A generic approach for the detection of whole Listeria monocytogenes cells in contaminated samples using surface plasmon resonance

被引:113
作者
Leonard, P
Hearty, S
Quinn, J
O'Kennedy, R [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[2] Dublin City Univ, NCSR, Dublin 9, Ireland
关键词
surface plasmon resonance (SPR); subtractive inhibition assay; Listeria monocytogenes;
D O I
10.1016/j.bios.2003.11.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The opportunistic food pathogen Listeria monocytogenes is of great concern to the food industry and its rapid detection is of major importance. This paper describes the detection of L. monocytogenes with a polyclonal antibody by means of a new subtractive inhibition assay using a BIAcore 3000 biosensor. Incubating L. monocytogenes cells and antibody for a short period of time, followed by subsequent separation of free unbound antibody with a stepwise centrifugation process, allowed the detection of 1 X 10(5) L. monocytogenes cells/ml in less than 30 ruin. Free antibody was passed over an anti-Fab ligand-coated sensor chip surface with the generated response being inversely proportional to the inhibiting cell concentration. The method was simple, rapid and needed minimum sample preparation. This assay format has the potential for the quick and sensitive detection of pathogens with limited sample handling and preparation. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 24 条
  • [1] Development of surface plasmon resonance-based immunoassay for aflatoxin B1
    Daly, SJ
    Keating, GJ
    Dillon, PP
    Manning, BM
    O'Kennedy, R
    Lee, HA
    Morgan, MRA
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (11) : 5097 - 5104
  • [2] Immunoassay for the determination of morphine-3-glucuronide using a surface plasmon resonance-based biosensor
    Dillon, PP
    Daly, SJ
    Manning, BM
    O'Kennedy, R
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) : 217 - 227
  • [3] Doganay M, 2003, FEMS IMMUNOL MED MIC, V1485, P1
  • [4] Donnelly CW, 2001, NUTR REV, V59, P183, DOI 10.1111/j.1753-4887.2001.tb07011.x
  • [5] Development of ELISA and sensor-based assays for the detection of ethynyl estradiol in bile
    Fitzpatick, J
    Manning, BM
    O'Kennedy, R
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 2003, 15 (01) : 55 - 64
  • [6] Applications and recent developments in the use of antibodies for analysis
    Fitzpatrick, J
    Fanning, L
    Hearty, S
    Leonard, P
    Manning, BM
    Quinn, JG
    O'Kennedy, R
    [J]. ANALYTICAL LETTERS, 2000, 33 (13) : 2563 - 2609
  • [7] Detection of Escherichia coli O157:H7 using a surface plasmon resonance biosensor
    Fratamico, PM
    Strobaugh, TP
    Medina, MB
    Gehring, AG
    [J]. BIOTECHNOLOGY TECHNIQUES, 1998, 12 (07) : 571 - 576
  • [8] HAINES J, 1995, DETECTION FOOD BORNE, P31
  • [9] HOF H, 2003, FEMS IMMUNOL MED MIC, V1489, P1
  • [10] Biosensors for detection of pathogenic bacteria
    Ivnitski, D
    Abdel-Hamid, I
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (07) : 599 - 624