Temperature-Insensitive Hydrogen Sensor With Polarization-Maintaining Photonic Crystal Fiber-Based Sagnac Interferometer

被引:32
作者
Yang, Yuanhong [1 ]
Yang, Fuling [1 ]
Wang, Huan [1 ]
Yang, Wei [1 ]
Jin, Wei [2 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Dept Optoelect Engn, Beijing 100191, Peoples R China
[2] Hong Kong Polytech Univ, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Hydrogen sensor; optical fiber sensor; Pd/Ag composite film; photonic crystal fiber;
D O I
10.1109/JLT.2014.2375362
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We demonstrated a temperature-insensitive hydrogen (H-2) sensor based on polarization-maintaining photonic crystal fiber (PM-PCF). The sensing element is a section of PM-PCF coated with Pd/Ag composite film and is incorporated into a single mode fiber Sagnac loop interferometer. The birefringence of PM-PCF is modulated by H-2 absorption that induces deformation of the Pd/Ag composite film, resulting in shift of the interference spectrum at the output of the Sagnac interferometer. A magnetron facing target sputtering technique with special Pd/Ag rectangular target structures is developed to deposit Pd/Ag composite film on the cylindrical surface of the PM-PCF and the atomic ratio of Pd/Ag composite film is controlled by setting appropriate volume ratio in rectangular target. An empirical linear relationship between atomic ratio and volume ratio was obtained and the H-2 sensing capacity with different atomic ratio of Pd/Ag composite films was investigated experimentally. The results showed that increasing the proportion of Pd in the composite film improves the H-2 detection sensitivity. The sensitivity can also be improved by using as longer length of Pd/Ag coated PM-PCF. With similar to 100 mm long coated PM-PCF as the sensing element, we obtained similar to 1.310 nm shift in the interference spectrum for H-2 concentration from 0 to 1%. The sensitivity coefficient is similar to 131 pm% in the range of 1% to 4% H-2 concentration. The sensor has low temperature dependence and good repeatability.
引用
收藏
页码:2566 / 2571
页数:6
相关论文
共 18 条
[1]   Optical hydrogen sensor based on etched fiber Bragg grating sputtered with Pd/Ag composite film [J].
Dai, Jixiang ;
Yang, Minghong ;
Yu, Xun ;
Lu, Hong .
OPTICAL FIBER TECHNOLOGY, 2013, 19 (01) :26-30
[2]   Temperature Insensitive All-Fiber Compact Polarization-Maintaining Photonic Crystal Fiber Based Interferometer and Its Applications in Fiber Sensors [J].
Dong, Bo ;
Zhou, Da-Peng ;
Wei, Li .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2010, 28 (07) :1011-1015
[3]   Temperature-insensitive strain sensor with polarization-maintaining photonic crystal fiber based Sagnac interferometer [J].
Dong, Xinyong ;
Tam, H. Y. ;
Shum, P. .
APPLIED PHYSICS LETTERS, 2007, 90 (15)
[4]  
Duan W. Q., 2012, P SOC PHOTO-OPT INS, V8561, p0J1
[5]   Optical sensing with photonic crystal fibers [J].
Frazao, Orlando ;
Santos, Jose L. ;
Araujo, Francisco M. ;
Ferreira, Luis A. .
LASER & PHOTONICS REVIEWS, 2008, 2 (06) :449-459
[6]   Multiplexing of polarization-maintaining photonic crystal fiber based Sagnac interferometric sensors [J].
Fu, H. Y. ;
Wong, A. C. L. ;
Childs, P. A. ;
Tam, H. Y. ;
Liao, Y. B. ;
Lu, C. ;
Wai, P. K. A. .
OPTICS EXPRESS, 2009, 17 (21) :18501-18512
[7]   Sagnac loop interferometer based on polarization maintaining photonic crystal fiber with reduced temperature sensitivity [J].
Kim, DH ;
Kang, JU .
OPTICS EXPRESS, 2004, 12 (19) :4490-4495
[8]  
Kim Y. H., 2012, P SOC PHOTO-OPT INS, V8421, p6D1
[9]   Magnetron facing target sputtering system for fabricating single-crystal films [J].
Lin, C ;
Sun, DC ;
Ming, SL ;
Jiang, EY ;
Liu, YG .
THIN SOLID FILMS, 1996, 279 (1-2) :49-52
[10]   Birefringent photonic crystal fibers with zero polarimetric sensitivity to temperature [J].
Martynkien, T. ;
Anuszkiewicz, A. ;
Statkiewicz-Barabach, G. ;
Olszewski, J. ;
Golojuch, G. ;
Szczurowski, M. ;
Urbanczyk, W. ;
Wojcik, J. ;
Mergo, P. ;
Makara, M. ;
Nasilowski, T. ;
Berghmans, F. ;
Thienpont, H. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 94 (04) :635-640