Unstable Intertrochanteric Femur Fractures: Is There a Consensus on Definition and Treatment in Germany?

被引:88
|
作者
Knobe, Matthias [1 ]
Gradl, Gertraud [1 ]
Ladenburger, Andreas [2 ]
Tarkin, Ivan S. [3 ]
Pape, Hans-Christoph [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Orthopaed Trauma, Fac Med, D-52074 Aachen, Germany
[2] Univ Wurzburg, Dept Orthopaed Surg, Orthopaed Ctr Musculoskeletal Res, D-97070 Wurzburg, Germany
[3] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
关键词
SLIDING HIP SCREW; TROCHANTERIC FEMORAL FRACTURES; PERCUTANEOUS COMPRESSION PLATE; INTRAMEDULLARY FIXATION; INTERNAL-FIXATION; PROXIMAL FEMUR; LOCKING NAIL; LAG SCREW; FAILURE; CLASSIFICATION;
D O I
10.1007/s11999-013-2834-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Extramedullary and intramedullary implants have improved in recent years, although consensus is lacking concerning the definition and classification of unstable intertrochanteric fractures, with uncertainties regarding treatment. We conducted a national survey of practicing chairpersons of German institutions to determine current perspectives and perceptions of practice in the diagnosis, management, and surgical treatment of unstable intertrochanteric fractures. Between January and February 2010, we emailed 575 German chairpersons of trauma and/or orthopaedic departments, asking them to complete a 26-question web-based survey regarding three broad domains: fracture classification and instability criteria, implants and surgical treatment algorithms, and timing of operations. Response rate was 42%. There was a clear preference for use of the AO/OTA fracture classification with geographic variations. Absence of medial support was considered the main criterion for fracture instability (84%), whereas a broken lateral wall and detached greater trochanter were considered by 4% and 5% of the respondents, respectively, to determine instability. Two percent routinely fixed unstable intertrochanteric fractures with extramedullary devices. Ninety-eight percent of German hospitals reportedly perform surgery within 24 hours after admission. Time to surgery was dependent on hospital level, with more direct surgeries in Level I hospitals. Despite varying opinions in the literature in recent years, we found some instability criteria (lateral wall breach, a detached greater trochanter) played a minor role in defining an unstable intertrochanteric fracture pattern. Despite recent meta-analyses suggesting clinical equivalence of intra- and extramedullary implants, few respondents routinely treat unstable intertrochanteric fractures with extramedullary plates. Additional studies are required to specify the influence of fracture characteristics on complication rate and function and to establish a classification system with clear treatment recommendations for unstable intertrochanteric fractures.
引用
收藏
页码:2831 / 2840
页数:10
相关论文
共 50 条
  • [1] Biomechanical analysis of the cephalomedullary nail versus the trochanteric stabilizing plate for unstable intertrochanteric femur fractures
    Walmsley, David
    Nicayenzi, Bruce
    Kuzyk, Paul R. T.
    Machin, Alan
    Bougherara, Habiba
    Schemitsch, Emil H.
    Zdero, Radovan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (12) : 1133 - 1140
  • [2] Unstable intertrochanteric femur fractures in geriatric patients treated with the DLT trochanteric nail
    Temiz, Aytun
    Durak, Aslihan
    Atici, Teoman
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S41 - S46
  • [3] Potentially unstable intertrochanteric fractures
    Im, GI
    Shin, YW
    Song, YJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (01) : 5 - 9
  • [4] Locked plating versus cephalomedullary nailing of unstable intertrochanteric femur fractures
    Streubel P.N.
    Moustoukas M.
    Obremskey W.T.
    European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (4) : 385 - 390
  • [5] Functional and radiological comparison of three cephalomedullary nails with different designs used in the treatment of unstable intertrochanteric femur fractures of elderly
    Yapici, Furkan
    Ucpunar, Hanifi
    Gur, Volkan
    Onac, Osman
    Alpay, Yakup
    Karakose, Resit
    Camurcu, Yalkin
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2022, 28 (05): : 668 - 677
  • [6] Biomechanical study of extramedullary and intramedullary fixation in the treatment of unstable intertrochanteric reversed-tilt fractures of the femur
    Lu, Guo-Liang
    Li, Song-Jun
    Li, Wen-Xue
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (04)
  • [7] Is the Best Plate a Nail? A Review of 3230 Unstable Intertrochanteric Fractures of the Proximal Femur
    Tucker, Adam
    Donnelly, Kevin J.
    Rowan, Clare
    McDonald, Sinead
    Foster, Andrew P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (02) : 53 - 60
  • [8] Biomechanical Comparison of Three Different Intramedullary Nails for Fixation of Unstable Basicervical Intertrochanteric Fractures of the Proximal Femur: Experimental Studies
    Kwak, Dae-Kyung
    Kim, Won-Hyeon
    Lee, Sung-Jae
    Rhyu, Sang-Hyun
    Jang, Chul-Young
    Yoo, Je-Hyun
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [9] Stability of Intertrochanteric Femur Fractures
    Ricci, William M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (10S) : S1 - S4
  • [10] Proximal Femur Bionic Nail (PFBN): A Panacea for Unstable Intertrochanteric Femur Fracture
    Zhang, Kaixuan
    Chen, Wei
    Zhang, Yingze
    ENGINEERING, 2024, 37 : 152 - 158