Ultrasound-Guided Characterization of Interstitial Ablated Tissue Using RF Time Series: Feasibility Study

被引:13
作者
Imani, Farhad [1 ]
Abolmaesumi, Purang [2 ]
Wu, Mark Z. [4 ]
Lasso, Andras [4 ]
Burdette, Everett C. [3 ]
Ghoshal, Goutam [3 ]
Heffter, Tamas [3 ]
Williams, Emery [3 ]
Neubauer, Paul [3 ]
Fichtinger, Gabor [4 ]
Mousavi, Parvin [4 ]
机构
[1] Queens Univ, Dept Elect & Comp Engn, Kingston, ON K7L 3N6, Canada
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[3] Acoust MedSyst Inc, Champaign, IL 61874 USA
[4] Queens Univ, Sch Comp, Kingston, ON K7L 3N6, Canada
基金
美国国家卫生研究院; 加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Characterization of ablated tissue region; tissue ablation; ultrasound RF time series; IN-VIVO; HEPATOCELLULAR-CARCINOMA; LESIONS; THERAPY; LIVER; TUMORS; COAGULATION; ATTENUATION;
D O I
10.1109/TBME.2013.2240300
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the results of a feasibility study to demonstrate the application of ultrasound RF time series imaging to accurately differentiate ablated and nonablated tissue. For 12 ex vivo and two in situ tissue samples, RF ultrasound signals are acquired prior to, and following, high-intensity ultrasound ablation. Spatial and temporal features of these signals are used to characterize ablated and nonablated tissue in a supervised-learning framework. In cross-validation evaluation, a subset of four features extracted from RF time series produce a classification accuracy of 84.5%, an area under ROC curve of 0.91 for ex vivo data, and an accuracy of 85% for in situ data. Ultrasound RF time series is a promising approach for characterizing ablated tissue.
引用
收藏
页码:1608 / 1618
页数:11
相关论文
共 45 条
[1]  
Aboofazeli M., 2009, P SPIE MED IMAG
[2]   Use of the fractal dimension for the analysis of electroencephalographic time series [J].
Accardo A. ;
Affinito M. ;
Carrozzi M. ;
Bouquet F. .
Biological Cybernetics, 1997, 77 (5) :339-350
[3]  
Adam R, 1998, BRIT J SURG, V85, P1493
[4]   B-scan ultrasound imaging of thermal coagulation in bovine liver: Log envelope slope attenuation mapping [J].
Bevan, PD ;
Sherar, MD .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (03) :379-387
[5]  
Boctor E, 2006, LECT NOTES COMPUT SC, V4191, P405
[6]  
Brown K. T., 2000, P LIV BIL TRACT SURG, P1565
[7]   Radiofrequency ablation versus ethanol injection for early hepatocellular carcinoma: A randomized controlled trial [J].
Brunello, Franco ;
Veltri, Andrea ;
Carucci, Patrizia ;
Pagano, Eva ;
Ciccone, Giovannino ;
Moretto, Paolo ;
Sacchetto, Paola ;
Gandini, Giovanni ;
Rizzetto, Mario .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2008, 43 (06) :727-735
[8]  
Burdette E. C., 2010, P SPIE MED IMAG
[9]   ACOUSTIC PROPERTIES OF LESIONS GENERATED WITH AN ULTRASOUND THERAPY SYSTEM [J].
BUSH, NL ;
RIVENS, I ;
TERHAAR, GR ;
BAMBER, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :789-801
[10]   Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback [J].
Chopra, R ;
Wachsmuth, J ;
Burtnyk, M ;
Haider, MA ;
Bronskill, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04) :827-844