Electrochemical Determination of Rifampicin Based on Its Oxidation Using Multi-Walled Carbon Nanotube-Modified Glassy Carbon Electrodes

被引:8
|
作者
Kul, Dilek [1 ]
机构
[1] Karadeniz Tech Univ, Dept Analyt Chem, Fac Pharm, Trabzon, Turkey
关键词
Rifampicin; voltammetry; multi-walled carbon nanotubes; glassy carbon electrode; pharmaceuticals; PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROPHOTOMETRIC DETERMINATION; PHARMACEUTICAL FORMULATIONS; HUMAN PLASMA; BLOOD SPOTS; HPLC METHOD; VALIDATION; PYRAZINAMIDE; COMPLEXATION; LEVOFLOXACIN;
D O I
10.4274/tjps.galenos.2019.33600
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: The aim of the study was to investigate the electrochemical behavior of rifampicin (RIF) in the anodic direction using multi-walled carbon nanotube (MWCNT)-modified glassy carbon electrodes. Materials and Methods: The anodic investigation of RIF was carried out with cyclic, differential pulse, and square wave voltammetry. A three-electrode system consisting of a glassy carbon electrode with a modification by MWCNTs as the working electrode, a platinum wire as the counter electrode, and an Ag/AgCl electrode as reference was used for the experiments. Results: The anodic process of RIF was irreversible and diffusion controlled. Linear responses were obtained between 0.04 and 10 mu M for both techniques in acetate buffer (pH 3.5) as supporting electrolyte. The limit of detection values were 7.51 and 11.3 nM for differential pulse and square wave voltammetry, respectively. The repeatability, reproducibility, precision, and accuracy of the proposed methods were also investigated. Determination of RIF was carried out on its pharmaceutical dosage forms and the results were compared with those from other electrochemical sensors and the liquid chromatographic and spectrophotometric methods in the literature. Conclusion: These validated techniques provided selective, rapid, sensitive, precise, and cheap determination of RIF as alternative techniques to the liquid chromatographic and spectrophotometric methods in therapeutic drug monitoring.
引用
收藏
页码:398 / 407
页数:10
相关论文
共 50 条
  • [21] Electrochemical sensor for the determination of enterotoxigenic Escherichia coli in swine feces using glassy carbon electrodes modified with multi-walled carbon nanotubes
    Viviana Tarditto, Lorena
    Javier Arevalo, Fernando
    Alicia Zon, Maria
    Garcia Ovando, Hugo
    Roberto Vettorazzi, Nelio
    Fernandez, Hector
    MICROCHEMICAL JOURNAL, 2016, 127 : 220 - 225
  • [22] Voltammetric determination of folic acid with a multi-walled carbon nanotube-modified gold electrode
    Wei, SH
    Zhao, FQ
    Xu, ZY
    Zeng, BZ
    MICROCHIMICA ACTA, 2006, 152 (3-4) : 285 - 290
  • [23] Electrochemical oxidation of theophylline at multi-wall carbon nanotube modified glassy carbon electrodes
    Zhu, YH
    Zhang, ZL
    Pang, DW
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 581 (02) : 303 - 309
  • [24] Electrochemical Oxidation of Sulfamethazine on Multi-Walled Nanotube Film Coated Glassy Carbon Electrode
    Fotouhi, Lida
    Zabeti, Masoumeh
    JOURNAL OF NANOSTRUCTURES, 2014, 4 (02) : 161 - 166
  • [25] Electrochemical properties and the determination of nicotine at a multi-walled carbon nanotubes modified glassy carbon electrode
    Huayu Xiong
    Yunfei Zhao
    Peng Liu
    Xiuhua Zhang
    Shengfu Wang
    Microchimica Acta, 2010, 168 : 31 - 36
  • [26] Electrochemical properties and the determination of nicotine at a multi-walled carbon nanotubes modified glassy carbon electrode
    Xiong, Huayu
    Zhao, Yunfei
    Liu, Peng
    Zhang, Xiuhua
    Wang, Shengfu
    MICROCHIMICA ACTA, 2010, 168 (1-2) : 31 - 36
  • [27] Multi-walled carbon nanotube modified glassy carbon electrode as curcumin sensor
    Mustafa Cittan
    Esra Altuntaş
    Ali Çelik
    Monatshefte für Chemie - Chemical Monthly, 2020, 151 : 881 - 888
  • [28] Development of electrochemical method for the determination of olaquindox using multi-walled carbon nanotubes modified glassy carbon electrode
    Xu, Tianci
    Zhang, Lei
    Yang, Jichun
    Li, Na
    Yang, Lijun
    Jiang, Xiaoqing
    TALANTA, 2013, 109 : 185 - 190
  • [29] ELECTROOXIDATION OF DNA AT GLASSY CARBON ELECTRODES MODIFIED WITH MULTI-WALLED CARBON NANOTUBES WITH DIFFERENT OXIDATION DEGREE
    Canete-Rosales, Paulina
    Alvarez-Lueje, Alejandro
    Bollo, Soledad
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2014, 59 (02): : 2494 - 2497
  • [30] Bilirubin oxidase bound to multi-walled carbon nanotube-modified gold
    Schubert, Kirsten
    Goebel, Gero
    Lisdat, Fred
    ELECTROCHIMICA ACTA, 2009, 54 (11) : 3033 - 3038