Comparison of angio-CT versus multidetector CT in the detection and location for insulinomas

被引:3
|
作者
Fu, J. [1 ]
Zhang, J. [1 ]
Wang, Y. [1 ]
Yan, J. [1 ]
Yuan, K. [1 ]
Wang, M. [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Intervent Radiol, 28 Fuxing Rd, Beijing 100853, Peoples R China
关键词
NEUROENDOCRINE TUMORS; DIAGNOSIS; LOCALIZATION; FREQUENCY; PANCREAS;
D O I
10.1016/j.crad.2020.05.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare the diagnostic performance of angio-computed tomography (CT) with multidetector CT (MDCT) in the detection and location for insulinomas. MATERIALS AND METHODS: From April 2015 to April 2018, 60 consecutive patients who underwent MDCT and angio-CT for clinically suspected insulinomas were identified retrospectively. The CT attenuation values of tumours, normal pancreatic parenchyma, and tumour- to-pancreas contrast were measured quantitatively in the arterial phase (AP) and portal venous phase (PVP) of both methods by two radiologists with interobserver agreement. The detection sensitivity and localisation accuracy were calculated based on surgical and pathological findings, which are the reference standard, and compared between both methods using the chi-square test. Receiver operating characteristic (ROC) analysis was performed to compare diagnostic performance. RESULTS: Fifty-four patients with insulinoma with a mean age of 53.8 years old (range 21 -69 years) were reviewed. The detection sensitivity and location accuracy were 68.5%, 58.3% for MDCT and 94.4%, 90.7% for angio-CT, respectively; the detection sensitivity and location accuracy of angio-CT were significantly higher than those obtained with MDCT (p < 0.05). The mean tumour-to-pancreas attenuations were 105.1 +/- 25 HU in the AP of MDCT and 285 +/- 48.7 HU in the AP of angio-CT. There were significant differences in the tumour-to-pancreas contrast in the AP between MDCT and angio-CT (p < 0.05). The Az values were 0.93 and 0.84 for the AP of angio-CT and MDCT, 0.62 and 0.54 for the PVP. The AP of angio-CT was significantly more accurate for insulinoma detection (p < 0.05). CONCLUSION: Angio-CT produces higher tumour conspicuity and is superior in the detection and location of insulinomas compared to MDCT. (C) 2020 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:796.e11 / 796.e16
页数:6
相关论文
共 50 条
  • [1] The Value of Hybrid Angio-CT in Preoperative Detection and Localization of Insulinomas: A Single-Center Retrospective Study
    Fu, Jinxin
    Liu, Fengyong
    Yuan, Kai
    Yan, Jieyu
    Wang, Yan
    Zhang, Jinlong
    Yuan, Bing
    Wang, Maoqiang
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (04) : 633 - 638
  • [2] The Value of Hybrid Angio-CT in Preoperative Detection and Localization of Insulinomas: A Single-Center Retrospective Study
    Jinxin Fu
    Fengyong Liu
    Kai Yuan
    Jieyu Yan
    Yan Wang
    Jinlong Zhang
    Bing Yuan
    Maoqiang Wang
    CardioVascular and Interventional Radiology, 2018, 41 : 633 - 638
  • [4] The value of multidetector-row CT in the preoperative detection of pancreatic insulinomas
    Liu, Y.
    Song, Q.
    Jin, H. T.
    Lin, X. Z.
    Chen, K. M.
    RADIOLOGIA MEDICA, 2009, 114 (08): : 1232 - 1238
  • [5] Characterization of Incidental Liver Lesions: Comparison of Multidetector CT versus Ultrasonography
    Osman, Hanady Elyas
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2023, 13 (01) : 84 - 90
  • [6] Perforated versus nonperforated acute appendicitis: Accuracy of multidetector CT detection
    Bixby, Sarah D.
    Lucey, Brian C.
    Soto, Jorge A.
    Theyson, Jens M.
    Ozonoff, Al
    Varghese, Jose C.
    RADIOLOGY, 2006, 241 (03) : 780 - 786
  • [7] IMPROVED DETECTION OF SMALL INSULINOMAS WITH INTRAVENOUS DYNAMIC CT
    KUROSAKI, Y
    KURAMOTO, K
    MURATA, S
    ITAI, Y
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) : 588 - 589
  • [8] Conventional High-resolution CT Versus Contiguous Multidetector CT in the Detection of Bronchiolitis Obliterans Syndrome in Lung Transplant Recipients
    Dodd, Jonathan D.
    de Jong, Pim. A.
    Levy, Robert D.
    Coxson, Harvey O.
    Mayo, John R.
    JOURNAL OF THORACIC IMAGING, 2008, 23 (04) : 235 - 243
  • [9] Detection of Pulmonary Hypertension with Multidetector CT and Echocardiography Alone and in Combination
    Devaraj, Anand
    Wells, Athol U.
    Meister, Mark G.
    Corte, Tamera J.
    Wort, Stephen J.
    Hansell, David M.
    RADIOLOGY, 2010, 254 (02) : 609 - 616
  • [10] Comparison of Multidetector CT and Endoscopic Ultrasonography in Malignant Pancreatic Mass Lesions
    Arabul, Mahmut
    Karakus, Funda
    Alper, Emrah
    Kandemir, Altay
    Celik, Mustafa
    Karakus, Volkan
    Yucel, Kamil
    Unsal, Belkis
    HEPATO-GASTROENTEROLOGY, 2012, 59 (117) : 1599 - 1603