Integrated optimal design and sensitivity analysis of a stand alone wind turbine system with storage for rural electrification

被引:16
作者
Belouda, M. [1 ,2 ]
Jaafar, A. [3 ]
Sareni, B. [3 ]
Roboam, X. [3 ]
Belhadj, J. [1 ,2 ]
机构
[1] Univ Tunis, DGE ESSTT, Tunis, Tunisia
[2] Univ Tunis El Manar, ENIT, Tunis 1002, Tunisia
[3] Univ Toulouse, LAPL UMR CNRS INP UPS, Toulouse, France
关键词
Passive wind turbine; Systemic optimization; Integrated Optimal Design; Battery cycles; Total cost of ownership; Sensitivity analysis; OPTIMIZATION; COMBINATION; METHODOLOGY; ISLAND; ARRAY;
D O I
10.1016/j.rser.2013.08.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, the authors investigate a robust Integrated Optimal Design (IOD) devoted to a passive wind turbine system with electrochemical storage bank: this stand alone system is dedicated to rural electrification. The aim of the IOD is to find the optimal combination and sizing among a set of system components that fulfils system requirements with the lowest system Total Cost of Ownership (TCO). The passive wind system associated with the storage bank interacts with wind speed and load cycles. A set of small power passive wind turbines spread on a convenient power range (2-16 kW) are obtained through an IOD process at the device level detailed in previous papers. The system cost model is based on data sheets for the wind turbines and related to battery cycles for the storage bank. From the range of wind turbines, a "system level" optimization problem is stated and solved using an exhaustive search. The optimization results are finally exposed and discussed through a sensitivity analysis in order to extract the most robust solution versus environmental data variations among a set of good solutions. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:616 / 624
页数:9
相关论文
共 36 条
  • [1] Abouzar I, 1991, IEEE T ENERGY CONVER, V6, P445
  • [2] [Anonymous], 2009, World Energy Outlook
  • [3] [Anonymous], 2006, IEEE T ENERGY CONVER
  • [4] Sizing of a stand-alone hybrid wind-photovoltaic system using a three-event probability density approximation
    Bagul, AD
    Salameh, ZM
    Borowy, B
    [J]. SOLAR ENERGY, 1996, 56 (04) : 323 - 335
  • [5] Barkirtzis AG, 1989, IEEE T ENERGY CONVER, V4, P99
  • [6] Belfkira R, 2008, P INT POW EL MOT CON
  • [7] Belouda M., 2011, P 8 INT MULT SYST SI
  • [8] Belouda M, 2012, MELECON HAMM TUN MAR
  • [9] Design of isolated hybrid systems minimizing costs and pollutant emissions
    Bernal-Agustin, Jose L.
    Dufo-Lopez, Rodolfo
    Rivas-Ascaso, David M.
    [J]. RENEWABLE ENERGY, 2006, 31 (14) : 2227 - 2244
  • [10] OPTIMUM PHOTOVOLTAIC ARRAY SIZE FOR A HYBRID WIND PV SYSTEM
    BOROWY, BS
    SALAMEH, ZM
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (03) : 482 - 488