Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique

被引:246
作者
Katsura, Masaki [1 ]
Matsuda, Izuru [1 ]
Akahane, Masaaki [1 ]
Sato, Jiro [1 ]
Akai, Hiroyuki [1 ]
Yasaka, Koichiro [1 ]
Kunimatsu, Akira [1 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo 1138655, Japan
关键词
Model-based iterative reconstruction; Adaptive statistical iterative reconstruction; Radiation dose reduction; Image noise; Spatial resolution; FILTERED BACK-PROJECTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; EXPOSURE; KERNEL; NOISE;
D O I
10.1007/s00330-012-2452-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 +/- 3.00) than low-dose ASIR (49.24 +/- 9.11, P < 0.01) and reference-dose ASIR images (24.93 +/- 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. aEuro cent Model-based iterative reconstruction (MBIR) creates high-quality low-dose CT images. aEuro cent MBIR significantly improves image noise and artefacts over adaptive statistical iterative techniques. aEuro cent MBIR shows greater potential than ASIR for diagnostically acceptable low-dose CT. aEuro cent The prolonged processing time of MBIR may currently limit its routine use in clinical practice.
引用
收藏
页码:1613 / 1623
页数:11
相关论文
共 26 条
[11]   Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters - Pilot study [J].
Kalra, MK ;
Maher, MM ;
Sahani, DV ;
Blake, MA ;
Hahn, PF ;
Avinash, GB ;
Toth, TL ;
Halpern, E ;
Saini, S .
RADIOLOGY, 2003, 228 (01) :251-256
[12]   A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction [J].
Leipsic, Jonathon ;
Nguyen, Giang ;
Brown, Jaqueline ;
Sin, Don ;
Mayo, John R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :1095-1099
[13]   Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :649-654
[14]   Radiologic and Nuclear Medicine Studies in the United States and Worldwide: Frequency, Radiation Dose, and Comparison with Other Radiation Sources-1950-2007 [J].
Mettler, Fred A., Jr. ;
Bhargavan, Mythreyi ;
Faulkner, Keith ;
Gilley, Debbie B. ;
Gray, Joel E. ;
Ibbott, Geoffrey S. ;
Lipoti, Jill A. ;
Mahesh, Mahadevappa ;
McCrohan, John L. ;
Stabin, Michael G. ;
Thomadsen, Bruce R. ;
Yoshizumi, Terry T. .
RADIOLOGY, 2009, 253 (02) :520-531
[15]   Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique [J].
Prakash, Priyanka ;
Kalra, Mannudeep K. ;
Ackman, Jeanne B. ;
Digumarthy, Subba R. ;
Hsieh, Jiang ;
Do, Synho ;
Shepard, Jo-Anne O. ;
Gilman, Matthew D. .
RADIOLOGY, 2010, 256 (01) :261-269
[16]   Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique [J].
Prakash, Priyanka ;
Kalra, Mannudeep K. ;
Kambadakone, Avinash K. ;
Pien, Homer ;
Hsieh, Jiang ;
Blake, Michael A. ;
Sahani, Dushyant V. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (04) :202-210
[17]   Radiation Dose Reduction With Chest Computed Tomography Using Adaptive Statistical Iterative Reconstruction Technique: Initial Experience [J].
Prakash, Priyanka ;
Kalra, Mannudeep K. ;
Digumarthy, Subba R. ;
Hsieh, Jiang ;
Pien, Homer ;
Singh, Sarabjeet ;
Gilman, Matthew D. ;
Shepard, Jo-Anne O. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) :40-45
[18]   Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients [J].
Sagara, Yoshiko ;
Hara, Amy K. ;
Pavlicek, William ;
Silva, Alvin C. ;
Paden, Robert G. ;
Wu, Qing .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :713-719
[19]   NCRP REPORT NO. 160, IONIZING RADIATION EXPOSURE OF THE POPULATION OF THE UNITED STATES, MEDICAL EXPOSURE-ARE WE DOING LESS WITH MORE, AND IS THERE A ROLE FOR HEALTH PHYSICISTS? [J].
Schauer, D. A. ;
Linton, O. W. .
HEALTH PHYSICS, 2009, 97 (01) :1-5
[20]   National survey of doses from CT in the UK: 2003 [J].
Shrimpton, P. C. ;
Hillier, M. C. ;
Lewis, M. A. ;
Dunn, M. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (948) :968-980