Transient Reference Values for Impulse Oscillometry for Children Aged 3-18 Years

被引:91
作者
Nowowiejska, Boena [2 ]
Tomalak, Waldemar [1 ]
Radlinski, Jakub [1 ]
Siergiejko, Grzegorz [2 ]
Latawiec, Wojciech [1 ]
Kaczmarski, Maciej [2 ]
机构
[1] Natl Res Inst TB & Lung Dis, Dept Physiopathol Resp Syst, Rabka Branch, PL-34700 Rabka, Poland
[2] Med Acad, Dept Pediat 3, Bialystok, Poland
关键词
children; adolescents; impulse oscillometry; reference values;
D O I
10.1002/ppul.20926
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Impulse oscillometry (IOS) is a technique of assessing mechanical properties of respiratory system by means of measuring resistances and reactances in a number of frequencies during tidal breathing. It is especially useful in preschool children, however has also been validated in older children and adults. The aim of the present study was to construct equations describing normal values of oscillatory parameters in pediatric population of healthy polish children. Six hundred twenty-six healthy children aged 3.1-18.9 years (278 boys and 348 girls) completed the study Analysis revealed that body height was the best predictor and resistances are best described with exponential model while reactances with linear one, with correlation coefficient r reaching the value of 0.9. Oscillometric resistances decrease with height, while reactances increase. Reference values for children and adolescents will allow not only the interpretation of the measurement, but also will make possible to study changes of oscillometric indices during growth. Pediatr Pulmonol. 2008;43: 1193-1197. (c) 2008 Wiley-Liss, Inc.
引用
收藏
页码:1193 / 1197
页数:5
相关论文
共 16 条
[1]  
Arets Hubertus G M, 2004, Paediatr Respir Rev, V5, P77, DOI 10.1016/j.prrv.2003.09.004
[2]   An official American Thoracic Society/European Respiratory Society statement: Pulmonary function testing in preschool children [J].
Beydon, Nicole ;
Davis, Stephanie D. ;
Lombardi, Enrico ;
Allen, Julian L. ;
Arets, Hubertus G. M. ;
Aurora, Paul ;
Bisgaard, Hans ;
Davis, G. Michael ;
Ducharme, Francine M. ;
Eigen, Howard ;
Gappa, Monika ;
Gaultier, Claude ;
Gustafsson, Per M. ;
Hall, Graham L. ;
Hantos, Zoltan ;
Healy, Michael J. R. ;
Jones, Marcus H. ;
Klug, Bent ;
Carlsen, Karin C. Lodrup ;
McKenzie, Sheila A. ;
Marchal, Francois ;
Mayer, Oscar H. ;
Merkus, Peter J. F. M. ;
Morris, Mohy G. ;
Oostveen, Ellie ;
Pillow, J. Jane ;
Seddon, Paul C. ;
Silverman, Michael ;
Sly, Peter D. ;
Stocks, Janet ;
Tepper, Robert S. ;
Vilozni, Daphna ;
Wilson, Nicola M. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2007, 175 (12) :1304-1345
[3]   Measuring bronchodilation in COPD clinical trials [J].
Borrill, ZL ;
Houghton, CM ;
Woodcock, AA ;
Vestbo, J ;
Singh, D .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2005, 59 (04) :379-384
[4]   Impulse oscillometry - Reference values in children 100 to 150 cm in height and 3 to 10 years of age [J].
Frei, J ;
Jutla, J ;
Kramer, G ;
Hatzakis, GE ;
Ducharme, FM ;
Davis, GM .
CHEST, 2005, 128 (03) :1266-1273
[5]   Respiratory impedance in children with cystic fibrosis using forced oscillations in clinic [J].
Gangell, C. L. ;
Horak, F., Jr. ;
Patterson, H. J. ;
Sly, P. D. ;
Stick, S. M. ;
Hall, G. L. .
EUROPEAN RESPIRATORY JOURNAL, 2007, 30 (05) :892-897
[6]   A comparison of plethysmography, spirometry and oscillometry for assessing the pulmonary effects of inhaled ipratropium bromide in healthy subjects and patients with asthma [J].
Houghton, CM ;
Woodcock, AA ;
Singh, D .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2005, 59 (02) :152-159
[7]  
Klug B, 1998, PEDIATR PULM, V25, P322, DOI 10.1002/(SICI)1099-0496(199805)25:5<322::AID-PPUL6>3.0.CO
[8]  
2-K
[9]  
Klug B, 1996, PEDIATR PULM, V21, P290
[10]   Determinants of respiratory system input impedance and bronchodilator response in healthy Finnish preschool children [J].
Malmberg, LP ;
Pelkonen, A ;
Poussa, T ;
Pohjanpalo, A ;
Haahtela, T ;
Turpeinen, M .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (01) :64-71