On the inherent data fitting problems encountered in modeling retention behavior of analytes with dual retention mechanism

被引:13
|
作者
Tyteca, Eva [1 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn CHIS IR, Brussels, Belgium
关键词
Retention modeling; Dual retention mechanism; Gradient prediction; Neue-model; Mixed model; PHASE LIQUID-CHROMATOGRAPHY; HYDROPHILIC INTERACTION CHROMATOGRAPHY; SUPERCRITICAL-FLUID CHROMATOGRAPHY; STATIONARY PHASES; GRADIENT ELUTION; OPTIMIZATION; SELECTIVITY; PERFORMANCE; SEPARATION; COLUMNS;
D O I
10.1016/j.chroma.2015.05.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Some valuable insights have been obtained in the inherent fitting problems when trying to predict the retention time of complex, multi-modal retention modes such as encountered in HILIC and SFC. In this study, we used mathematical models with known input parameters to generate different sets of numerical test curves representative for systems exhibiting a complex, non-LSS dual retention behavior. Subsequently, we tried to fit these data sets using some popular (non-linear) literature models. Even in cases where a physical fitting model exists (e.g., the mixed model in case of pure additive adsorptive and partitioning retention), the fitting quality can only be expected to be relatively good (prediction errors expressed in terms of a normalized resolution error sRs) when carefully selecting the scouting runs and the appropriate starting values for the fitting algorithm. The latter can best be done using a comprehensive grid search scanning a wide range of different starting values. This becomes even more important when no good physical model is available and one has to use a non-physical fitting model, such as the empirical Neue-model. The use of higher-order models is found to be quasi indispensable to keep the prediction errors on the order of some Delta R-s = 0.05. Also, the choice of the scouting runs becomes even more important using these higher-order models. For highly retained compounds we recommend using scouting runs with long t(G)/t(0)-values or to include a run with a higher fraction of eluting solvent at the start of the gradient. When trying to predict gradient retention, errors with which the isocratic retention behavior is fitted are much less important for high retention factors k than errors made in the range of k near the one at the point of elution. The results obtained with a so-called segmented Neue-model (containing 7 parameters) were less good and thus practically not interesting (because of the high number of initial runs). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 95
页数:15
相关论文
共 28 条
  • [21] Analysis and modeling of the hydraulic behavior of EGSB reactors with presence and absence of granular biomass at different hydraulic retention times
    Andrea Londono, Yudy
    Victoria Castrillon, Laura
    Pino, Nancy J.
    Lenin Chica, Edwin
    Penuela, Gustavo A.
    INGENIERIA E INVESTIGACION, 2019, 39 (01): : 6 - 14
  • [22] Simultaneous optimization of pH and binary organic composition by grid form modeling of the retention behavior in reversed-phase ultra high-performance liquid chromatography
    Sasaki, Tsukasa
    Todoroki, Kenichiro
    Toyo'oka, Toshimasa
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 251 - 260
  • [23] Modeling the retention mechanism for high-performance liquid chromatography with a chiral ligand mobile phase and enantioseparation of mandelic acid derivatives
    Tong, Shengqiang
    Shen, Mangmang
    Zhang, Hu
    Cheng, Dongping
    Yan, Jizhong
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2085 - 2092
  • [24] Dual Retention Mechanism in Two-Dimensional LC Separations of Barbiturates, Sulfonamides, Nucleic Bases and Nucleosides on Polymethacrylate Zwitterionic Monolithic Micro-Columns
    Magda Staňková
    Pavel Jandera
    Chromatographia, 2016, 79 : 657 - 666
  • [25] Quantitative Structure-Retention Relationship and 3D Molecular Modeling Studies of the Unusual Chromatographic Behavior of Triphenylmethane Derivatives in RPTLC Systems
    Iván Bélai
    Gyula Oros
    Barna Bordás
    JPC – Journal of Planar Chromatography – Modern TLC, 2009, 22 : 255 - 263
  • [26] Quantitative Structure-Retention Relationship and 3D Molecular Modeling Studies of the Unusual Chromatographic Behavior of Triphenylmethane Derivatives in RPTLC Systems
    Belai, Ivan
    Oros, Gyula
    Bordas, Barna
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2009, 22 (04) : 255 - 263
  • [27] Investigation of Retention Behavior of TiOx/Al2O3 Resistive Memory and Its Failure Mechanism Based on Meyer-Neldel Rule
    Banerjee, Writam
    Lu, Nianduan
    Yang, Yang
    Li, Ling
    Lv, Hangbing
    Liu, Qi
    Long, Shibing
    Liu, Ming
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2018, 65 (03) : 957 - 962
  • [28] Preparation and characterization of a novel dual-retention mechanism mixed-mode stationary phase with PEG 400 and succinic anhydride as ligand for protein separation in WCX and HIC modes
    Song, Chao
    Wang, Jianshan
    Zhao, Kailou
    Bai, Quan
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1741 - 1753