Near unity input displacement factor for voltage source PWM drives

被引:0
|
作者
Maswood, AI [1 ]
Wei, S [1 ]
Jianguo, Z [1 ]
机构
[1] Nanyang Technol Univ, Power Elect & Dr Lab, Sch EEE, Singapore 639798, Singapore
来源
2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3 | 2001年
关键词
PWM voltage source rectifiers; PWM-SHE; and high power factor;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
More and more PWM rectifiers are now used to replace traditional diode or thyristor types in AC drive systems. To minimize the switching frequency, while keeping the input current close to sinusoidal, this paper presents a topology composed of two identical front-end voltage source rectifiers in series and a three-winding transformer. This topology uses the transformer connection to remove the harmonics of the order 6k +/-1 (k = 1,3,5, ...). Additional harmonics lower than 23(rd) are eliminated by a suitable PWM-SHE switching pattern. Among known PWM switching patterns, the PWM-SHE produces the lowest switching losses, yet eliminates the required harmonics, The resulting converter system presents all the advantages associated with active front-end rectifiers. The main purpose is to ensure near unity power factor operation. A simple control structure is used. Simulation and experimental results confirm the feasibility and advantage of the proposed drive system.
引用
收藏
页码:1388 / 1392
页数:5
相关论文
共 50 条