Nd:YAG laser penetration into cast titanium and gold alloy with different surface preparations

被引:25
作者
Watanabe, I
Baba, N
Chang, J
Chiu, Y
机构
[1] Baylor Coll Dent, Texas A&M Univ Syst Hlth Sci Ctr, Dept Biomat Sci, Dallas, TX 75246 USA
[2] Nagasaki Univ, Grad Sch Biomed Sci, Dept Dev & Reconstruct Med, Div Fixed Prosthodont & Oral Rehabil, Nagasaki 852, Japan
关键词
laser penetration; titanium; gold alloy; casting;
D O I
10.1111/j.1365-2842.2006.01512.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study investigated the effect of surface preparation on the Nd:YAG laser penetration into cast titanium and gold alloy. Cast blocks of each metal were given four different surface preparations: (i) coloured with black marker; (ii) air-abraded with 50 mu m Al2O3; (iii) ground with SiC points and (iv) polished with 1 mu m Al2O3 (mirror-polished). Two blocks with each of the surface preparations were abutted and laser-welded at their interface using the voltages of 210-260 V in increments of 10 V. After the welded blocks were mechanically separated, the laser penetration was measured using computer graphics. Regardless of the surface preparation, an increase in voltage increased the laser penetration for both metals. The laser penetration into titanium prepared with black marker and air-abrasion was significantly deeper than into the titanium ground with SiC points and mirror-polished. Although there were no statistical differences in penetration among the surface preparations for the gold alloy, the penetration in the mirror-polished specimens was shallower than any of the other preparation methods at higher voltages of 240-260 V. The results obtained in this study suggested that broken metal frameworks with finished surfaces should be painted with black marker or air-abraded before laser welding.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 10 条
[1]   Penetration depth into dental casting alloys by Nd:YAG laser [J].
Baba, N ;
Watanabe, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (01) :64-68
[2]   Mechanical strength of laser-welded cobalt-chromium alloy [J].
Baba, N ;
Watanabe, I ;
Liu, J ;
Atsuta, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 69B (02) :121-124
[3]  
Ishikawa Masatoshi, 2002, J Prosthodont, V11, P49, DOI 10.1111/j.1532-849X.2002.00049.x
[4]  
Jemt T, 2000, INT J PROSTHODONT, V13, P282
[5]   Joint strength of laser-welded titanium [J].
Liu, J ;
Watanabe, I ;
Yoshida, K ;
Atsuta, M .
DENTAL MATERIALS, 2002, 18 (02) :143-148
[6]   Application of cast iron-platinum keeper to a collapsible denture for a patient with constricted oral opening: A clinical report [J].
Ohkubo, C ;
Watanabe, I ;
Tanaka, Y ;
Hosoi, T .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (01) :6-9
[7]   STUDIES ON LASER-WELDED AND PLASMA-WELDED TITANIUM [J].
ROGGENSACK, M ;
WALTER, MH ;
BONING, KW .
DENTAL MATERIALS, 1993, 9 (02) :104-107
[8]  
TOGAYA T, 1999, QUINT DENT TECH, V24, P740
[9]   Application of cast magnetic attachments to sectional complete dentures for a patient with microstomia: A clinical report [J].
Watanabe, I ;
Tanaka, Y ;
Ohkubo, C ;
Miller, AW .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (06) :573-577
[10]   Effects of heat treatments on mechanical strength of laser-welded equi-atomic AuCu-6at%Ga alloy [J].
Watanabe, I ;
Liu, J ;
Atsuta, M .
JOURNAL OF DENTAL RESEARCH, 2001, 80 (09) :1813-1817