Atomic force microscopy and nanoindentation investigation of polydimethylsiloxane elastomeric substrate compliancy for various sputtered thin film morphologies

被引:9
|
作者
Maji, Debashis [1 ]
Das, Soumen [2 ]
机构
[1] VIT Univ, Sch Elect Engn SENSE, Dept Sensor & Biomed Technol, Vellore 632014, Tamil Nadu, India
[2] Indian Inst Technol, Sch Med Sci & Technol, Kharagpur 721302, W Bengal, India
关键词
flexible bioelectronics; PDMS elastomer; Young's modulus; adhesion force; atomic force microscopy; nanoindentation; ORGANIC SOLAR-CELLS; ELASTIC-MODULUS; IN-VIVO; PDMS; POLYMER; PLASMA; SENSOR; AFM; POLY(DIMETHYLSILOXANE); DISCHARGE;
D O I
10.1002/jbm.a.36283
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Crack free electrically continuous metal thin films over soft elastomeric substrates play an integral part in realization of modern day flexible bioelectronics and biosensors. Under nonoptimized deposition conditions, delamination, and/or cracking of the top film as well as the underlying soft substrate hinders optimal performance of these devices. Hence it is very important to understand and control not only the various deposition factors like power, time, or deposition pressure but also investigate the various interfacial physics playing a critical role in assuring thin film adhesion and substrate compliancy. In the present study, various nanomechanical information of the underlying substrate, namely, crack profile, average roughness, Young's modulus, and adhesion force were studied for uncracked and cracked polydimethylsiloxane (PDMS) surfaces along with pristine and conventional plasma treated PDMS samples as control. Quantification of the above parameters were done using three-dimensional surface profiler, scanning electron microscopy, nanoindentation, and atomic force microscopy techniques to elucidate the modulus range, average roughness, and adhesion force. Comparative analysis with control revealed remarkable similarity between increased modulus values, increased surface roughness, and reduced adhesion force accounting for reduced substrate compliancy and resulting in film cracking or buckling which are critical for development of various bioflexible devices. (c) 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 725-737, 2018.
引用
收藏
页码:725 / 737
页数:13
相关论文
共 50 条
  • [31] SURFACE MORPHOLOGIES OF BATIO3 THIN-FILMS BY ATOMIC-FORCE MICROSCOPY
    YOON, YS
    YOON, YK
    LEE, JY
    YOM, SS
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1994, 33 (7A): : 4075 - 4079
  • [33] Scanning tunneling microscopy and atomic force microscopy investigation of organic tetracyanoquinodimethane thin films
    Gao, HJ
    Zhang, HX
    Xue, ZQ
    Pang, SJ
    JOURNAL OF MATERIALS RESEARCH, 1997, 12 (08) : 1942 - 1945
  • [34] Scanning Tunneling Microscopy and Atomic Force Microscopy Investigation of Organic Tetracyanoquinodimethane Thin Films
    H. J. Gao
    H. X. Zhang
    Z. Q. Xue
    S. J. Pang
    Journal of Materials Research, 1997, 12 : 1942 - 1945
  • [35] Combination of optical methods and atomic force microscopy at characterization of thin film systems
    Ohlídal, I
    Franta, D
    Klapetek, P
    ACTA PHYSICA SLOVACA, 2005, 55 (03) : 271 - 294
  • [36] The Study on the Ultrasonic Nanomachining of Au/Ti Thin Film by Atomic Force Microscopy
    Huang, Jen-Ching
    Chang, Ho
    You, Yong-Chin
    Ling, Hui-Ti
    ADVANCED DEVELOPMENT IN INDUSTRY AND APPLIED MECHANICS, 2014, 627 : 35 - +
  • [37] Influence of atomic force microscopy acquisition parameters on thin film roughness analysis
    Hristu, Radu
    Stanciu, Stefan G.
    Stanciu, George A.
    Capan, Inci
    Guner, Burcu
    Erdogan, Matem
    MICROSCOPY RESEARCH AND TECHNIQUE, 2012, 75 (07) : 921 - 927
  • [38] Scratching on polystyrene thin film without bumps using atomic force microscopy
    Iwata, F
    Matsumoto, T
    Ogawa, R
    Sasaki, A
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1999, 17 (06): : 2452 - 2456
  • [39] Electrochemical method and atomic force microscopy serving the characterization of thin film in bioliquids
    Gavrila, R
    Popescu, B
    Ionescu, D
    Demetrescu, I
    2001 INTERNATIONAL SEMICONDUCTOR CONFERENCE, VOL 1 & 2, PROCEEDINGS, 2001, : 277 - 280
  • [40] Preparation and Atomic Force Microscopy of CTAB stabilized Polythiophene Nanoparticles Thin Film
    Graak, Pinki
    Devi, Ranjna
    Kumar, Dinesh
    Singh, Vishal
    Kumar, Sacheen
    INTERNATIONAL CONFERENCE ON CONDENSED MATTER AND APPLIED PHYSICS (ICC 2015), 2016, 1728