Comparison of 1.0 M Gadobutrol and 0.5 M Gadopentetate Dimeglumine-Enhanced Magnetic Resonance Imaging in Five Hundred Seventy-Two Patients With Known or Suspected Liver Lesions Results of a Multicenter, Double-Blind, Interindividual, Randomized Clinical Phase-III Trial

被引:33
作者
Hammerstingl, Renate [1 ]
Adam, Gerhard [2 ]
Ayuso, Juan-Ramon [3 ]
Van Beers, Bernard [4 ]
Belfiore, Giuseppe [5 ]
Bellin, Marie-France [6 ]
Bongartz, Georg [7 ]
Ernst, Olivier [8 ]
Frericks, Bernd [22 ]
Giuseppetti, Gianmarco [9 ]
Heinz-Peer, Gertrud [11 ]
Laghi, Andrea [13 ]
Martin, Julio [12 ]
Pering, Christiane [14 ]
Reimer, Peter [15 ]
Richter, Goetz-Martin [17 ]
Roemer, Frank W. [18 ]
Schaefer, Fritz K. W. [10 ]
Vilgrain, Valerie [19 ]
Vogl, Thomas J. [1 ]
Weishaupt, Dominik [20 ]
Wall, Alexander [21 ]
Zech, Christoph J. [16 ]
Tombach, Bernd [21 ,23 ]
机构
[1] Univ Frankfurt Klinikum, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Univ Klinikum Hamburg Eppendorf, Radiol Klin & Poliklin, Hamburg, Germany
[3] Hosp Clin & Prov Serv Radiodiagnost, Barcelona, Spain
[4] Univ Catholique Louvain, St Luc Univ Hosp, Dept Radiol, B-1200 Brussels, Belgium
[5] Azienda Osped Rilievo Nazl Alta, Speciallizzaz AORN, Dipartimento Diagnost Immagini, Caserta, Italy
[6] Hop Paul Brousse, Serv Radiol, Villejuif, France
[7] Univ Basel Hosp, Dept Med Radiol, CH-4031 Basel, Switzerland
[8] Hosp Huriez Serv Radiol, Lille, France
[9] Osped Reg Torrette, Inst Radiol, Ctr Risonanza Magnet, Ancona, Italy
[10] Univ Klinikum Schleswig Holstein, Radiol Diagnost Klin, Kiel, Germany
[11] Univ Klin Radiodiagnost, Allgemeines Krankenhaus Stadt Wien, Vienna, Austria
[12] Corp Sanitaria, UDIAT Parc Tauli, Ctr Diagnost, Barcelona, Spain
[13] Policlin Umberto 1, Ist Radiol Cent, Rome, Italy
[14] Bayer Schering Pharma, BU Diagnost Imaging, Berlin, Germany
[15] Stadt Klinikum Karlsruhe, Zent Inst Bildgebende Diagnost, Karlsruhe, Germany
[16] Univ Munich, Klinikum Grosshadern, Radiol Klin & Poliklin, D-8000 Munich, Germany
[17] Univ Heidelberg Hosp, Zentrum Chirurg, Heidelberg, Germany
[18] Klinikum Augsburg, Klin Diagnost Radiol & Neuroradiol, Augsburg, Germany
[19] Hop Beaujon, Clichy, France
[20] Univ Spital Zurich, MRI Zentrum, Dept Med Radiol, Zurich, Switzerland
[21] Univ Munster, Inst Klin Radiol, D-4400 Munster, Germany
[22] Univ Klinikum Benjamin Franklin, Berlin, Germany
[23] Klinikum Osnabruck, Rontgen & Strahlenklin, Osnabruck, Germany
关键词
gadobutrol; gadopentetate; liver lesions; MRI; diagnostic differentiation noninferiority; safety profiles; NEPHROGENIC SYSTEMIC FIBROSIS; DIGITAL-SUBTRACTION-ANGIOGRAPHY; CHRONIC-RENAL-FAILURE; GD-EOB-DTPA; GADOBENATE DIMEGLUMINE; GADOLINIUM EXPOSURE; CHELATE GADOBUTROL; CIRRHOTIC LIVER; CONTRAST AGENTS; MRI;
D O I
10.1097/RLI.0b013e318198a0ae
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic efficacy (accuracy, sensitivity, specificity) of 1.0 M gadobutrol versus 0.5 M gadopentetate for the classification of lesions as either benign or malignant in patients with known or suspected liver lesions. Methods and Materials: A multicenter, phase-III, randomized, interindividually controlled comparison study with blinded reader evaluation was performed to investigate the diagnostic efficacy of a bolus injection of 1.0 M gadobutrol compared with 0.5 M gadopentetate at a dose of 0.1 mmol Gd/kg BW: The imaging protocol included a dynamic 3D-evaluation, static conventional, and fat saturated T1-weighted sequences. MR datasets were evaluated by 3 independent radiologists. The standard of reference was defined by an independent truth panel (radiologist or hepatologist). The safety evaluation included adverse events, vital signs, and physical examination. Results: A total of 497 of 572 patients were eligible for the final efficacy analysis. Noninferiority of gadobutrol-enhanced magnetic resonance imaging (MRI) for the classification of liver lesions was demonstrated on the basis of diagnostic accuracy determined by the on-site investigators (-0.098, 0.021) as well as for the average reader of the blinded evaluation (-0.096, 0.014) (95% confidence interval), compared with the predefined standard of reference. Very similar increases in sensitivity (ranging from similar to 10% to similar to 55%) and specificity (ranging from similar to 1%-similar to 18%) compared with precontrast MRI were also observed for the 2 contrast agent groups, with maximum differences of 4%. Very similar, low rates of adverse events were recorded for each of the 2 groups. No clinically relevant changes in vital signs or the results of the physical examination were observed in any patient. Conclusion: This study documents evidence for the noninferiority of a single i.v. bolus injection of 1.0 M gadobutrol (0.1 mmol/kg body weight) to 0.5 M gadopentetate (0.1 mmol/kg body weight) in the diagnostic assessment of liver lesions with contrast-enhanced MRI. The known excellent safety profile of gadobutrol was confirmed in this clinical trial and is similar to that of gadopentetate.
