A comparison of signal detection techniques in the multifocal electroretinogram

被引:6
|
作者
Wright, Tom [1 ,2 ]
Nilsson, Josefin [1 ,2 ]
Gerth, Christina [1 ]
Westall, Carol [1 ,3 ]
机构
[1] Hosp Sick Children, Dept Ophthalmol & Vis Sci, Toronto, ON M5G 1X8, Canada
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Clin Neurophysiol, Gothenburg, Sweden
[3] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
关键词
mfERG; signal detection;
D O I
10.1007/s10633-008-9121-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A common task in the analysis of the multifocal electroretinogram (mfERG) is determining which retinal areas have preserved signal in recordings which are attenuated by the effects of disease. Several automated methods have been proposed for signal detection from multifocal recordings, but no systematic study has been published comparing the performance of each. This article compares the sensitivity and specificity of expert human scoring with three different automated methods of mfERG signal detection. Recordings from control subjects were artificially modified to simulate decrease in signal amplitudes (attenuation) as well as total signal loss. Human scorers were able to identify areas with preserved signal at both low and high attenuation levels with a high specificity (minimum 0.99), sensitivities ranged from 0.2 to 0.94. Automated methods based on template correlation performed better than chance at all attenuation levels, with a slide fit method having the best performance. Signal detection based on signal to noise ratio performed poorly. In conclusion automated methods of signal detection can be used to increase signal detection sensitivity in the mfERG.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 50 条
  • [1] A comparison of signal detection techniques in the multifocal electroretinogram
    Tom Wright
    Josefin Nilsson
    Christina Gerth
    Carol Westall
    Documenta Ophthalmologica, 2008, 117 : 163 - 170
  • [2] Detection and monitoring of subclinical ocular siderosis using multifocal electroretinogram
    Sahay, Pranita
    Kumawat, Devesh
    Gupta, Shikha
    Tripathy, Koushik
    Vohra, Rajpal
    Chandra, Mahesh
    Venkatesh, Pradeep
    EYE, 2019, 33 (10) : 1547 - 1555
  • [3] Comparison of DTL and gold cup skin electrodes for recordings of the multifocal electroretinogram
    Theresa Eckermann
    Michael B. Hoffmann
    Khaldoon O. Al-Nosairy
    Documenta Ophthalmologica, 2023, 146 : 67 - 78
  • [4] Comparison of DTL and gold cup skin electrodes for recordings of the multifocal electroretinogram
    Eckermann, Theresa
    Hoffmann, Michael B. B.
    Al-Nosairy, Khaldoon O. O.
    DOCUMENTA OPHTHALMOLOGICA, 2023, 146 (01) : 67 - 78
  • [5] Glaucoma detection by wavelet-based analysis of the global flash multifocal electroretinogram
    Miguel-Jimenez, J. M.
    Boquete, L.
    Ortega, S.
    Rodriguez-Ascariz, J. M.
    Blanco, R.
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (06) : 617 - 622
  • [6] The effects of fundus photography on the multifocal electroretinogram
    Suresh, Sandip
    Tienor, Brian J.
    Smith, Scott D.
    Lee, Michael S.
    DOCUMENTA OPHTHALMOLOGICA, 2016, 132 (01) : 39 - 45
  • [7] The effects of fundus photography on the multifocal electroretinogram
    Sandip Suresh
    Brian J. Tienor
    Scott D. Smith
    Michael S. Lee
    Documenta Ophthalmologica, 2016, 132 : 39 - 45
  • [8] Quantitative assessment of the 103-hexagon multifocal electroretinogram in detection of hydroxychloroquine retinal toxicity
    Adam, Murtaza K.
    Covert, Douglas J.
    Stepien, Kimberly E.
    Han, Dennis P.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (05) : 723 - 729
  • [9] The spatial resolution of the porcine multifocal electroretinogram for detection of laser-induced retinal lesions
    Kyhn, Maria Voss
    Kiilgaard, Jens F.
    Scherfig, Erik
    Prause, Jan U.
    la Cour, Morten
    ACTA OPHTHALMOLOGICA, 2008, 86 (07) : 786 - 793
  • [10] Effects of different degrees of cataract on the multifocal electroretinogram
    W-K Tam
    H Chan
    B Brown
    M Yap
    Eye, 2004, 18 : 691 - 696