AIM: To compare the diagnostic performance of angio-computed tomography (CT) with multidetector CT (MDCT) in the detection and location for insulinomas. MATERIALS AND METHODS: From April 2015 to April 2018, 60 consecutive patients who underwent MDCT and angio-CT for clinically suspected insulinomas were identified retrospectively. The CT attenuation values of tumours, normal pancreatic parenchyma, and tumour- to-pancreas contrast were measured quantitatively in the arterial phase (AP) and portal venous phase (PVP) of both methods by two radiologists with interobserver agreement. The detection sensitivity and localisation accuracy were calculated based on surgical and pathological findings, which are the reference standard, and compared between both methods using the chi-square test. Receiver operating characteristic (ROC) analysis was performed to compare diagnostic performance. RESULTS: Fifty-four patients with insulinoma with a mean age of 53.8 years old (range 21 -69 years) were reviewed. The detection sensitivity and location accuracy were 68.5%, 58.3% for MDCT and 94.4%, 90.7% for angio-CT, respectively; the detection sensitivity and location accuracy of angio-CT were significantly higher than those obtained with MDCT (p < 0.05). The mean tumour-to-pancreas attenuations were 105.1 +/- 25 HU in the AP of MDCT and 285 +/- 48.7 HU in the AP of angio-CT. There were significant differences in the tumour-to-pancreas contrast in the AP between MDCT and angio-CT (p < 0.05). The Az values were 0.93 and 0.84 for the AP of angio-CT and MDCT, 0.62 and 0.54 for the PVP. The AP of angio-CT was significantly more accurate for insulinoma detection (p < 0.05). CONCLUSION: Angio-CT produces higher tumour conspicuity and is superior in the detection and location of insulinomas compared to MDCT. (C) 2020 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:796.e11 / 796.e16
页数:6
相关论文
共 50 条
[31]   Detection of Coalescent Acute Mastoiditis on MRI in Comparison with CT [J].
Saat, R. ;
Kurdo, G. ;
Laulajainen-Hongisto, A. ;
Markkola, A. ;
Jero, J. .
CLINICAL NEURORADIOLOGY, 2021, 31 (03) :589-597
[32]   Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation [J].
Addley, H. C. ;
Griffin, N. ;
Shaw, A. S. ;
Mannelli, L. ;
Parker, R. A. ;
Aitken, S. ;
Wood, H. ;
Davies, S. ;
Alexander, G. J. ;
Lomas, D. J. .
CLINICAL RADIOLOGY, 2011, 66 (04) :349-356
[33]   Pulmonary Artery Imaging in Patients with Chronic Thromboembolic Pulmonary Hypertension: Comparison of Cone-Beam CT and 64-Row. Multidetector CT [J].
Hinrichs, Jan B. ;
von Falck, Christian ;
Hoeper, Marius M. ;
Olsson, Karen M. ;
Wacker, Frank K. ;
Meyer, Bernhard C. ;
Renne, Julius .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (03) :361-368
[34]   Gastric subepithelial masses: evaluation of multidetector CT (multiplanar reconstruction and virtual gastroscopy) versus endoscopic ultrasonography [J].
Okten, Riza Sarper ;
Kacar, Sabite ;
Kucukay, Fahrettin ;
Sasmaz, Nurgul ;
Cumhur, Turhan .
ABDOMINAL IMAGING, 2012, 37 (04) :519-530
[35]   Focal hepatic nodules after transcatheter oily chemoembolization; Detection with spiral CT versus conventional CT [J].
Choi, BI ;
Shin, YM ;
Han, JK ;
Chung, JW ;
Park, JH ;
Han, MC .
ABDOMINAL IMAGING, 1996, 21 (01) :33-36
[36]   CT versus MR Techniques in the Detection of Cervical Artery Dissection [J].
Hanning, Uta ;
Sporns, Peter B. ;
Schmiedel, Meilin ;
Ringelstein, Erich B. ;
Heindel, Walter ;
Wiendl, Heinz ;
Niederstadt, Thomas ;
Dittrich, Ralf .
JOURNAL OF NEUROIMAGING, 2017, 27 (06) :607-612
[37]   Intraindividual Comparison of Gadoxetate Disodium-enhanced MR Imaging and 64-Section Multidetector CT in the Detection of Hepatocellular Carcinoma in Patients with Cirrhosis [J].
Di Martino, Michele ;
Marin, Daniele ;
Guerrisi, Antonino ;
Baski, Mahbubeh ;
Galati, Francesca ;
Rossi, Massimo ;
Brozzetti, Stefania ;
Masciangelo, Raffaele ;
Passariello, Roberto ;
Catalano, Carlo .
RADIOLOGY, 2010, 256 (03) :806-816
[38]   Detection of Insulinomas Using Dual-Time-Point 68Ga-DOTA-Exendin 4 PET/CT [J].
Michalski, Kerstin ;
Laubner, Katharina ;
Stoykow, Christian ;
Omrane, Mohamed Aymen ;
Maecke, Helmut R. ;
Seufert, Jochen ;
Goetz, Christian ;
Meyer, Philipp T. ;
Ruf, Juri .
CLINICAL NUCLEAR MEDICINE, 2020, 45 (07) :519-524
[39]   Multidetector helical CT in the evaluation of acute small bowel obstruction: Comparison of non-enhanced (no oral, rectal or IV contrast) and IV enhanced CT [J].
Atri, Mostafa ;
McGregor, Caitlin ;
McInnes, Mathew ;
Power, Niall ;
Rahnavardi, Katayoun ;
Law, Calvin ;
Kiss, Alex .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) :135-140
[40]   Malignant versus benign nodules at CT screening for lung cancer: Comparison of thin-section CT findings [J].
Li, F ;
Sone, S ;
Abe, H ;
MacMhon, H ;
Doi, K .
RADIOLOGY, 2004, 233 (03) :793-798