collector inductively coupled plasma mass spectrometry
    Murugan, R.
    Kavasi, N.
    Sahoo, S. K.
    Omori, Y.
    Sorimachi, A.
    Takahashi, H.
    Aono, T.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2021, 232
  • [39] Determination of Hf isotope ratios in zircon using multiple collector-inductively coupled plasma mass spectrometry equipped with laser ablation and desolvating nebulizer dual sample introduction system
    Kimura, Jun-Ichi
    Tani, Kenichiro
    Chang, Qing
    GEOCHEMICAL JOURNAL, 2012, 46 (01) : 1 - 12
  • [40] Characterization of Four Copper Materials for Application as Reference Materials for High Precision Copper Isotope Analysis by Laser Ablation Inductively Coupled Plasma Multi-Collector Mass Spectrometry
    Yang, Zhaoping
    Jackson, Simon Edward
    Skulski, Thomas
    FRONTIERS IN CHEMISTRY, 2021, 9