Assessment of the actual hygrothermal performance of glass mineral wool insulation applied 25 years ago in masonry cavity walls

被引:24
作者
Stazi, F. [1 ]
Tittarelli, F. [2 ]
Politi, G. [1 ]
Di Perna, C. [3 ]
Munafo, P. [1 ]
机构
[1] Univ Politecn Marche, DICEA, I-60131 Ancona, Italy
[2] Univ Politecn Marche, Dipartimento Sci & Ingn Mat Ambiente & Urbanist, I-60131 Ancona, Italy
[3] Univ Politecn Marche, Dipartimento Energet, I-60131 Ancona, Italy
关键词
Durability; Thermal insulation material; Glass-wool; Experimental study; Laboratory measurements; Long term assessment; Retrofit interventions; On-site comfort monitoring; Hygrothermal performance; MOISTURE; SYSTEM;
D O I
10.1016/j.enbuild.2013.09.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study was carried out on buildings constructed in the 1980s adopting vertical envelopes with a glass wool insulation layer in the cavity. The aims of this study are to evaluate the insulation conservation state after 25 years, to assess the actual indoor thermal comfort and to compare different retrofit interventions. The research included the following phases: laboratory tests on insulation samples to quantify any changes of morphological, chemical, physical and thermal proprieties of the material; detailed on-site monitoring in order to analyze the thermal comfort conditions; dynamic thermal simulations to assess the impact of different retrofit scenarios to satisfy the limits imposed by the current energy saving standard. The results show that the glass fibers and the binder were affected by a degradation process thus increasing both water absorption and thermal conductivity; thermal comfort and consumptions were not influenced by the insulation aging; the most effective retrofit is the introduction of an external insulation layer. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:292 / 304
页数:13
相关论文
共 11 条
[1]   The variation of thermal conductivity of fibrous insulation materials under different levels of moisture content [J].
Abdou, A. ;
Budaiwi, I. .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 43 :533-544
[2]   Hydric, morphological and thermo-physical characterization of glass wools: From macroscopic to microscopic approach [J].
Achchaq, Fouzia ;
Djellab, Karim ;
Beji, Hassen .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (10) :3214-3219
[3]   Properties of thermal insulation materials during extreme environment changes [J].
Bjork, Folke ;
Enochsson, Tomas .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (06) :2189-2195
[4]   Experimental study on the performance of insulation materials in Mediterranean construction [J].
Cabeza, L. F. ;
Castell, A. ;
Medrano, M. ;
Martorell, I. ;
Perez, G. ;
Fernandez, I. .
ENERGY AND BUILDINGS, 2010, 42 (05) :630-636
[5]   ISOTHERMS OF WATER VAPOR SORPTION BY LIGHT INORGANIC AND POLYMER HEAT-INSULATING MATERIALS [J].
Gnip, I. Ya. ;
Veyalis, S. A. ;
Kershulis, V. I. .
JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2006, 79 (01) :40-47
[6]   Effect of hydrophilic admixtures on moisture and heat transport and storage parameters of mineral wool [J].
Jiricková, M ;
Cerny, R .
CONSTRUCTION AND BUILDING MATERIALS, 2006, 20 (06) :425-434
[7]   Experimental assessment of hygrothermal performance of an interior thermal insulation system using a laboratory technique simulating on-site conditions [J].
Pavlik, Zbysek ;
Cerny, Robert .
ENERGY AND BUILDINGS, 2008, 40 (05) :673-678
[8]   Assessment of the performance of organic and mineral-based insulation products used in exterior walls and attics in dwellings [J].
Rasmussen, Torben Valdbjorn ;
Nicolajsen, Asta .
BUILDING AND ENVIRONMENT, 2007, 42 (02) :829-839
[9]   Durability of 20-year-old external insulation and assessment of various types of retrofitting to meet new energy regulations [J].
Stazi, F. ;
Di Perna, C. ;
Munafo, P. .
ENERGY AND BUILDINGS, 2009, 41 (07) :721-731
[10]   Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier [J].
Toman, Jan ;
Vimmrova, Alena ;
Cerny, Robert .
ENERGY AND BUILDINGS, 2009, 41 (01) :51-55