引用
收藏
页码:168 / 176
页数:9
相关论文
共 44 条
[11]   Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease:: a prospective, multi-centre blinded comparison with digital subtraction angiography [J].
Hentsch, A ;
Aschauer, MA ;
Balzer, JO ;
Brossmann, J ;
Busch, HP ;
Davis, K ;
Douek, P ;
Ebner, F ;
van Engelshoven, JMA ;
Gregor, M ;
Kersting, C ;
Knüsel, PR ;
Leen, E ;
Leiner, T ;
Loewe, C ;
McPherson, S ;
Reimer, P ;
Schäfer, FKW ;
Taupitz, M ;
Thurnher, SA ;
Tombach, B ;
Wegener, R ;
Weishaupt, D ;
Meaney, JFM .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2103-2114
[12]   Intraindividual comparison of gadopentetate dimeglumine, gadobenate dimeglumine, and gadobutrol for pelvic 3D magnetic resonance angiography [J].
Herborn, CU ;
Lauenstein, TC ;
Ruehm, SG ;
Bosk, S ;
Debatin, JF ;
Goyen, M .
INVESTIGATIVE RADIOLOGY, 2003, 38 (01) :27-33
[13]   Improved detection of focal liver lesions at MR imaging: Multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings [J].
Huppertz, A ;
Balzer, T ;
Blakeborough, A ;
Breuer, L ;
Giovagnoni, A ;
Heinz-Peer, G ;
Laniado, M ;
Manfredi, RM ;
Mathieu, DG ;
Mueller, D ;
Reimer, P ;
Robinson, PJ ;
Strotzer, M ;
Taupitz, M ;
Vogl, TJ .
RADIOLOGY, 2004, 230 (01) :266-275
[14]   Gadobutrol, a highly concentrated MR-imaging contrast agent,agent its physicochemical characteristics and the basis for its use in contrast-enhanced MR angiography and perfusion imaging [J].
Huppertz, A ;
Rohrer, M .
EUROPEAN RADIOLOGY, 2004, 14 :M12-M18
[15]   Surgically staged focal liver lesions: Accuracy and reproducibility of dual-phase helical CT for detection and characterizatiton [J].
Kamel, IR ;
Choti, MA ;
Horton, KM ;
Braga, HJV ;
Birnbaum, BA ;
Fishman, EK ;
Thompson, RE ;
Bluemke, DA .
RADIOLOGY, 2003, 227 (03) :752-757
[16]   Nephrogenic systemic fibrosis: A serious iatrogenic disease of renal failure patients [J].
Khurram, Misbah ;
Skov, Lone ;
Rossen, Kristian ;
Thomsen, Henrik S. ;
Marckmann, Peter .
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2007, 41 (06) :565-566
[17]   The value of gadobenate dimeglumine-enhanced delayed phase MR imaging for characterization of hepatocellular nodules in the cirrhotic liver [J].
Kim, Jung Im ;
Lee, Jeong Min ;
Choi, Jin Young ;
Kim, Young Kon ;
Kim, Se Hyung ;
Lee, Jae Young ;
Han, Joon Koo ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2008, 43 (03) :202-210
[18]   Assessment of utilization and pharmacovigilance based on spontaneous adverse event reporting of gadopentetate dimeglumine as a magnetic resonance contrast agent after 45 million administrations and 15 years of clinical use [J].
Knopp, MV ;
Balzer, T ;
Esser, MC ;
Kashanian, FK ;
Paul, P ;
Niendorf, HP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (06) :491-499
[19]   PERIPHERAL WASHOUT - A SIGN OF MALIGNANCY ON DYNAMIC GADOLINIUM-ENHANCED MR-IMAGES OF FOCAL LIVER-LESIONS [J].
MAHFOUZ, AE ;
HAMM, B ;
WOLF, KJ .
RADIOLOGY, 1994, 190 (01) :49-52
[20]   MALIGNANCIES IN PATIENTS WITH CIRRHOSIS - CT SENSITIVITY AND SPECIFICITY IN 200 CONSECUTIVE TRANSPLANT PATIENTS [J].
MILLER, WJ ;
BARON, RL ;
DODD, GD ;
FEDERLE, MP .
RADIOLOGY, 1994, 193 (03) :645-650