Changes of intraaortic balloon volume during pumping in a mock circulation system

被引:6
|
作者
Sakamoto, T
Akamatsu, H
Swartz, MT
Shoji, Y
Kazama, S
Fujiyoshi, K
Hashiguchi, Y
Suzuki, A
Miyashita, M
Arai, H
Suzuki, A
机构
[1] ST LOUIS UNIV,ST LOUIS,MO 63103
[2] KOHDEN TOKYO CORP,TOKYO,JAPAN
[3] AISIN HUMAN SYST CO LTD,NAGOYA,AICHI,JAPAN
关键词
intraaortic balloon pumping; mechanical circulatory support; diastolic augmentation; balloon volume;
D O I
10.1111/j.1525-1594.1996.tb04439.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of hemodynamic changes on intraaortic balloon (IAB) volumes were studied experimentally using a helium tachometer in a mock circulatory system. The IAB volume decreased with increases in the heart rate and mean aortic pressure, but the degree of reduction in the IAB volume was different among 4 commercially available IAB drivers. Improvements in IAB consoles are needed to compliment the progress made in percutaneous techniques for IAB insertion resulting in smaller balloons.
引用
收藏
页码:275 / 277
页数:3
相关论文
共 50 条
  • [21] INFLUENCES OF INTRAAORTIC BALLOON PUMPING ON PERIPHERAL HEMODYNAMICS
    SHIMAMOTO, H
    KAWAZOE, K
    KITO, Y
    OHARA, K
    KOSAKAI, Y
    KITO, H
    FUJITA, T
    VASCULAR SURGERY, 1992, 26 (04): : 307 - 312
  • [22] Ventricular energetics during mechanical ventilation and intraaortic balloon pumping - computer simulation
    De Lazzari, C
    Darowski, M
    Ferrari, G
    Clemente, F
    Guaragno, M
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (03) : 103 - 111
  • [23] Effects of timing on ventriculoarterial coupling and mechanical efficiency during intraaortic balloon pumping
    Sakamoto, Tohru
    Suzuki, Akio
    Kazama, Shigeru
    Komatsu, Shigeo
    Sasaki, Shin
    Shoji, Yasushi
    ASAIO Journal, 1995, 41 (03):
  • [24] RECENT EXPERIENCE WITH THE DATASCOPE SYSTEM-90 INTRAAORTIC BALLOON PUMPING CONSOLE
    BERG, GA
    REECE, IJ
    LIFE SUPPORT SYSTEMS, 1987, 5 (03): : 241 - 249
  • [25] A STUDY OF OPTIMAL CONFIGURATION AND CONTROL OF A MULTICHAMBER BALLOON FOR INTRAAORTIC BALLOON PUMPING
    BAI, J
    LIN, H
    YANG, ZB
    ZHOU, XQ
    ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (05) : 524 - 531
  • [26] Aortic Dissection in an Infant Caused by Intraaortic Balloon Pumping
    H. Sakurai
    M. Maeda
    N. Sai
    K. Miyahara
    M. Nakayama
    H. Takemura
    Pediatric Cardiology, 1999, 20 : 373 - 374
  • [27] Current results with Intraaortic balloon pumping in infants and children
    Pinkney, KA
    Minich, LL
    Tani, LY
    Di Russo, GB
    Veasy, LG
    McGough, EC
    Hawkins, JA
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 887 - 891
  • [28] MAJOR DETERMINANTS OF SURVIVAL AND NONSURVIVAL OF INTRAAORTIC BALLOON PUMPING
    PI, KD
    BLOCK, PC
    WARNER, MG
    DIETHRICH, EB
    AMERICAN HEART JOURNAL, 1995, 130 (04) : 849 - 853
  • [29] INTRAAORTIC BALLOON PUMPING IN EXPERIMENTAL ANIMAL - EFFECTS AND PROBLEMS
    FEOLA, M
    ADACHI, M
    AKERS, WW
    ROSS, JN
    WIETING, DW
    KENNEDY, JH
    AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (02): : 129 - &
  • [30] Aortic dissection in an infant caused by intraaortic balloon pumping
    Sakurai, H
    Maeda, M
    Sai, N
    Miyahara, K
    Nakayama, M
    Takemura, H
    PEDIATRIC CARDIOLOGY, 1999, 20 (05) : 373 - 374