Lowering the limit of detection in high spatial resolution electron beam microanalysis with the microcalorimeter energy dispersive X-ray spectrometer

被引:19
作者
Newbury, D
Wollman, D
Irwin, K
Hilton, G
Martinis, J
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Boulder, CO 80303 USA
关键词
electron probe X-ray microanalysis; energy dispersive X-ray spectrometry; microanalysis; microcalorimetry; scanning electron microscopy; X-ray microanalysis; X-ray spectrometry;
D O I
10.1016/S0304-3991(99)00028-5
中图分类号
TH742 [显微镜];
学科分类号
摘要
Low-beam-energy X-ray microanalysis with the field-emission-gun scanning electron microscope suffers limitations due to physical factors of X-ray generation. Instrumental limitations are imposed by the poor resolution of the conventional semiconductor energy dispersive X-ray spectrometry. Wavelength dispersive X-ray spectrometry provides sufficient resolution to solve spectroscopic problems, but the poor geometric efficiency and the single channel nature of spectrum measurement restrict its practical use for low-beam-energy microanalysis. The microcalorimeter energy dispersive X-ray spectrometer combines high resolution ( < 10 eV) with energy dispersive operation. The utility of this new spectrometer is examined in four categories: (1) qualitative analysis; (2) quantitative analysis; (3) chemical speciation studies, and (4) measurement of trace constituents. For the low-beam-energy regime, the microcalorimeter energy dispersive X-ray spectrometer provides important new performance capabilities for qualitative analysis and chemical speciation studies. However, there are limitations for quantitative studies imposed by detector geometrical characteristics. In addition, trace element detection is impractical below 0.001 mass fraction with low-beam energy ( < 5 keV) because of count rate limitations. Published by Elsevier Science B.V.
引用
收藏
页码:73 / 88
页数:16
相关论文
共 50 条
[41]   Detection and Quantification of Extraterrestrial Platinum Group Element Alloy Micronuggets from Archean Impactite Deposits by Low-Voltage Scanning Electron Microscopy/Energy-Dispersive X-ray Spectrometry [J].
Salge, Tobias ;
Mohr-Westheide, Tanja .
MICROSCOPY AND MICROANALYSIS, 2023, 29 (06) :1837-1846
[42]   Void detection in copper interconnects using energy dispersive x-ray spectroscopy [J].
Tsigkourakos, Menelaos ;
Vandervorst, Wilfried ;
Hantschel, Thomas ;
Franquet, Alexis ;
Conard, Thierry ;
Carbonell, Laureen .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2012, 30 (05)
[43]   Electron-Excited X-ray Microanalysis by Energy Dispersive Spectrometry at 50: Analytical Accuracy, Precision, Trace Sensitivity, and Quantitative Compositional Mapping [J].
Newbury, Dale E. ;
Ritchie, Nicholas W. M. .
MICROSCOPY AND MICROANALYSIS, 2019, 25 (05) :1075-1105
[44]   An investigation of structural degradation of cerebrospinal fluid shunt valves performed using scanning electron microscopy and energy-dispersive x-ray microanalysis [J].
Sgouros, S ;
Dipple, SJ .
JOURNAL OF NEUROSURGERY, 2004, 100 (03) :534-540
[45]   Examination of firearm gunpowders by scanning electron microscopy/energy dispersive X-ray analysis [J].
Burnett, Bryan R. ;
Nunziata, Felice ;
Gentile, Claudio .
JOURNAL OF FORENSIC SCIENCES, 2021, 66 (02) :709-718
[46]   Imaging and Microanalysis of Kidney Stones by Energy Dispersive X-ray Spectroscopy of Al Jawf Region in Saudi Arabia: In Conjunction with X-ray Diffraction (XRD) Study [J].
Almarshad, Hassan ;
Alsharari, Abdalkarem .
JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (04) :655-659
[47]   Analysis of Electron Transparent Beam-Sensitive Samples Using Scanning Electron Microscopy Coupled With Energy-Dispersive X-ray Spectroscopy [J].
Brostrom, Anders ;
Kling, Kirsten Inga ;
Hougaard, Karin Sorig ;
Molhave, Kristian .
MICROSCOPY AND MICROANALYSIS, 2020, 26 (03) :373-386
[48]   An Iterative Qualitative-Quantitative Sequential Analysis Strategy for Electron-Excited X-ray Microanalysis with Energy Dispersive Spectrometry: Finding the Unexpected Needles in the Peak Overlap Haystack [J].
Newbury, Dale E. ;
Ritchie, Nicholas W. M. .
MICROSCOPY AND MICROANALYSIS, 2018, 24 (04) :350-373
[49]   Characterization of covalent immobilization on the surface of optical fibers by scanning electron microscopy and energy dispersive X-ray spectrometry [J].
Wang, Yiming ;
Pang, Xiaofeng ;
Zhang, Yuyu ;
Wang, Hongzhi .
SURFACE AND INTERFACE ANALYSIS, 2009, 41 (10) :775-778
[50]   SCREENING OF CADMIUM AND COPPER PHYTOREMEDIATION ABILITY OF TAGETES ERECTA, USING BIOCHEMICAL PARAMETERS AND SCANNING ELECTRON MICROSCOPY-ENERGY-DISPERSIVE X-RAY MICROANALYSIS [J].
Goswami, Sunayana ;
Das, Suchismita .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2017, 36 (09) :2533-2542