Feasibility study of a time-resolving x-ray tomographic system

被引:25
作者
Mudde, R. F. [1 ]
Alles, J. [1 ]
van der Hagen, T. H. J. J. [2 ]
机构
[1] Delft Univ Technol, Kramers Lab Fys Technol, NL-2628 BW Delft, Netherlands
[2] Delft Univ Technol, Reactor Phys Dept, NL-2629 JB Delft, Netherlands
关键词
x-ray tomography; time-resolved; SART; regularization; fluidized bed;
D O I
10.1088/0957-0233/19/8/085501
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper discusses the possibilities for developing a tomographic scanner for studying the phase distribution of fluidized beds. The system is based on a medical x-ray source equipped with 30 CdWO4 detectors. We mimic a five-source system via simulation and in experiments of voids in a 23 fluidized bed filled with polystyrene particles. Both static voids and moving ones are studied. The reconstruction uses the simultaneous algebraic reconstruction technique with regularization. We find that it is possible to reconstruct objects with a spatial resolution of about 5 mm at a frame rate of 200 Hz. It is concluded that noise levels should be kept below 2%.
引用
收藏
页数:14
相关论文
共 24 条
[1]   Bayesian image reconstruction for emission tomography based on median root prior [J].
Sakari Alenius ;
Ulla Ruotsalainen .
European Journal of Nuclear Medicine, 1997, 24 (3) :258-265
[2]   Beam hardening: Analytical considerations of the effective attenuation coefficient of x-ray tomography [J].
Alles, J. ;
Mudde, R. F. .
MEDICAL PHYSICS, 2007, 34 (07) :2882-2889
[3]   SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM [J].
ANDERSEN, AH ;
KAK, AC .
ULTRASONIC IMAGING, 1984, 6 (01) :81-94
[4]   Process tomography - the state of the art [J].
Beck, MS ;
Dyakowski, T ;
Williams, RA .
TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 1998, 20 (04) :163-177
[5]   Evaluation of a limited angle scanned electron beam x-ray CT approach for two-phase pipe flows [J].
Bieberle, M. ;
Hampel, U. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (08) :2057-2065
[6]   Ultrafast limited-angle-type x-ray tomography [J].
Bieberle, M. ;
Fischer, F. ;
Schleicher, E. ;
Hampel, U. ;
Koch, D. ;
Aktay, K. S. D. C. ;
Menz, H.-J. ;
Mayer, H.-G. .
APPLIED PHYSICS LETTERS, 2007, 91 (12)
[7]  
BISSESSUR Y, 2005, P 4 WORLD C IND P TO, P552
[8]   PRINCIPLES OF COMPUTER-ASSISTED TOMOGRAPHY (CAT) IN RADIOGRAPHIC AND RADIOISOTOPIC IMAGING [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :689-732
[9]   Opaque multiphase reactors: Experimentation, modeling and troubleshooting [J].
Dudukovic, MP .
OIL & GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES, 2000, 55 (02) :135-158
[10]   ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&