Development and application of an analytical method to quantify odour removal in plastic waste recycling processes

被引:52
作者
Demets, Ruben [1 ,2 ]
Roosen, Martijn [1 ]
Vandermeersch, Lore [3 ]
Ragaert, Kim [2 ]
Walgraeve, Christophe [3 ]
De Meester, Steven [1 ]
机构
[1] Univ Ghent, Fac Biosci Engn, Dept Green Chem & Technol, Lab Circular Proc Engn LCPE, Campus Kortrijk,Graaf Karel de Goedelaan 5, B-8500 Kortrijk, Belgium
[2] Univ Ghent, Fac Engn & Architecture, Ctr Polymer & Mat Technol CPMT, Dept Mat Text & Chem Engn, Technol Pk 130, B-9052 Zwijnaarde, Belgium
[3] Univ Ghent, Fac Biosci Engn, Dept Green Chem & Technol, Environm Organ Chem & Technol EnVOC, Coupure Links 653, B-9000 Ghent, Belgium
关键词
Plastic waste; Odour; Recycling; Gas chromatography; Mass spectrometry; SPME; Purge and trap; SOLID-PHASE MICROEXTRACTION; VOLATILE ORGANIC-COMPOUNDS; CHROMATOGRAPHY-MASS-SPECTROMETRY; HIGH-DENSITY POLYETHYLENE; PACKAGING MATERIALS; DEGRADATION; IDENTIFICATION; THERMOOXIDATION; QUANTIFICATION; TEREPHTHALATE;
D O I
10.1016/j.resconrec.2020.104907
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Europe is strongly committed to the recycling of plastics, especially packaging. In the development of closed loop recycling processes, recyclates must have appropriate properties, including lack of odour. The main objective of this study was to develop a technique to qualitatively and semi-quantitatively analyse the volatile contaminants in these complex plastic waste matrices before and after washing procedures. Three sampling methods were explored, SPME and purge and trap methods (activated carbon with solvent desorption and Tenax-TA with thermal desorption). All analyses were then carried out using gas chromatography - mass spectrometry. SPME was not repeatable due to the heterogeneity of the waste samples and the static character of the method. Solvent desorption with CS2 (RSD 14,5 %) and thermal desorption (RSD 13,4 %), were capable of measuring the removal efficiency of pollutants in a semi-quantitative way. A broad spectrum of chemically different, but mostly apolar volatiles can be detected. In addition, it became clear that also the analysis of the less volatile components is essential, as these are strongly adhered to the hydrophobic polymer matrix. A post-consumer film waste stream was analysed, before and after washing and pelletizing. A general decrease of 97 % and 44 %, was measured with respectively thermal and solvent desorption for the screened components. However, after reprocessing potentially odour-causing compounds are again released or formed, showing the complexity of odour removal processes in plastic recycling.
引用
收藏
页数:14
相关论文
共 58 条
[1]   Comparison of GC-MS Calibration Properties of Volatile Organic Compounds and Relative Quantification Without Calibration Standards [J].
Ahn, Ji-Won ;
Pandey, Sudhir Kumar ;
Kim, Ki-Hyun .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (01) :19-28
[2]   Odour reduction on plastics and its measurement [J].
Bledzki, AK ;
Kessler, A ;
Lieser, J .
POLYMER TESTING, 1999, 18 (01) :63-71
[3]  
Buettner A., 2017, SPRINGER HDB ODOR, DOI [10.1007/978-3-319-26932-0., DOI 10.1007/978-3-319-26932-0]
[4]   Recent developments in the analysis of musty odour compounds in water and wine: A review [J].
Callejon, R. M. ;
Ubeda, C. ;
Rios-Reina, R. ;
Morales, M. L. ;
Troncoso, A. M. .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1428 :72-85
[5]  
Camacho W, 2001, POLYM DEGRAD STABIL, V71, P123
[6]   A comparative and critical evaluation of odour assessment methods on a landfill site [J].
Capelli, Laura ;
Sironi, Selena ;
Del Rosso, Renato ;
Centola, Paolo ;
Il Grande, Massimiliano .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (30) :7050-7058
[7]   ORANGE FLAVOR ABSORPTION INTO VARIOUS POLYMERIC PACKAGING MATERIALS [J].
CHARARA, ZN ;
WILLIAMS, JW ;
SCHMIDT, RH ;
MARSHALL, MR .
JOURNAL OF FOOD SCIENCE, 1992, 57 (04) :963-&
[8]   Evaluation of Mechanical Properties and Volatile Organic Extractable to Investigate LLDPE and LDPE Polymers on Final Packaging for Semisolid Formulation [J].
Cozzi, Arianna Cecilia ;
Briasco, Benedetta ;
Salvarani, Enrico ;
Mannucci, Barbara ;
Fangarezzi, Filippo ;
Perugini, Paola .
PHARMACEUTICS, 2018, 10 (03)
[9]   Quality control in quantification of volatile organic compounds analysed by thermal desorption-gas chromatography-mass spectrometry [J].
Demeestere, Kristof ;
Dewulf, Jo ;
De Roo, Karlien ;
De Wispelaere, Patrick ;
Van Langenhove, Herman .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) :348-357
[10]  
Drager Safety AG & Co. KGaA, 2011, DRAG TUB CMS HDB