Comparison of angio-CT versus multidetector CT in the detection and location for insulinomas

被引:3
作者
Fu, J. [1 ]
Zhang, J. [1 ]
Wang, Y. [1 ]
Yan, J. [1 ]
Yuan, K. [1 ]
Wang, M. [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Intervent Radiol, 28 Fuxing Rd, Beijing 100853, Peoples R China
关键词
NEUROENDOCRINE TUMORS; DIAGNOSIS; LOCALIZATION; FREQUENCY; PANCREAS;
D O I
10.1016/j.crad.2020.05.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare the diagnostic performance of angio-computed tomography (CT) with multidetector CT (MDCT) in the detection and location for insulinomas. MATERIALS AND METHODS: From April 2015 to April 2018, 60 consecutive patients who underwent MDCT and angio-CT for clinically suspected insulinomas were identified retrospectively. The CT attenuation values of tumours, normal pancreatic parenchyma, and tumour- to-pancreas contrast were measured quantitatively in the arterial phase (AP) and portal venous phase (PVP) of both methods by two radiologists with interobserver agreement. The detection sensitivity and localisation accuracy were calculated based on surgical and pathological findings, which are the reference standard, and compared between both methods using the chi-square test. Receiver operating characteristic (ROC) analysis was performed to compare diagnostic performance. RESULTS: Fifty-four patients with insulinoma with a mean age of 53.8 years old (range 21 -69 years) were reviewed. The detection sensitivity and location accuracy were 68.5%, 58.3% for MDCT and 94.4%, 90.7% for angio-CT, respectively; the detection sensitivity and location accuracy of angio-CT were significantly higher than those obtained with MDCT (p < 0.05). The mean tumour-to-pancreas attenuations were 105.1 +/- 25 HU in the AP of MDCT and 285 +/- 48.7 HU in the AP of angio-CT. There were significant differences in the tumour-to-pancreas contrast in the AP between MDCT and angio-CT (p < 0.05). The Az values were 0.93 and 0.84 for the AP of angio-CT and MDCT, 0.62 and 0.54 for the PVP. The AP of angio-CT was significantly more accurate for insulinoma detection (p < 0.05). CONCLUSION: Angio-CT produces higher tumour conspicuity and is superior in the detection and location of insulinomas compared to MDCT. (C) 2020 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:796.e11 / 796.e16
页数:6
相关论文
共 50 条
  • [21] Enhancement patterns of hepatocellular carcinomas on multiphasic multidetector row CT: comparison with pathological differentiation
    Lee, J. H.
    Lee, J. M.
    Kim, S. J.
    Baek, J. H.
    Yun, S. H.
    Kim, K. W.
    Han, J. K.
    Choi, B. I.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1017) : E573 - E583
  • [22] Vascular malformation of the jejunum presenting as obscure gastrointestinal haemorrhage: detection with multidetector CT angiography
    Lal, H.
    Neyaz, Z.
    Singh, R. K.
    Mohindra, S.
    SINGAPORE MEDICAL JOURNAL, 2010, 51 (06) : E103 - E106
  • [23] Incidental Detection of Nutcracker Phenomenon on Multidetector CT in an Asymptomatic Population: Prevalence and Associated Findings
    Grimm, Lars J.
    Engstrom, Bjorn I.
    Nelson, Rendon C.
    Kim, Charles Y.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 415 - 418
  • [24] Comparison of CT, MRI and CT during arterial portography in the detection of malignant hepatic lesions
    Kehagias, D
    Metafa, A
    Hatziioannou, A
    Mourikis, D
    Vourtsi, A
    Prahalias, A
    Smyrniotis, V
    Gouliamos, A
    Vlahos, L
    HEPATO-GASTROENTEROLOGY, 2000, 47 (35) : 1399 - 1403
  • [25] Value of hepatic arterial phase CT versus lipiodol ultrafluid CT in the detection of hepatocellular carcinoma
    Colagrande, S
    Fargnoli, R
    Dal Pozzo, F
    Bindi, A
    Rega, L
    Villari, N
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (06) : 878 - 883
  • [26] Comparison between blinded and partially blinded detection of gastric cancer with multidetector CT using surgery and endoscopic submucosal dissection as reference standards
    Kim, H. J.
    Lee, D. H.
    Ko, Y. T.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (992) : 674 - 682
  • [27] Three-dimensional contrast-enhanced magnetic resonance venography for detection of renal vein thrombosis: comparison with multidetector CT venography
    Zhang, Long Jiang
    Wu, Xinsheng
    Yang, Gui Fen
    Tang, Chun Xiang
    Luo, Song
    Zhou, Chang Sheng
    Ji, Xue Man
    Lu, Guang Ming
    ACTA RADIOLOGICA, 2013, 54 (10) : 1125 - 1131
  • [28] Comparison of diffusion-weighted MR imaging and multidetector-row CT in the detection of liver metastases in patients operated for pancreatic cancer
    Holzapfel, Konstantin
    Reiser-Erkan, Carolin
    Fingerle, Alexander A.
    Erkan, Merd
    Eiber, Matthias J.
    Rummeny, Ernst J.
    Friess, Helmut
    Kleeff, Joerg
    Gaa, Jochen
    ABDOMINAL IMAGING, 2011, 36 (02): : 179 - 184
  • [29] Comparison of MRI and CT Scan for the Detection of Liver Cancer
    Liu, Yuangao
    Chen, Changxiong
    Liu, Longjin
    Li, Yuhui
    CURRENT MEDICAL IMAGING, 2023, 19 (09) : 995 - 1004
  • [30] A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT
    Iwasawa, Tae
    Matsumoto, Sumiaki
    Aoki, Takatoshi
    Okada, Fumito
    Nishimura, Yoshihiro
    Yamagata, Hitoshi
    Ohno, Yoshiharu
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 76 - 83