Evaluation and Design Tools for the Reliability of Wind Power Converter System

被引:29
作者
Ma, Ke [1 ]
Zhou, Dao [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
关键词
Lifetime; Power Electronics; Reliability; Tools; Wind Power; ELECTRONICS;
D O I
10.6113/JPE.2015.15.5.1149
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a key part in the wind turbine system, the power electronic converter is proven to have high failure rates. At the same time, the failure of the wind power converter is becoming more unacceptable because of the quick growth in capacity, remote locations to reach, and strong impact to the power grid. As a result, the correct assessment of reliable performance for power electronics is a crucial and emerging need; the assessment is essential for design improvement, as well as for the extension of converter lifetime and reduction of energy cost. Unfortunately, there still exists a lack of suitable physic-of-failure based evaluation tools for a reliability assessment in power electronics. In this paper, an advanced tool structure which can acquire various reliability metrics of wind power converter is proposed. The tool is based on failure mechanisms in critical components of the system and mission profiles in wind turbines. Potential methodologies, challenges, and technology trends involved in this tool structure are also discussed. Finally, a simplified version of the tool is demonstrated on a wind power converter based on Double Fed Induction Generator system. With the proposed tool structure, more detailed information of reliability performances in a wind power converter can be obtained before the converter can actually fail in the field and many potential research topics can also be initiated.
引用
收藏
页码:1149 / 1157
页数:9
相关论文
共 27 条
[21]   Five years of operating experience at a large, utility-scale photovoltaic generating plant [J].
Moore, L. M. ;
Post, H. N. .
PROGRESS IN PHOTOVOLTAICS, 2008, 16 (03) :249-259
[22]   Determination of fragments of multiaxial service loading strongly influencing the fatigue of machine components [J].
Nieslony, Adam .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2009, 23 (08) :2712-2721
[23]  
Scheuermann Uwe, 2013, International Conference and Exhibition for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management. Proceedings, P810
[24]  
Wintrich A., 2011, SEMIKRON APPL MAN
[25]  
Wolfgang E., 2005, Proc. World Electron. Packag. Syst. Integr, P246
[26]   An Industry-Based Survey of Reliability in Power Electronic Converters [J].
Yang, Shaoyong ;
Bryant, Angus ;
Mawby, Philip ;
Xiang, Dawei ;
Ran, Li ;
Tavner, Peter .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (03) :1441-1451
[27]   Thermal Cycling Overview of Multi-Megawatt Two-Level Wind Power Converter at Full Grid Code Operation [J].
Zhou, Dao ;
Blaabjerg, Frede ;
Lau, Mogens ;
Tonnes, Michael .
IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2013, 2 (04) :173-182