Endothelial cell attachment and shear response on biomimetic polymer-coated vascular grafts

被引:21
作者
Dudash, Lynn A. [1 ]
Kligman, Faina [2 ]
Sarett, Samantha M. [1 ]
Kottke-Marchant, Kandice [2 ]
Marchant, Roger E. [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Cleveland Clin, Pathol & Lab Med Inst, Cleveland, OH 44195 USA
关键词
endothelial cells; ePTFE vascular grafts; surface modification; shear stress; GREATER SAPHENOUS-VEIN; BYPASS GRAFTS; CLINICAL-EXPERIENCE; SURFACTANT POLYMERS; STRESS; POLYTETRAFLUOROETHYLENE; ADHESION; ACCESS; EPTFE;
D O I
10.1002/jbm.a.34119
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Endothelial cell (EC) adhesion, shear retention, morphology, and hemostatic gene expression on fibronectin (FN) and RGD fluorosurfactant polymer (FSP)-coated expanded polytetrafluoroethylene grafts were investigated using an in vitro perfusion system. ECs were sodded on both types of grafts and exposed to 8 dyn/cm2 of shear stress. After 24 h, the EC retention on RGD-FSP-coated grafts was 59 +/- 14%, which is statistically higher than the 36 +/- 11% retention measured on FN grafts (p < 0.02). Additionally, ECs on RGD-FSP exhibited a more spread morphology and oriented in the direction of shear stress, as demonstrated by actin fiber staining. This spread morphology has been observed earlier in cells that are adapting to shear stress. Real-time PCR for vascular cell adhesion molecule 1, tissue factor, tissue plasminogen activator, and inducible nitric oxide synthase indicated that the RGD-FSP material did not activate the cells and that shear stress appears to induce a more vasoprotective phenotype, as shown by a significant decrease in VCAM-1 expression, compared with sodded grafts. RGD-FSP-coating allows for a cell layer that is more resistant to physiological shear stress, as shown by the increased cell retention over FN. This shear stable EC layer is necessary for in vivo endothelialization of the graft material, which shows promise to increase the patency of synthetic small diameter vascular grafts. (C) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2012.
引用
收藏
页码:2204 / 2210
页数:7
相关论文
共 50 条
  • [21] MICROVASCULAR ENDOTHELIAL-CELL SODDING OF 1-MM EXPANDED POLYTETRAFLUOROETHYLENE VASCULAR GRAFTS
    AHLSWEDE, KM
    WILLIAMS, SK
    ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (01): : 25 - 31
  • [22] Cell response to PEGylated poly(dopamine) coated liposomes considering shear stress
    Teo, Boon M.
    van der Westen, Rebecca
    Hosta-Rigau, Leticia
    Stadler, Brigitte
    BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2013, 1830 (10): : 4838 - 4847
  • [23] Nitrogen-Rich Plasma-Polymerized Coatings on PET and PTFE Surfaces Improve Endothelial Cell Attachment and Resistance to Shear Flow
    Gigout, Anne
    Ruiz, Juan-Carlos
    Wertheimer, Michael R.
    Jolicoeur, Mario
    Lerouge, Sophie
    MACROMOLECULAR BIOSCIENCE, 2011, 11 (08) : 1110 - 1119
  • [24] Biomimetic modification of polyurethane-based nanofibrous vascular grafts: A promising approach towards stable endothelial lining
    Davoudi, Parivash
    Assadpour, Shiva
    Derakhshan, Mohammad Ali
    Ai, Jafar
    Solouk, Atefeh
    Ghanbari, Hossein
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 80 : 213 - 221
  • [25] Shear-stress-sensing and response mechanisms in vascular endothelial cells
    Ando, Joji
    Yamamoto, Kimiko
    INTERFACE ORAL HEALTH SCIENCE 2009, 2010, : 3 - +
  • [26] Proteomic analysis of vascular endothelial cells in response to laminar shear stress
    Wang, Xiao-Li
    Fu, Alex
    Raghavakaimal, Sreekumar
    Lee, Hon-Chi
    PROTEOMICS, 2007, 7 (04) : 588 - 596
  • [27] Regulation of endothelial cell phenotype by biomimetic matrix coated on biomaterials for cardiovascular tissue engineering
    Prasad, Chennazhy Krishna
    Krishnan, Lissy K.
    ACTA BIOMATERIALIA, 2008, 4 (01) : 182 - 191
  • [28] Thermoplastic polyurethane surface coated with polymer brushes for reduced protein and cell attachment
    Almousa, Rashed
    Xie, Dong
    Chen, Yong
    Li, Jiliang
    Anderson, Gregory G.
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2024, 38 (06) : 758 - 771
  • [29] Dual biofunctional polymer modifications to address endothelialization and smooth muscle cell integration of ePTFE vascular grafts
    Bastijanic, Jennifer M.
    Kligman, Faina L.
    Marchant, Roger E.
    Kottke-Marchant, Kandice
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2016, 104 (01) : 71 - 81
  • [30] Shear stress-induced NO production model of vascular endothelial cell
    Ohashi Y.
    Yamazaki Y.
    Kamiyama Y.
    IEEJ Transactions on Electronics, Information and Systems, 2016, 136 (02): : 116 - 122