An Energy Tank-Based Interactive Control Architecture for Autonomous and Teleoperated Robotic Surgery

被引:166
作者
Ferraguti, Federica [1 ]
Preda, Nicola [2 ]
Manurung, Auralius [3 ]
Bonfe, Marcello [2 ]
Lambercy, Olivier [3 ]
Gassert, Roger [3 ]
Muradore, Riccardo [4 ]
Fiorini, Paolo [4 ]
Secchi, Cristian [1 ]
机构
[1] Univ Modena & Reggio Emilia, Dept Sci & Methods Engn, I-41100 Modena, Italy
[2] Univ Ferrara, Dept Engn, I-44121 Ferrara, Italy
[3] ETH, Rehabil Engn Lab, CH-8092 Zurich, Switzerland
[4] Univ Verona, Dept Comp Sci, I-37129 Verona, Italy
关键词
Energy tanks; interactive control; medical robots and systems; telerobotics; BILATERAL TELEOPERATION;
D O I
10.1109/TRO.2015.2455791
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Introducing some form of autonomy in robotic surgery is being considered by the medical community to better exploit the potential of robots in the operating room. However, significant technological steps have to occur before even the smallest autonomous task is ready to be presented to the regulatory authorities. In this paper, we address the initial steps of this process, in particular the development of control concepts satisfying the basic safety requirements of robotic surgery, i.e., providing the robot with the necessary dexterity and a stable and smooth behavior of the surgical tool. Two specific situations are considered: the automatic adaptation to changing tissue stiffness and the transition from autonomous to teleoperated mode. These situations replicate real-life cases when the surgeon adapts the stiffness of her/his arm to penetrate tissues of different consistency and when, due to an unexpected event, the surgeon has to take over the control of the surgical robot. To address the first case, we propose a passivity-based interactive control architecture that allows us to implement stable time-varying interactive behaviors. For the second case, we present a two-layered bilateral control architecture that ensures a stable behavior during the transition between autonomy and teleoperation and, after the switch, limits the effect of initial mismatch between master and slave poses. The proposed solutions are validated in the realistic surgical scenario developed within the EU-funded I-SUR project, using a surgical robot prototype specifically designed for the autonomous execution of surgical tasks like the insertion of needles into the human body.
引用
收藏
页码:1073 / 1088
页数:16
相关论文
共 42 条
[1]  
Anderson RJ, 1996, IEEE INT CONF ROBOT, P2025, DOI 10.1109/ROBOT.1996.506169
[2]  
[Anonymous], 2010, Investors in People, Managerial Capabilities and Performance, a study conducted by the Center for Business Performance Cranfield School of Management
[3]   Position Drift Compensation in Time Domain Passivity based Teleoperation [J].
Artigas, Jordi ;
Ryu, Jee-Hwan ;
Preusche, Carsten .
IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, :4250-4256
[4]  
Baier H., 1997, IEEE/ASME International Conference on Advanced Intelligent Mechatronics '97. Final Program and Abstracts (Cat. No.97TH8298), DOI 10.1109/AIM.1997.652909
[5]  
Barbe L., 2006, P IEEE INT C BIOM RO, P341, DOI DOI 10.1109/TOH.2011.49
[6]  
Bonfê M, 2012, P IEEE RAS-EMBS INT, P56, DOI 10.1109/BioRob.2012.6290700
[7]  
Buchli J., 2010, ROB SCI SYST C ZAR S
[8]  
Feio J., 2009, P 7 WORKSH ADV CONTR
[9]   Passive position error correction in Internet-based teleoperation [J].
Fernandez Villaverde, Alejandro ;
Barreiro, Antonio ;
Raimundez, Cesare .
AUTOMATICA, 2010, 46 (11) :1884-1890
[10]  
Ferraguti F., 2013, IEEE INT C ROB AUT K