Three-Dimensional Printing PEEK Implant: A Novel Choice for the Reconstruction of Chest Wall Defect

被引:56
作者
Wang, Lei [1 ]
Huang, Lijun [1 ]
Li, Xiaofei [1 ]
Zhong, Daixing [1 ]
Li, Dichen [2 ]
Cao, Tiesheng [3 ]
Yang, Sanhu [1 ]
Yan, Xiaolong [1 ]
Zhao, Jinbo [1 ]
He, Jiankang [2 ]
Cao, Yi [2 ]
Wang, Ling [2 ]
机构
[1] Fourth Mil Med Univ, Tangdu Hosp, Dept Thorac Surg, 569 Xinsi Rd, Xian 710038, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian, Shaanxi, Peoples R China
[3] Fourth Mil Med Univ, Tangdu Hosp, Dept Ultrasound Diagnost, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
TITANIUM RIBS; FOLLOW-UP; RESECTION; PULMONARY; FUSION;
D O I
10.1016/j.athoracsur.2018.09.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study is to use 3-dimensional printing (3DP) polyetheretherketone (PEEK) implants for skeletal reconstructions after wide excision of chest wall. 3DP PEEK implants were expected to provide a better physiological simulation than traditional ones because of a closer elastic modulus to cortical bone and similar biomechanical properties. Methods. Eighteen patients (mean age 44.5 years), comprising 6 males and 12 females, underwent adequate radical wide excision for tumors and chest wall reconstruction using 3DP PEEK implants. Surgical data, which include patient demographic characteristics, implant preparation parameters, and preoperative and postoperative pulmonary function test results, were collected and analyzed. Results. Ten patients with rib tumors and 8 patients with sternum tumors were selected for the study. The mean chest wall defect size was 173.6 +/- 151.5 cm(2) (range, 55 to 625 cm(2)). The mean weight of a single 3DP PEEK rib and sternum was 28 g and 104 g, respectively. The flexural and tensile strength of PEEK implants were 141 +/- 7 MPa and 89 +/- 3 MPa, respectively. Preoperative and postoperative pulmonary function tests revealed that mean forced vital capacity was from 2.79 +/- 0.68 L to 2.40 +/- 0.70 L with a reduction of 14.0% (p < 0.001). No side effects were observed 6 to 12 months after the operation. Conclusions. These findings suggest that 3DP PEEK implant is a safe and effective alternative in the reconstruction of chest wall defects. The pulmonary function of the patient may be preserved effectively after surgery. (C) 2019 by The Society of Thoracic Surgeons
引用
收藏
页码:921 / 928
页数:8
相关论文
共 24 条
[1]   Dynamic 3D printed titanium copy prosthesis: a novel design for large chest wall resection and reconstruction [J].
Aragon, Javier ;
Perez Mendez, Itzell .
JOURNAL OF THORACIC DISEASE, 2016, 8 (06) :E385-E389
[2]   Tridimensional titanium-printed custom-made prosthesis for sternocostal reconstruction [J].
Aranda, Jose L. ;
Jimenez, Marcelo F. ;
Rodriguez, Maria ;
Varela, Gonzalo .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 48 (04) :E92-E94
[3]  
Brantigan John W, 2004, Spine J, V4, P681, DOI 10.1016/j.spinee.2004.05.253
[4]   Reconstruction of the thoracic wall-long-term follow-up including pulmonary function tests [J].
Daigeler, Adrien ;
Druecke, Daniel ;
Hakimi, Mitra ;
Duchna, Hans-Werner ;
Goertz, Ole ;
Homann, Heinz-Herbert ;
Lehnhardt, Marcus ;
Steinau, Hans-Ulrich .
LANGENBECKS ARCHIVES OF SURGERY, 2009, 394 (04) :705-715
[5]   Early and long-tern results of prosthetic chest wall reconstruction [J].
Deschamps, C ;
Tirnaksiz, BM ;
Darbandi, R ;
Trastek, VF ;
Allen, MS ;
Miller, DL ;
Arnold, PG ;
Pairolero, PC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (03) :588-592
[6]   Rigid and flexible spinal stabilization devices: A biomechanical comparison [J].
Galbusera, Fabio ;
Bellini, Chiara Maria ;
Anasetti, Federica ;
Ciavarro, Cristina ;
Lovi, Alessio ;
Brayda-Bruno, Marco .
MEDICAL ENGINEERING & PHYSICS, 2011, 33 (04) :490-496
[7]   Custom design and biomechanical analysis of 3D-printed PEEK rib prostheses [J].
Kang, Jianfeng ;
Wang, Ling ;
Yang, Chuncheng ;
Wang, Lei ;
Yi, Cao ;
He, Jiankang ;
Li, Dichen .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2018, 17 (04) :1083-1092
[8]   Polyetheretherketone (PEEK) cages in cervical applications: a systematic review [J].
Kersten, Roel Frederik Mark Raymond ;
van Gaalen, Steven M. ;
de Gast, Arthur ;
Oner, F. Cumhur .
SPINE JOURNAL, 2015, 15 (06) :1446-1460
[9]   PEEK biomaterials in trauma, orthopedic, and spinal implants [J].
Kurtz, Steven M. ;
Devine, John N. .
BIOMATERIALS, 2007, 28 (32) :4845-4869
[10]   Chest wall tumors and prosthetic reconstruction: A comparative analysis on functional outcome [J].
Leuzzi, Giovanni ;
Nachira, Dania ;
Cesario, Alfredo ;
Novellis, Pierluigi ;
Ciavarella, Leonardo Petracca ;
Lococo, Filippo ;
Facciolo, Francesco ;
Granone, Pierluigi ;
Margaritora, Stefano .
THORACIC CANCER, 2015, 6 (03) :247-254