Electrochemical piezoelectric retisable immunosensor for aflatoxin B1 detection

被引:34
|
作者
Chauhan, Ruchika [1 ]
Singh, Jay [2 ]
Solanki, Pratima R. [3 ]
Basu, T. [1 ]
O'Kenriedy, Richard [4 ]
Malhotra, B. D. [5 ]
机构
[1] Amity Univ Uttar Pradesh, Amity Inst Nanotechnol, Noida, India
[2] Delhi Technol Univ, Dept Appl Chem & Polymer Technol, Delhi 110042, India
[3] Jawaharlal Nehru Univ, Special Ctr Nano Sci, New Delhi 110067, India
[4] Dublin City Univ, Biomed Diagnost Inst, Dublin 9, Ireland
[5] Delhi Technol Univ, Dept Biotechnol, Delhi 110042, India
关键词
Aflatoxin B1; Immunosensor; EQCM; Fe-3; O-4; NPs; Au-Fe3O4; QUARTZ-CRYSTAL MICROBALANCE; MAGNETIC NANOPARTICLES; GOLD NANOPARTICLES; CARBON NANOTUBES; RAPID DETECTION; BIOSENSOR; B-1; IMMUNOASSAY; OCHRATOXIN; SURFACE;
D O I
10.1016/j.bej.2015.07.002
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A competitive, reusable, reliable and sensitive immunosensor based on electrochemical quartz crystal microbalance (EQCM) was developed for the detection of aflatoxin B1 (AFB1). The sensing platform was developed using a primary monoclonal anti-aflatoxin antibody (anti AFB1) covalently immobilized on a monolayer of 4-amino thiophenol self assembled on a gold coated quartz crystal electrode (anti AFB1 /4-ATP/Au). The reusability was achieved by a sandwiched system using secondary rabbit-immunoglobulin antibodies (r-IgGs) tagged with core shell of gold coated iron oxide nanoparticles (r-IgG-Au-Fe3O4), which can be used to regenerate the bioelectrode. A competitive mode was employed, between free and coated AFB1 for fixed concentration of nanoparticle conjugate (r-IgG-Au-Fe3O4). After the competitive interaction, immunoelectrode was washed with phosphate saline buffer (PBS) at pH 7.4 and examined by electrochemical quartz crystal microbalance-cyclic voltammetry (EQCM-CV). Under the optimized conditions, the fabricated immunosensor can be used to detect AFB1 quantitatively with a linear range of 0.05 to 5 ngmL(-1). For reliability, the fabricated immuno sensor was tested using cereal samples spiked with different concentrations of AFB1. In addition, this immuno electrode displays good reproducibility, and storage stability. The above immunosensor was regenerated with negligible loss in activity through removal of the r-IgG-Au-Fe3O4 conjugate using a strong magnet. It is shown that the AFB1/BSA/aAFB1/4-ATP/Au immuno sensor is a new approach for developing sensitive reliable and reusable electrochemical piezoelectric immunosensors. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 50 条
  • [41] Electrochemical immunosensor based on AuNPs/Zn/Ni-ZIF-8-800@graphene for rapid detection of aflatoxin B1 in peanut oil
    Wang, Na
    Liu, Qingquing
    Hu, Xiaofei
    Wang, Fan
    Hu, Mei
    Yu, Qiuying
    Zhang, Gaiping
    ANALYTICAL BIOCHEMISTRY, 2022, 650
  • [42] A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1
    Moon, Jihea
    Kim, Giyoung
    Lee, Sangdae
    MATERIALS, 2012, 5 (04): : 634 - 643
  • [43] Gold nanobipyramids integrated ultrasensitive optical and electrochemical biosensor for Aflatoxin B1 detection
    Bhardwaj, Hema
    Sumana, Gajjala
    Marquette, Christophe A.
    TALANTA, 2021, 222
  • [44] An aptamer-based dipstick assay for the rapid and simple detection of aflatoxin B1
    Shim, Won-Bo
    Kim, Min Jin
    Mun, Hyoyoung
    Kim, Min-Gon
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 288 - 294
  • [45] Electrochemical immunosensor based on poly (3,4-ethylenedioxythiophene) modified with gold nanoparticle to detect aflatoxin B1
    Sharma, Arati
    Kumar, A.
    Khan, Raju
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 76 : 802 - 809
  • [46] Studies towards the development of a screen-printed carbon electrochemical immunosensor array for mycotoxins:: A sensor for aflatoxin B1
    Pemberton, R. M.
    Pittson, R.
    Biddle, N.
    Drago, G. A.
    Hart, J. P.
    ANALYTICAL LETTERS, 2006, 39 (08) : 1573 - 1586
  • [47] A disposable ratiometric electrochemical aptasensor with exonuclease I-powered target recycling amplification for highly sensitive detection of aflatoxin B1
    Cui, Haining
    An, Keqi
    Wang, Chengquan
    Chen, Yangfang
    Jia, Suli
    Qian, Jing
    Hao, Nan
    Wei, Jie
    Wang, Kun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 355
  • [48] Fabrication of gold/graphene nanostructures modified ITO electrode as highly sensitive electrochemical detection of Aflatoxin B1
    Althagafi, Ismail I.
    Ahmed, Saleh A.
    El-Saidid, Waleed A.
    PLOS ONE, 2019, 14 (01):
  • [49] A non-enzymatic nanomagnetic electro-immunosensor for determination of Aflatoxin B1 as a model antigen
    Masoomi, Leila
    Sadeghi, Omid
    Banitaba, Mohammad Hossein
    Shahrjerdi, Akram
    Davarani, Saied Saeed Hosseiny
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 1122 - 1127
  • [50] Functional nanomaterials based immunological detection of aflatoxin B1: a review
    Zha, Y-H
    Zhou, Y.
    WORLD MYCOTOXIN JOURNAL, 2020, 13 (02) : 151 - 162