A biomechanical comparison of four different cementless press-fit stems used in revision surgery for total knee replacements

被引:0
作者
Zdero, Radovan [1 ,2 ]
Saidi, Kevan [3 ]
Mason, Stephanie A. [1 ]
Schemitsch, Emil H. [4 ]
Naudie, Douglas D. R. [5 ]
机构
[1] St Michaels Hosp, Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Sudbury Reg Hosp, Sudbury, ON, Canada
[4] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A1, Canada
[5] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
Biomechanics; press-fit stems; revision surgery; total knee replacement; FINITE-ELEMENT-ANALYSIS; TOTAL HIP IMPLANT; FRACTURE FIXATION; TIBIAL COMPONENT; SYNTHETIC FEMURS; FEMORAL STEMS; IN-VITRO; ARTHROPLASTY; DESIGN; STABILITY;
D O I
10.1177/0954411912453246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.
引用
收藏
页码:848 / 857
页数:10
相关论文
共 46 条
[1]   THE EFFECT OF A STEM ON THE TIBIAL COMPONENT OF KNEE ARTHROPLASTY - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY OF UNCEMENTED TIBIAL COMPONENTS IN THE FREEMAN-SAMUELSON KNEE ARTHROPLASTY [J].
ALBREKTSSON, BEJ ;
RYD, L ;
CARLSSON, LV ;
FREEMAN, MAR ;
HERBERTS, P ;
REGNER, L ;
SELVIK, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02) :252-258
[2]   The effect of stem design on end-of-stem pain in revision total knee arthroplasty [J].
Barrack, RL ;
Stanley, T ;
Burt, M ;
Hopkins, S .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :119-124
[3]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[4]   STEMMED REVISION ARTHROPLASTY FOR ASEPTIC LOOSENING OF TOTAL KNEE REPLACEMENT [J].
BERTIN, KC ;
FREEMAN, MAR ;
SAMUELSON, KM ;
RATCLIFFE, SS ;
TODD, RC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :242-248
[5]   The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis [J].
Bougherara, H. ;
Zdero, R. ;
Miric, M. ;
Shah, S. ;
Hardisty, M. ;
Zalzal, P. ;
Schemitsch, E. H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H3) :303-314
[6]   A Preliminary Biomechanical Assessment of a Polymer Composite Hip Implant Using an Infrared Thermography Technique Validated by Strain Gage Measurements [J].
Bougherara, Habiba ;
Rahim, Ehsan ;
Shah, Suraj ;
Dubov, Anton ;
Schemitsch, Emil H. ;
Zdero, Rad .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (07)
[7]  
BOURNE RB, 1986, CLIN ORTHOP RELAT R, P95
[8]  
BROOKS PJ, 1984, CLIN ORTHOP RELAT R, P302
[9]   Strain shielding in proximal tibia of stemmed knee prosthesis: Experimental study [J].
Completo, A. ;
Fonseca, F. ;
Simoes, J. A. .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :560-566
[10]   Revision total knee arthroplasty: The influence of femoral stems in load sharing and stability [J].
Completo, A. ;
Simoes, J. A. ;
Fonseca, F. .
KNEE, 2009, 16 (04) :275-279