Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry

被引:22
|
作者
Srivannaboon, Sabong [2 ]
Soeharnila [2 ,3 ]
Chirapapaisan, Chareenun [1 ]
Chonpimai, Pratuangsri [2 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Dept Ophthalmol, SiLASIK Ctr, Bangkok 10700, Thailand
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Bangkok 10700, Thailand
[3] Klin Mata Nusantara, Jakarta, Indonesia
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2012年 / 38卷 / 12期
关键词
SURGICALLY INDUCED ASTIGMATISM; INTRAOCULAR-LENS CALCULATION; DUAL SCHEIMPFLUG ANALYZER; ACCURACY; EYES; SURGERY; REPEATABILITY; TOPOGRAPHER; PENTACAM; VIDEOKERATOGRAPHY;
D O I
10.1016/j.jcrs.2012.07.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the corneal astigmatism (magnitude and axis location) derived by total corneal power (TCP), automated keratometry, and simulated keratometry. SETTING: Siriraj Hospital, Mahidol University, Bangkok, Thailand. DESIGN: Prospective comparative study. METHODS: Eyes with previous ocular surgery or abnormalities were excluded. All patients were examined with the ARK 730A autokeratometer and the Galilei analyzer. The steepest and flattest corneal power along with the steepest axis of the TCP, automated keratometry, and simulated keratometry were recorded. Vector analysis (J0 and J45) was calculated. Analysis of variance with Bonferroni correction was performed for multiple comparisons. Outcome measures were the magnitude and axis location of astigmatism. RESULTS: One hundred eyes of 100 cataract patients were randomly selected. There was no statistically significant difference in the mean steepest axis between TCP (93.31 +/- 68.75 [SD]), automated keratometry (94.24 +/- 64.78), and simulated keratometry (92.42 +/- 64.30). However, the mean magnitude of astigmatism measured by TCP (1.23 +/- 0.75) was significantly higher than that measured by automated keratometry (0.93 +/- 0.68) (P = .01) but not than that measured by simulated keratometry (1.08 +/- 0.68) (P = .43); there was no statistically significant difference in J0 or J45. Twenty two (40%) of 54 eyes with more than 1.00 diopter of TCP astigmatism had more than 10 degrees of axis difference from automated keratometry. CONCLUSIONS: The magnitude of TCP astigmatism was higher than that of automated keratometry. The axis location was similar. However, there was more than 10 degrees of axis difference between automated keratometry and TCP in patients with high astigmatism. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2012; 38:2088-2093 (C) 2012 ASCRS and ESCRS
引用
收藏
页码:2088 / 2093
页数:6
相关论文
共 50 条
  • [21] Differences Between Simulated Keratometry and Total Corneal Power in Eyes With Keratoconus and a Formula to Improve IOL Power Calculation Results
    Coutinho, Catarina P.
    Schiano-Lomoriello, Domenico
    Mazzotta, Cosimo
    Ferrise, Marco
    Hoffer, Kenneth J.
    Ribeiro, Filomena J.
    Dias, Joao Mendanha
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (04) : e253 - e259
  • [22] Comparison of total keratometry with corneal power measured by optical low-coherence reflectometry and placido-dual Scheimpflug system
    Kommineni, Usha Bhanu
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Reddy, Jagadesh C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (03) : 1496 - 1503
  • [23] Vecto-keratometry: determination of anterior corneal astigmatism in manual keratometers using power vectors
    Salvador-Roger, Raquel
    Vila-Andres, Rosa
    Mico, Vicente
    Esteve-Taboada, Jose J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (06) : 517 - 524
  • [24] Differences in corneal astigmatism between partial coherence interferometry biometry and automated keratometry and relation to topographic pattern
    Park, Ji-Hye
    Kang, Su Yeon
    Kim, Hyo-Myung
    Song, Jong-Suk
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09): : 1694 - 1698
  • [25] Comparison of keratometry and total corneal power, as measured by an SS-OCT-based optical biometer, for intraocular lens power calculation in Asian eyes
    Savini, Giacomo
    Taroni, Leonardo
    Jeon, Sohee
    Koh, Kyungmin
    Yang, Hyun Seung
    Abulafia, Adi
    Lupardi, Enrico
    Hoffer, Kenneth J.
    Moramarco, Antonio
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11): : 1117 - 1122
  • [26] Anterior Surface-Based Keratometry Compared With Scheimpflug Tomography-Based Total Corneal Astigmatism
    Tonn, Bastian
    Klaproth, Oliver Klaus
    Kohnen, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (01) : 291 - 298
  • [27] Keratometry versus total corneal refractive power: Analysis of measurement repeatability with 5 different devices in normal eyes with low astigmatism
    Fityo, Sylvia
    Buehren, Jens
    Shajari, Mehdi
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 569 - 576
  • [28] COMPARISON OF CORNEAL POWER CALCULATION BY STANDARD KERATOMETRY AND TOTAL KERATOMETRY IN EYES WITH PREVIOUS MYOPIC FS-LASIK (vol 37, pg 848, 2021)
    Lupardi, Enrico
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Schiano-Lomoriello, Domenico
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (02)
  • [29] Prevalence data for total corneal astigmatism in cataract patients
    Bian, Linbo
    Ma, Baikai
    Sun, Zhengze
    Li, Wenlong
    Liu, Yiyun
    Qin, Rui
    Chen, Jiawei
    Ma, Yunke
    Zhao, Lu
    Qi, Hong
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (10) : 3219 - 3227
  • [30] Comparison of corneal surgically induced astigmatism calculations based on keratometry measurements made by 2 biometric devices
    Abulafia, Adi
    Rein, Adi Porat
    Weill, Yishay
    Zadok, David
    Mourits, Maarten P.
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : 1542 - 1547