NOISE-ADAPTIVE ATTENUATION COEFFICIENT ESTIMATION IN SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY DATA

被引:5
作者
Ghafaryasl, Babak [1 ,2 ]
Vermeer, Koenraad A. [1 ]
de Boer, Johannes F. [3 ]
van Velthoven, Mirjam E. J. [4 ]
vanVliet, Lucas J. [2 ]
机构
[1] Rotterdam Ophthalm Inst, Rotterdam, Netherlands
[2] Delft Univ Technol, Quantitat Imaging Grp, Delft, Netherlands
[3] Vrije Univ Amsterdam, Dept Phys & Astron, Amsterdam, Netherlands
[4] Rotterdam Eye Hosp, Med Retina Serv, Rotterdam, Netherlands
来源
2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI) | 2016年
关键词
SD-OCT; roll-off; retina; choroid; sclera; RNFL;
D O I
10.1109/ISBI.2016.7493364
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The attenuation coefficient (AC) is a tissue property that can be estimated from optical coherence tomography (OCT) data. We observed that excessive noise below the retina might cause both an underestimation and a significant variation of the estimated AC values by a state-of-the-art algorithm. Two methods were proposed to reduce these effects: I) by removing the average noise signal from the OCT data; II) by excluding the detected noise region below the retina. The methods were applied to four circular peripapillary retinal scans of a healthy subject. We evaluated all methods quantitatively using metrics for the inter-and intra-Alines variation of the estimated ACs. Both methods resulted in higher ACs thereby reducing the bias. However, only method II succeeded in reducing the amount of variation by both metrics; method I made things worse. In conclusion, method II yields a more robust and more precise estimate of the AC, in particular for the choroid and sclera, compared to the baseline method.
引用
收藏
页码:706 / 709
页数:4
相关论文
共 4 条
  • [1] Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography
    Faber, DJ
    van der Meer, FJ
    Aalders, MCG
    van Leeuwen, TG
    [J]. OPTICS EXPRESS, 2004, 12 (19): : 4353 - 4365
  • [2] Depth-resolved model-based reconstruction of attenuation coefficients in optical coherence tomography
    Vermeer, K. A.
    Mo, J.
    Weda, J. J. A.
    Lemij, H. G.
    de Boer, J. F.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 322 - 337
  • [3] RPE-Normalized RNFL Attenuation Coefficient Maps Derived from Volumetric OCT Imaging for Glaucoma Assessment
    Vermeer, Koenraad A.
    van der Schoot, Josine
    Lemij, Hans G.
    de Boer, Johannes F.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (10) : 6102 - 6108
  • [4] High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength
    Yun, SH
    Tearney, GJ
    Bouma, BE
    Park, BH
    de Boer, JF
    [J]. OPTICS EXPRESS, 2003, 11 (26): : 3598 - 3604