A biomechanical comparison of four different cementless press-fit stems used in revision surgery for total knee replacements

被引:0
作者
Zdero, Radovan [1 ,2 ]
Saidi, Kevan [3 ]
Mason, Stephanie A. [1 ]
Schemitsch, Emil H. [4 ]
Naudie, Douglas D. R. [5 ]
机构
[1] St Michaels Hosp, Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Sudbury Reg Hosp, Sudbury, ON, Canada
[4] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A1, Canada
[5] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
Biomechanics; press-fit stems; revision surgery; total knee replacement; FINITE-ELEMENT-ANALYSIS; TOTAL HIP IMPLANT; FRACTURE FIXATION; TIBIAL COMPONENT; SYNTHETIC FEMURS; FEMORAL STEMS; IN-VITRO; ARTHROPLASTY; DESIGN; STABILITY;
D O I
10.1177/0954411912453246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.
引用
收藏
页码:848 / 857
页数:10
相关论文
共 46 条
[11]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[12]   The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position [J].
Dubov, A. ;
Kim, S. Y. R. ;
Shah, S. ;
Schemitsch, E. H. ;
Zdero, R. ;
Bougherara, H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H9) :857-865
[13]   Stem fixation in revision total knee arthroplasty - A comparative analysis [J].
Fehring, TK ;
Odum, S ;
Olekson, C ;
Griffin, WL ;
Mason, JB ;
McCoy, TH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :217-224
[14]   A Biomechanical Evaluation of Press-Fit Stem Constructs for Tumor Endoprosthetic Reconstruction of the Distal Femur [J].
Ferguson, Peter C. ;
Zdero, Rad ;
Schemitsch, Emil H. ;
Deheshi, Benjamin M. ;
Bell, Robert S. ;
Wunder, Jay S. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (08) :1373-1379
[15]   The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty [J].
Jazrawi, LM ;
Bai, B ;
Kummer, FJ ;
Hiebert, R ;
Stuchin, SA .
JOURNAL OF ARTHROPLASTY, 2001, 16 (06) :759-767
[16]   Analysis of biomechanical effect of stem-end design in revision TKA using Digital Korean model [J].
Kim, Yoon Hyuk ;
Kwon, Oh Soo ;
Kim, Kyungsoo .
CLINICAL BIOMECHANICS, 2008, 23 (07) :853-858
[17]  
Kirk PG., 1997, REVISION TOTAL KNEE, P137
[18]   A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures [J].
Kuzyk, Paul R. T. ;
Shah, Suraj ;
Zdero, Rad ;
Olsen, Michael ;
Waddell, James P. ;
Schemitsch, Emil H. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (02) :E65-E70
[19]  
Kuzyk Paul R.T., 2009, J of Orthop Trauma
[20]   STRENGTH REDUCTIONS FROM METASTATIC CORTICAL DEFECTS IN LONG BONES [J].
MCBROOM, RJ ;
CHEAL, EJ ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (03) :369-378