Do Ion Levels in Metal-on-metal Hip Resurfacing Differ From Those in Metal-on-metal THA at Long-term Followup?

被引:21
作者
Savarino, Lucia [1 ]
Cadossi, Matteo [2 ]
Chiarello, Eugenio [2 ]
Baldini, Nicola [1 ,3 ]
Giannini, Sandro [2 ,3 ]
机构
[1] Rizzoli Orthopaed Inst, Lab Orthopaed Pathophysiol & Regenerat Med, I-40136 Bologna, Italy
[2] Rizzoli Orthopaed Inst, Dept Orthopaed & Traumatol 1, I-40136 Bologna, Italy
[3] Univ Bologna, Bologna, Italy
关键词
TOTAL JOINT REPLACEMENT; LARGE-DIAMETER METAL; PRIMARY OSTEOARTHRITIS; SURFACE REPLACEMENT; IN-VITRO; ARTHROPLASTY; RELEASE; CORROSION; CHROMIUM; COBALT;
D O I
10.1007/s11999-013-2981-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metal-on-metal hip resurfacing arthroplasty (MOM HR) has become an established alternative to traditional metal-on-metal total hip arthroplasty (MOM THA) for younger, more active patients. Nevertheless, concerns remain regarding wear and corrosion of the bearing surfaces and the resulting systemic metal ion distribution. We therefore asked whether (1) serum ion concentrations in patients with MOM HR at the time of long-term followup were higher than concentrations in a control population with no hip implants; (2) the ion concentrations in patients with MOM HR were different from those in patients with MOM THA; and (3) sex would influence ion levels with regard to implant type. The MOM HR and MOM THA groups consisted of 25 patients (evaluated at a minimum of 96 months) and 16 patients (evaluated at a minimum of 106 months), respectively. Forty-eight healthy donors were recruited for reference values. Cobalt, chromium, nickel, and molybdenum were measured by furnace graphite atomic absorption spectrophotometry. Ion concentrations of cobalt, chromium, and molybdenum in MOM HR were higher than in controls. Chromium and cobalt release were higher in MOM HR than in MOM THA. The sex-based analysis showed the difference was because women had higher concentrations in the MOM HR group than in the MOM THA group, whereas there was no difference between the men in the two groups. In MOM HR, high metal ion release persists for the long term. Consequently, it is important to implement strict biomonitoring for patients who have received these implants. The sustained high levels of chromium in females within the MOM HR group are concerning and merits strong consideration when choosing implants in this patient group. Level III, therapeutic study. See the Instructions for Authors online for a complete description of level of evidence.
引用
收藏
页码:2964 / 2971
页数:8
相关论文
共 48 条
[1]   TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[2]   Background of metal-on-metal resurfacing [J].
Amstutz, HC ;
Le Duff, MJ .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :85-94
[3]   The wear pattern in metal-on-metal hip prostheses [J].
Anissian, HL ;
Stark, A ;
Good, V ;
Dahlstrand, H ;
Clarke, IC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (06) :673-678
[4]   2011 Marshall Urist Young Investigator Award When to Release Patients to High-impact Activities after Hip Resurfacing [J].
Bedigrew, Katherine M. ;
Ruh, Erin L. ;
Zhang, Qin ;
Clohisy, John C. ;
Barrack, Robert L. ;
Nunley, Ryan M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) :299-306
[5]  
Bisseling P, 2011, ACTA ORTHOP, V82, P161, DOI [10.3109/17453674.2011.625533, 10.3109/17453674.2011.566140]
[6]   A benign psoas mass following metal-on-metal resurfacing of the hip [J].
Boardman, DR ;
Middleton, FR ;
Kavanagh, TG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (03) :402-404
[7]   Italian network for human biomonitoring of metals: preliminary results from two Regions [J].
Bocca, Beatrice ;
Mattei, Daniela ;
Pino, Anna ;
Alimonti, Alessandro .
ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2010, 46 (03) :259-265
[8]   Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity [J].
Bowsher, JG ;
Hussain, A ;
Williams, PA ;
Shelton, JC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :279-287
[9]   IN-VIVO TRANSPORT AND EXCRETION OF CORROSION PRODUCTS FROM ACCELERATED ANODIC CORROSION OF POROUS-COATED F75 ALLOY [J].
BROWN, SA ;
ZHANG, K ;
MERRITT, K ;
PAYER, JH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (08) :1007-1017
[10]   Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty [J].
Clarke, MT ;
Lee, PTH ;
Arora, A ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :913-917