Ionic liquids as modifiers for glass and SU-8 electrochemical microfluidic chips

被引:9
作者
Alvarez-Martos, Isabel [1 ]
Garcia Alonso, Francisco Javier [2 ]
Anillo, Adela [2 ]
Arias-Abrodo, Pilar [1 ]
Dolores Gutierrez-Alvarez, Maria [1 ]
Costa-Garcia, Agustin [1 ]
Teresa Fernandez-Abedul, Maria [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
[2] Univ Oviedo, Dept Quim Organ & Inorgan, Asturias, Spain
关键词
Microchip electrophoresis; SU-8; microchips; Glass microchips; End-channel amperometric detection; Ionic liquids; Catecholamines; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; MICROCHIP ELECTROPHORESIS; CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; SEPARATION; PERFORMANCE; POLY(DIMETHYLSILOXANE); CATECHOLAMINES; ADDITIVES; POLY(METHYLMETHACRYLATE);
D O I
10.1016/j.snb.2013.07.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ionic liquids have been attracting attention as background additives to improve separations in the last years. This work reports about the use of four ionic liquids (ILs): 1-butyl-4-methylpyridinum tetrafluoroborate (BMPyBF4), 1-buty1-3-methylimidazolium tetrafluoroborate (BMIMBF4), 1-buty1-3methylimidazolium hydrogen sulfate (BMIMHSO4) and 1-ethy1-3-methylimidazolium methyl sulfate (EMIMMeSO4) as dynamic modifiers in glass and SU-8 microchip electrophoresis (ME). The influence of varying pH values and ILs concentration on the detection system was investigated. Moreover, ionic liquids with different cations and counterions were evaluated as background additives choosing two catecholamines (dopamine, DA and epinephrine, E) as model analytes. Dynamic modification with ILs proved to be necessary to obtain enhanced mixture separation in both 30 mm glass and SU-8 MEs. Good precision in terms of migration times and resolution was obtained for both kinds of MEs when ILs were employed. In addition, baseline resolution with good reproducibility over time (RSD values of 0.5% and 0.8% for migration times in one experiment and three days, respectively) was achieved in glass MEs with 60 mm effective separation length. (C) 2013 Published by Elsevier B.V.
引用
收藏
页码:837 / 846
页数:10
相关论文
共 64 条
[1]   Poly (acrylic acid) microchannel modification for the enhanced resolution of catecholamines microchip electrophoresis with electrochemical detection [J].
Alvarez-Martos, Isabel ;
Teresa Fernandez-Abedul, M. ;
Anillo, Adela ;
Fierro, Jose Luis G. ;
Garcia Alonso, Francisco Javier ;
Costa-Garcia, Agustin .
ANALYTICA CHIMICA ACTA, 2012, 724 :136-143
[2]   Latest Developments in Micro Total Analysis Systems [J].
Arora, Arun ;
Simone, Giuseppina ;
Salieb-Beugelaar, Georgette B. ;
Kim, Jung Tae ;
Manz, Andreas .
ANALYTICAL CHEMISTRY, 2010, 82 (12) :4830-4847
[3]   The viscosity of pure liquids. II. Polymerised ionic melts. [J].
Barrer, RM .
TRANSACTIONS OF THE FARADAY SOCIETY, 1943, 39 :0059-0066
[4]   Ionic liquids in separation techniques [J].
Berthod, A. ;
Ruiz-Angel, Mt ;
Carda-Broch, S. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :6-18
[5]   Capillary zone electrophoresis on chemically bonded imidazolium based salts [J].
Borissova, Maria ;
Vaher, Merike ;
Koel, Mihkel ;
Kaljurand, Mihkel .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) :320-325
[6]   Integration of serpentine channels for microchip electrophoresis with a palladium decoupler and electrochemical detection [J].
Bowen, Amanda L. ;
Martin, R. Scott .
ELECTROPHORESIS, 2009, 30 (19) :3347-3354
[7]   Capillary and microchip electrophoresis: Challenging the common conceptions [J].
Breadmore, Michael C. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1221 :42-55
[8]   Development of a micro-total analysis system (μ-TAS) for the determination of catecholamines [J].
Cakal, Cafer ;
Ferrance, Jerome P. ;
Landers, James P. ;
Caglar, Perihan .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (05) :1909-1917
[9]   Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ELECTROPHORESIS, 2005, 26 (16) :3160-3168
[10]   Fabrication of SU-8 based microchip electrophoresis with integrated electrochemical detection for neurotransmitters [J].
Castano-Alvarez, Mario ;
Teresa Fernandez-Abedul, M. ;
Costa-Garcia, Agustin ;
Agirregabiria, Maria ;
Fernandez, Luis J. ;
Miguel Ruano-Lopez, Jesus ;
Barredo-Presa, Borja .
TALANTA, 2009, 80 (01) :24-30