Measurement of signal-to-noise and contrast-to-noise in the fBIRN multicenter imaging study

被引:153
作者
Magnotta, Vincent A.
Friedman, Lee
Birn, First
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[2] MIND Inst, Albuquerque, NM 87106 USA
[3] NIH, Funct Imaging Schizophrenia Testbed Biomed Inform, Natl Ctr Res Resources, Bethesda, MD 20892 USA
关键词
image quality; signal-to-noise (S/N); magnetic resonance imaging (MRI);
D O I
10.1007/s10278-006-0264-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ability to analyze and merge data across sites, vendors, and field strengths depends on one's ability to acquire images with the same image quality including image smoothness, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). SNR can be used to compare different magnetic resonance scanners as a measure of comparability between the systems. This study looks at the SNR and CNR ratios in structural fast spin-echo T-2-weighted scans acquired in five individuals across ten sites that are part of Functional Imaging Research of Schizophrenia Testbed Biomedical Informatics Research Network (fBIRN). Different manufacturers, field strengths, gradient coils, and RF coils were used at these sites. The SNR of gray matter was fairly uniform (41.3-43.3) across scanners at 1.5 T. The higher field scanners produced images with significantly higher SNR values (44.5-108.7 at 3 T and 50.8 at 4 T). Similar results were obtained for CNR measurements between gray/white matter at 1.5 T (9.5-10.2), again increasing at higher fields (10.1-28.9 at 3 T and 10.9 at 4 T).
引用
收藏
页码:140 / 147
页数:8
相关论文
共 23 条
[1]  
ANDREASEN NC, 1992, J NEUROPSYCH CLIN N, V4, P125
[2]  
ANDREASEN NC, 1993, J NEUROPSYCH CLIN N, V5, P121
[3]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[4]   Practical aspects of birdcage coils [J].
Doty, FD ;
Entzminger, G ;
Hauck, CD ;
Staab, JP .
JOURNAL OF MAGNETIC RESONANCE, 1999, 138 (01) :144-154
[5]  
FRIEDMAN L, 2004, INT SOC MAGNETIC RES, P1074
[6]   MR imaging of human brain at 3.0 T: Preliminary report on transverse relaxation rates and relation to estimated iron content [J].
Gelman, N ;
Gorell, JM ;
Barker, PB ;
Savage, RM ;
Spickler, EM ;
Windham, JP ;
Knight, RA .
RADIOLOGY, 1999, 210 (03) :759-767
[7]  
GEORGIADES C, 1999, RADIOLOGY, V210, P759
[8]   Quantification of errors in volume measurements of the caudate nucleus using magnetic resonance imaging [J].
Gurleyik, K ;
Haacke, EM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :353-363
[9]  
Ibanez L., 2003, ITK SOFTWARE GUIDE I
[10]   MR relaxation times in human brain: Measurement at 4 T [J].
Jezzard, P ;
Duewell, S ;
Balaban, RS .
RADIOLOGY, 1996, 199 (03) :773-779