Sensitive voltammetric determination of paracetamol by poly (4-vinylpyridine)/multiwalled carbon nanotubes modified glassy carbon electrode

被引:86
作者
Ghadimi, Hanieh [1 ]
Tehrani, Ramin M. A. [1 ]
Ali, Abdussalam Salhin Mohamed [1 ]
Mohamed, Norita [1 ]
Ab Ghani, Sulaiman [1 ]
机构
[1] Univ Sains Malaysia, George Town 11800, Malaysia
关键词
Paracetamol; Multiwalled carbon nanotubes; Poly (4-vinylpyridine); Voltammetric determination; ELECTROCHEMICAL DETERMINATION; ASCORBIC-ACID; PASTE ELECTRODE; ACETAMINOPHEN; SENSOR; GLUCOSE; DISPERSION; SUPERCAPACITOR; NANOPARTICLES; OXIDATION;
D O I
10.1016/j.aca.2012.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel glassy carbon electrode (GCE) modified with a composite film of poly (4-vinylpyridine) (P4VP) and multiwalled carbon nanotubes (P4VP/MWCNT GCE) was used for the voltammetric determination of paracetamol (PCT). This novel electrode displayed a combined effect of P4VP and MWCNT on the electro-oxidation of PCT in a solution of phosphate buffer at pH 7. Hence, conducting properties of P4VP along with the remarkable physical properties of MWCNTs might have combined effects in enhancing the kinetics of PCT oxidation. The P4VP/MWCNT GCE has also demonstrated excellent electrochemical activity toward PCT oxidation compared to that with bare GCE and MWCNT GCE. The anodic peak currents of PCT on the P4VP/MWCNT GCE were about 300 fold higher than that of the non-modified electrodes. By applying differential pulse voltammetry technique under optimized experimental conditions, a good linear ratio of oxidation peak currents and concentrations of PCT over the range of 0.02-450 mu M with a limit of detection of 1.69 nM were achieved. This novel electrode was stable for more than 60 days and reproducible responses were obtained at 99% of the initial current of PCT without any influence of physiologically common interferences such as ascorbic acid and uric acid. The application of this electrode to determine PCT in tablets and urine samples was proposed. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 43 条
[1]   Development of prototype wireless transmission measurement for glucose in subcutaneous and brain striatum [J].
Ahmad, Farook ;
Chow, Fook Cheong ;
Ho, Yah Wen ;
Chin, Yew Siang ;
Christenson, Andreas ;
Bainbridge, Martina ;
Yousof, Ahmad Pauzi Md ;
Ab Ghani, Sulaiman .
ELECTROANALYSIS, 2008, 20 (09) :1008-1015
[2]   A non-aqueous electrolyte-based asymmetric supercapacitor with polymer and metal oxide/multiwalled carbon nanotube electrodes [J].
Amitha, F. Estaline ;
Reddy, A. Leela Mohana ;
Ramaprabhu, S. .
JOURNAL OF NANOPARTICLE RESEARCH, 2009, 11 (03) :725-729
[3]  
[Anonymous], 2010, ELECTROCHIM ACTA
[4]  
Atta NF, 2011, INT J ELECTROCHEM SC, V6, P5082
[5]   Quality control of the paracetamol drug by chemometrics and imaging spectroscopy in the near infrared region [J].
Baptistao, Mariana ;
de Carvalho Rocha, Werickson Fortunato ;
Poppi, Ronei Jesus .
JOURNAL OF MOLECULAR STRUCTURE, 2011, 1002 (1-3) :167-171
[6]   Electrochemical determination of ascorbic acid and paracetamol in pharmaceutical formulations using a glassy carbon electrode modified with multi-wall carbon nanotubes dispersed in polyhistidine [J].
Dalmasso, Pablo R. ;
Pedano, Maria L. ;
Rivas, Gustavo A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 :732-736
[7]   Electrochemical bisphenol A sensor based on N-doped graphene sheets [J].
Fan, Haixia ;
Li, Yan ;
Wu, Dan ;
Ma, Hongmin ;
Mao, Kexia ;
Fan, Dawei ;
Du, Bin ;
Li, He ;
Wei, Qin .
ANALYTICA CHIMICA ACTA, 2012, 711 :24-28
[8]   Development and validation of a liquid chromatographic method for the determination of ascorbic acid, dehydroascorbic acid and acetaminophen in pharmaceuticals [J].
Gioia, M. G. ;
Andreatta, P. ;
Boschetti, S. ;
Gatti, R. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (02) :331-339
[9]   Dispersion of multi-wall carbon nanotubes in glucose oxidase: Characterization and analytical applications for glucose biosensing [J].
Gutierrez, Fabiana ;
Rubianes, Maria D. ;
Rivas, Gustavo A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :191-197
[10]   Redox polymer covalently modified multiwalled carbon nanotube based sensors for sensitive acetaminophen and ascorbic acid detection [J].
Havens, Nathaniel ;
Trihn, Phong ;
Kim, Daniel ;
Luna, Manelich ;
Wanekaya, Adam K. ;
Mugweru, Amos .
ELECTROCHIMICA ACTA, 2010, 55 (06) :2186-2190