Experimental Investigations for Start Up and Maximum Heat Load of Closed Loop Pulsating Heat Pipe

被引:30
|
作者
Sarangi, R. K. [1 ]
Rane, M. V. [2 ]
机构
[1] Don Bosco Inst Technol, Mech Engn Dept, Bombay 400070, Maharashtra, India
[2] Indian Instute Technol Bombay, Mech Engn Dept, Bombay 400076, Maharashtra, India
关键词
Pulsating Heat Pipe; Optimum Fill Ratio; Start up Heat Load; Maximum Heat Load;
D O I
10.1016/j.proeng.2013.01.097
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Startup heat load, maximum heat load and optimum fill ratio of Pulsating Heat Pipe (PHP) of 16 turn, 1 mm ID, 2 mm OD and 9.6 m total length are found out experimentally for water and ethanol as working fluids. PHP is operated in vertical bottom heat mode. Evaporator and condenser temperatures are maintained at 100 degrees C and 28 degrees C respectively. Temperature fluctuations of adiabatic section at startup and maximum heat loads are reported. Experimental results indicate that, startup heat load is independent of fill ratio, but maximum heat load depends on fill ratio. Optimum fill ratio for maximum heat load depends on working fluid for a given PHP and operating temperatures. (C) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 50 条
  • [1] Experimental study on start-up performance of closed loop pulsating heat pipe
    Liu X.-D.
    Chen Y.-P.
    Zhang C.-B.
    Shi M.-H.
    Yuhang Xuebao/Journal of Astronautics, 2011, 32 (10): : 2300 - 2304
  • [2] EXPERIMENTAL INVESTIGATIONS ON THERMAL PERFORMANCE OF A CLOSED LOOP PULSATING HEAT PIPE
    Wang, Yu
    Li, Weiyi
    Wei, Lianyou
    Cao, Binbin
    PROCEEDINGS OF THE ASME MICRO/NANOSCALE HEAT AND MASS TRANSFER INTERNATIONAL CONFERENCE, VOL 3, 2010, : 295 - 303
  • [3] Experimental investigations on operating characteristics of a closed loop pulsating heat pipe
    Wang, Yu
    FRONTIERS IN ENERGY, 2015, 9 (02) : 134 - 141
  • [4] Experimental investigations on operating characteristics of a closed loop pulsating heat pipe
    Yu Wang
    Frontiers in Energy, 2015, 9 : 134 - 141
  • [5] EXPERIMENTAL INVESTIGATION OF CLOSED LOOP PULSATING HEAT PIPE WITH NANOFLUIDS
    Jamshidi, Hamed
    Arabnejad, Sajad
    Shafii, Mohammad Behshad
    Saboohi, Yadollah
    Rasoulian, Ramin
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 1, 2009, : 675 - 683
  • [6] EXPERIMENTAL INVESTIGATIONS ON THE EFFECT OF INFLUENCING PARAMETERS ON OPERATING REGIME OF A CLOSED LOOP PULSATING HEAT PIPE
    Patel, Vipul M.
    Mehta, Hemantkumar B.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2019, 26 (04) : 333 - 344
  • [7] Experimental Investigations on Thermal Performance of a Multi-turn Closed Loop Pulsating Heat Pipe
    Wang, Yu
    Li, Weiyi
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 5854 - 5860
  • [8] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [9] Correlation to Predict the Maximum Heat Flux of a Vertical Closed-Loop Pulsating Heat Pipe
    Kammuang-Lue, Niti
    Sakulchangsatjatai, Phrut
    Terdtoon, Pradit
    Mook, D. Joseph
    HEAT TRANSFER ENGINEERING, 2009, 30 (12) : 961 - 972
  • [10] Experimental investigations on pulsating heat pipe
    Gamit, Harshal
    More, Vinayak
    Mukund, Bade
    Mehta, H. B.
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 3186 - 3191