On the inherent data fitting problems encountered in modeling retention behavior of analytes with dual retention mechanism

被引:13
|
作者
Tyteca, Eva [1 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn CHIS IR, Brussels, Belgium
关键词
Retention modeling; Dual retention mechanism; Gradient prediction; Neue-model; Mixed model; PHASE LIQUID-CHROMATOGRAPHY; HYDROPHILIC INTERACTION CHROMATOGRAPHY; SUPERCRITICAL-FLUID CHROMATOGRAPHY; STATIONARY PHASES; GRADIENT ELUTION; OPTIMIZATION; SELECTIVITY; PERFORMANCE; SEPARATION; COLUMNS;
D O I
10.1016/j.chroma.2015.05.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Some valuable insights have been obtained in the inherent fitting problems when trying to predict the retention time of complex, multi-modal retention modes such as encountered in HILIC and SFC. In this study, we used mathematical models with known input parameters to generate different sets of numerical test curves representative for systems exhibiting a complex, non-LSS dual retention behavior. Subsequently, we tried to fit these data sets using some popular (non-linear) literature models. Even in cases where a physical fitting model exists (e.g., the mixed model in case of pure additive adsorptive and partitioning retention), the fitting quality can only be expected to be relatively good (prediction errors expressed in terms of a normalized resolution error sRs) when carefully selecting the scouting runs and the appropriate starting values for the fitting algorithm. The latter can best be done using a comprehensive grid search scanning a wide range of different starting values. This becomes even more important when no good physical model is available and one has to use a non-physical fitting model, such as the empirical Neue-model. The use of higher-order models is found to be quasi indispensable to keep the prediction errors on the order of some Delta R-s = 0.05. Also, the choice of the scouting runs becomes even more important using these higher-order models. For highly retained compounds we recommend using scouting runs with long t(G)/t(0)-values or to include a run with a higher fraction of eluting solvent at the start of the gradient. When trying to predict gradient retention, errors with which the isocratic retention behavior is fitted are much less important for high retention factors k than errors made in the range of k near the one at the point of elution. The results obtained with a so-called segmented Neue-model (containing 7 parameters) were less good and thus practically not interesting (because of the high number of initial runs). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 95
页数:15
相关论文
共 28 条
  • [1] Modeling of HILIC retention behavior with theoretical models and new spline interpolation technique
    Tumpa, Anja
    Miskovic, Stefan
    Stanimirovic, Zorica
    Jancic-Stojanovic, Biljana
    Medenica, Mirjana
    JOURNAL OF CHEMOMETRICS, 2017, 31 (09)
  • [2] Novel computational approaches to retention modeling in dual hydrophilic interactions/reversed phase chromatography
    Obradovic, Darija
    Komsta, Lukasz
    Agbabaa, Danica
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1619 (1619)
  • [3] Interconversion of gradient and isocratic retention data in reversed-phase liquid chromatography: Effect of the uptake of eluent modifier on the retention of analytes
    Wang, Mei
    Mallette, Jennifer
    Parcher, Jon F.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (49) : 8630 - 8635
  • [4] Dual hydrophilic interaction-RP retention mechanism on polar columns: Structural correlations and implementation for 2-D separations on a single column
    Jandera, Pavel
    Hajek, Tomas
    Skerikova, Veronika
    Soukup, Jan
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (6-7) : 841 - 852
  • [5] Quantitative structure-retention relationship modeling of gas chromatographic retention times based on thermodynamic data
    Ebrahimi-Najafabadi, Heshmatollah
    McGinitie, Teague M.
    Harynuk, James J.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1358 : 225 - 231
  • [6] Retention Modeling of Gradient Elutions: Application of Iso-to-Grad Approach for LC Systems with Dual-Species Eluent
    Stankov, Vladimir
    Cvetnic, Matija
    Novak Stankov, Mirjana
    Rogosic, Marko
    Bolanca, Tomislav
    Ukic, Sime
    CHROMATOGRAPHIA, 2019, 82 (04) : 749 - 755
  • [7] Modeling Retention Behavior on Analysis of Hallucinogenic Mushrooms Using Hydrophilic Interaction Liquid Chromatography
    Racz, Norbert
    Nagy, Julia
    Jiang, Wen
    Veress, Tibor
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (03) : 230 - 237
  • [8] Studies on the retention mechanism of solutes in hydrophilic interaction chromatography using stoichiometric displacement theory II. HILIC/RPLC dual-retention mechanism of solutes in hydrophilic interaction chromatography over the entire range of water concentration in mobile phase
    Wang, Fei
    Yang, Fan
    Liu, Jiawei
    Bai, Quan
    TALANTA, 2023, 265
  • [9] Elucidation of the retention mechanism on a reverse-phase cyano column by modeling
    Kouskoura, Maria G.
    Hadjipavlou-Litina, Dimitra
    Markopoulou, Catherine K.
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (15) : 1919 - 1929
  • [10] Dual-retention mechanism of dopamine-related compounds on monolithic stationary phase with zwitterion functionality
    Komendova, Martina
    Urban, Jiri
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1618 (1618)