Changes of intraaortic balloon volume during pumping in a mock circulation system

被引:6
|
作者
Sakamoto, T
Akamatsu, H
Swartz, MT
Shoji, Y
Kazama, S
Fujiyoshi, K
Hashiguchi, Y
Suzuki, A
Miyashita, M
Arai, H
Suzuki, A
机构
[1] ST LOUIS UNIV,ST LOUIS,MO 63103
[2] KOHDEN TOKYO CORP,TOKYO,JAPAN
[3] AISIN HUMAN SYST CO LTD,NAGOYA,AICHI,JAPAN
关键词
intraaortic balloon pumping; mechanical circulatory support; diastolic augmentation; balloon volume;
D O I
10.1111/j.1525-1594.1996.tb04439.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of hemodynamic changes on intraaortic balloon (IAB) volumes were studied experimentally using a helium tachometer in a mock circulatory system. The IAB volume decreased with increases in the heart rate and mean aortic pressure, but the degree of reduction in the IAB volume was different among 4 commercially available IAB drivers. Improvements in IAB consoles are needed to compliment the progress made in percutaneous techniques for IAB insertion resulting in smaller balloons.
引用
收藏
页码:275 / 277
页数:3
相关论文
共 50 条
  • [31] Transbrachial Intraaortic Balloon Pumping: The Forgotten Vessel? Reply
    Jeevanandam, Valluvan
    ANNALS OF THORACIC SURGERY, 2016, 101 (04): : 1636 - 1636
  • [32] Transesophageal atrial pacing as a trigger for intraaortic balloon pumping
    Roth, JV
    ANESTHESIOLOGY, 1997, 86 (01) : 264 - 264
  • [33] AN OPTIMAL-CONTROL ALGORITHM FOR INTRAAORTIC BALLOON PUMPING
    BARNEA, O
    SMITH, B
    MOORE, TW
    JARON, D
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1419 - 1420
  • [34] COMPLICATION OF INTRAAORTIC BALLOON PUMPING IN A PEDIATRIC-PATIENT
    VANDEWAL, HJCM
    BENNINK, GBWE
    BENATAR, AA
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1995, 9 (10) : 602 - 603
  • [35] VASCULAR COMPLICATIONS ASSOCIATED WITH THE USE OF INTRAAORTIC BALLOON PUMPING
    SANFELIPPO, PM
    BAKER, NH
    EWY, HG
    MOORE, PJ
    THOMAS, JW
    BRAHOS, GJ
    MCVICKER, RF
    TEXAS HEART INSTITUTE JOURNAL, 1987, 14 (02) : 178 - 182
  • [36] INTERHOSPITAL TRANSPORT OF PATIENTS WITH ONGOING INTRAAORTIC BALLOON PUMPING
    LOCICERO, J
    HARTZ, RS
    SANDERS, JH
    HUETER, DC
    MCDONOUGH, TJ
    MICHAELIS, LL
    AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (01): : 59 - 61
  • [37] EFFECTS OF INFRARENAL INTRAAORTIC BALLOON PUMPING ON RENAL HEMODYNAMICS
    AGISHI, T
    TERAOKA, S
    SANAKA, T
    OTA, K
    KIDNEY INTERNATIONAL, 1983, 23 (01) : 241 - 241
  • [38] Transesophageal atrial pacing as a trigger for intraaortic balloon pumping
    Broka, SM
    Ducart, AR
    Collard, EL
    Thiry, DJ
    Louagie, YAG
    Delire, VR
    Mayne, AJ
    Randour, PR
    Joucken, KL
    ANESTHESIOLOGY, 1996, 84 (02) : 473 - 473
  • [39] Transbrachial intraaortic balloon pumping in severe peripheral atherosclerosis
    Onorati, Francesco
    Impiombato, Barbara
    Ferraro, Alessandro
    Comi, Maria Caterina
    Spaccarotella, Carmen
    Indolfi, Ciro
    Renzulli, Attilio
    ANNALS OF THORACIC SURGERY, 2007, 84 (01): : 264 - 266
  • [40] EFFECTS OF INTRAAORTIC BALLOON PUMPING DURING RIGHT VENTRICULAR INFLOW OBSTRUCTION IN THE NEWBORN LAMB
    BERNSTEIN, D
    SHADDY, R
    TYNDALL, M
    RUDOLPH, AM
    PEDIATRIC RESEARCH, 1987, 21 (04) : A197 - A197