Characteristics of groundwater seepage with cut-off wall in gravel aquifer. I: Field observations

被引:109
作者
Wu, Yong-Xia [1 ]
Shen, Shui-Long [1 ]
Xu, Ye-Shuang [1 ]
Yin, Zhen-Yu [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Civil Engn, State Key Lab Ocean Engn, Shanghai 200240, Peoples R China
[2] LUNAM Univ, EcoleCent Nantes, GeM UMR CNRS, F-6183 Nantes, France
关键词
gravel strata; deep excavation; pumping test; cut-off walls; dewatering; settlement; DEEP FOUNDATION PIT; CENTRAL-ISLAND TECHNIQUE; LAND SUBSIDENCE; PUMPING TESTS; NUMERICAL-SIMULATION; CONFINED AQUIFER; SHANGHAI; BEHAVIOR; CONSTRUCTION; CLAYS;
D O I
10.1139/cgj-2014-0285
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper presents a case history of the leakage behavior during dewatering tests in the gravel strata of an excavation pit of a metro station in Hangzhou, China. The groundwater system at the test site is composed of a phreatic aquifer underlain by an aquitard and a confined aquifer with coarse sand and gravel. The sandy gravel stratum has very high hydraulic conductivity. The maximum depth of the excavation is 24 m below the ground surface, which reaches the middle of the aquitard strata, where the thickness of the clayey soil is insufficient to maintain the safety of the base of the excavation. To understand the hydrological characteristics of gravel strata, single- and double-well pumping tests were conducted, where a cut-off wall was installed 43 m deep with its base penetrating 2 to 3 m into the aquifer. Test results show that this partial cut-off of the aquifer cannot effectively protect the base of the excavation from the upward seepage force of the groundwater during excavation. Therefore, a new cut-off wall (second phase) was constructed to a depth of 54 m to cut off the confined aquifer. A second pumping test was conducted after the construction of the second phase cut-off wall, and test results show that this full cut-off combined with dewatering can control groundwater effectively during excavation. This finding indicates that when a deep excavation is conducted in a confined aquifer with high hydraulic conductivity, determination of the depth of the retaining wall should be based on three factors: the stability of the base, the upward seepage stability, and settlement control.
引用
收藏
页码:1526 / 1538
页数:13
相关论文
共 52 条
[1]  
[Anonymous], 2002, 500072002 GBT
[2]  
[Anonymous], 2003, Design and Execution of Dewatering Theory of Seepage in Deep Excavation
[3]  
[Anonymous], 2011, ASTM International
[4]   Land subsidence due to groundwater drawdown in Shanghai [J].
Chai, JC ;
Shen, SL ;
Zhu, HH ;
Zhang, XL .
GEOTECHNIQUE, 2004, 54 (02) :143-147
[5]   Pumping test in a confined aquifer under tidal influence [J].
Chapuis, RP ;
Bélanger, C ;
Chenaf, D .
GROUND WATER, 2006, 44 (02) :300-305
[6]   Effects of monitoring and pumping well pipe capacities during pumping tests in confined aquifers [J].
Chapuis, RP ;
Chenaf, D .
CANADIAN GEOTECHNICAL JOURNAL, 2003, 40 (06) :1093-1103
[7]   SIMILARITY OF INTERNAL STABILITY-CRITERIA FOR GRANULAR SOILS [J].
CHAPUIS, RP .
CANADIAN GEOTECHNICAL JOURNAL, 1992, 29 (04) :711-713
[8]  
Cooper HH., 1946, EOS T AM GEOPHYS UN, V27, P526, DOI [10.1029/TR027i004p00526, DOI 10.1029/TR027I004P00526]
[9]   Full-Scale Instrumented Testing and Three-Dimensional Modeling of Airfield Matting Systems [J].
Doyle, Jesse D. ;
Howard, Isaac L. ;
Gartrell, Chad A. ;
Anderton, Gary L. ;
Newman, J. Kent ;
Berney, Ernest S. .
INTERNATIONAL JOURNAL OF GEOMECHANICS, 2014, 14 (02) :161-170
[10]  
Driscoll F., 1986, GROUNDWATER WELLS