Application of a 3-dimensional printed navigation template in Bernese periacetabular osteotomies A cadaveric study

被引:23
作者
Zhou, You [1 ]
Kang, Xiaopeng [1 ]
Li, Chuan [2 ]
Xu, Xiaoshan [2 ]
Li, Rong [3 ]
Wang, Jun [3 ]
Li, Wei [4 ]
Luo, Haotian [2 ]
Lu, Sheng [2 ]
机构
[1] Kunming Childrens Hosp, Dept Orthopaed, Kunming 650000, Yunnan, Peoples R China
[2] Kunming Gen Hosp Chengdu Mil Reg, Dept Orthopaed, 212 Daguan Rd, Kunming 650000, Yunnan, Peoples R China
[3] Kunming Med Univ, Affiliated Hosp 1, Dept Orthopaed, Kunming 650000, Yunnan, Peoples R China
[4] Kunming Municipal Hosp Tradit Chinese Med, Dept Orthopaed, Kunming 650000, Yunnan, Peoples R China
关键词
3D printing; dysplasia; hip; navigation; periacetabular osteotomy; FEMOROACETABULAR IMPINGEMENT; ACETABULAR OSTEOTOMY; HIP; SURGERY; DYSPLASIA; PROGNOSIS; ACCURACY; DISEASE;
D O I
10.1097/MD.0000000000005557
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the present study was to describe the application of 3D printed templates for intraoperative navigation and simulation of periacetabular osteotomies (PAOs) in a cadaveric model. Five cadaveric specimens (10 sides) underwent thin-slice computed tomographic scans of the ala of iliumdownwards to the proximal end of femoral shaft. Bernese PAO was performed. Using Mimics v10.1 software (Materialise, Leuven, Belgium), 3D computed tomographic reconstructions were created and the 4 standard PAO bone cuts-ischial, pubic, anterior, and posterior aspects of the ilium-as well as rotation of the dislocated acetabular bone blocks were simulated for each specimen. Using these data, custom 3D printed bone-drilling templates of the pelvis were manufactured, to guide surgical placement of the PAO bone cuts. An angle fix wedge was designed and printed, to help accurately achieve the predetermined rotation angle of the acetabular bone block. Each specimen underwent a conventional PAO. Preoperative, postsimulation, and postoperative lateral center-edge angles, acetabular indices, extrusion indices, and femoral head coverage were measured and compared; P and t values were calculated for above-mentioned measurements while comparing preoperative and postoperative data, and also in postsimulation and postoperative data comparison. All 10 PAO osteotomies were successfully completed using the 3D printed bone-drilling template and angle fix wedge. No osteotomy entered the hip joint and a single posterior column fracture was observed. Comparison of preoperative and postoperative measurements of the 10 sides showed statistically significant changes, whereas no statistically significant differences between postsimulation and postoperative values were noted, demonstrating the accuracy and utility of the 3D printed templates. The application of patient-specific 3D printed bone-drilling and rotation templates in PAO is feasible and may facilitate improved clinical outcomes, through the use of precise presurgical planning and reduced surgical complications with the precisely guided bone drilling.
引用
收藏
页数:6
相关论文
共 26 条
  • [1] Improved Accuracy with 3D Planning and Patient-Specific Instruments During Simulated Pelvic Bone Tumor Surgery
    Cartiaux, Olivier
    Paul, Laurent
    Francq, Bernard G.
    Banse, Xavier
    Docquier, Pierre-Louis
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (01) : 205 - 213
  • [2] CT with 3D rendering of the tendons of the foot and ankle: Technique, normal anatomy, and disease
    Choplin, RH
    Buckwalter, KA
    Rydberg, J
    Farber, JM
    [J]. RADIOGRAPHICS, 2004, 24 (02) : 343 - 356
  • [3] Computer-Assisted Femoral Head-Neck Osteochondroplasty Using a Surgical Milling Device An In Vitro Accuracy Study
    Ecker, Timo M.
    Puls, Marc
    Steppacher, Simon D.
    Bastian, Johannes D.
    Keel, Marius J. B.
    Siebenrock, Klaus A.
    Tannast, Moritz
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (02) : 310 - 316
  • [4] Ferdinando A, 2016, EFFORT OPEN REV, V1, P121
  • [5] Hip disease and the prognosis of total hip replacements - A review of 53 698 primary total hip replacements reported to the Norwegian Arthroplasty Register 1987-99
    Furnes, O
    Lie, SA
    Espehaug, B
    Vollset, SE
    Engesaeter, LB
    Havelin, LI
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (04): : 579 - 586
  • [6] GANZ R, 1988, CLIN ORTHOP RELAT R, P26
  • [7] Splinting vs surgery in the treatment of carpal tunnel syndrome - A randomized controlled trial
    Gerritsen, AAM
    de Vet, HCW
    Scholten, RJPM
    Bertelsmann, FW
    de Krom, MCTFM
    Bouter, LM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (10): : 1245 - 1251
  • [8] HARRIS WH, 1986, CLIN ORTHOP RELAT R, P20
  • [9] Customised osteotomy guides and endoprosthetic reconstruction for periacetabular tumours
    Holzapfel, Boris Michael
    Pilge, Hakan
    Prodinger, Peter Michael
    Toepfer, Andreas
    Mayer-Wagner, Susanne
    Hutmacher, Dietmar Werner
    von Eisenhart-Rothe, Ruediger
    Rudert, Maximilian
    Gradinger, Reiner
    Rechl, Hans
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1435 - 1442
  • [10] Hussell JG, 1999, CLIN ORTHOP RELAT R, P81