Noninvasive Arterial Blood Pressure Waveforms in Patients with Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Martina, Jerson R. [1 ]
Westerhof, Berend E. [2 ,3 ]
de Jonge, Nicolaas [4 ]
van Goudoever, Jeroen [3 ]
Westers, Paul [5 ]
Chamuleau, Steven [4 ]
van Dijk, Diederik [6 ]
Rodermans, Ben F. M. [7 ]
de Mol, Bas A. J. M. [8 ]
Lahpor, Jaap R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiothorac Surg, NL-3584 CX Utrecht, Netherlands
[2] AMC Ctr Heart Failure Res, Lab Clin Cardiovasc Physiol, Amsterdam, Netherlands
[3] BMEYE BV, Amsterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
[5] Univ Med Ctr Utrecht, Julius Ctr, NL-3584 CX Utrecht, Netherlands
[6] Univ Med Ctr Utrecht, Dept Intens Care, NL-3584 CX Utrecht, Netherlands
[7] Univ Med Ctr Utrecht, Dept Med Technol, NL-3584 CX Utrecht, Netherlands
[8] Univ Amsterdam, Acad Med Ctr, Dept Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
rotary pump; aortic valve; Nexfin; echocardiography; ADVANCED HEART-FAILURE; SUPPORT; MANAGEMENT;
D O I
10.1097/MAT.0000000000000033
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean +/- SD) of systolic, diastolic, mean, and pulse pressures were -7.6 +/- 5.8, -7.0 +/- 5.2, -6.9 +/- 5.1, and -0.6 +/- 4.5 mm Hg, respectively (all < 10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)(max) (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)(max) (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)(max) during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [41] Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices
    Sorensen, Erik N.
    Kon, Zachary N.
    Feller, Erika D.
    Pham, Si M.
    Griffith, Bartley P.
    ANNALS OF THORACIC SURGERY, 2018, 105 (05) : 1377 - 1383
  • [42] Continuous-Flow Left Ventricular Assist Device Implantation in Patients With a Small Left Ventricle
    Kawabori, Masashi
    Kurihara, Chitaru
    Sugiura, Tadahisa
    Cohn, William E.
    Civitello, Andrew B.
    Frazier, O. Howard
    Morgan, Jeffrey A.
    ANNALS OF THORACIC SURGERY, 2018, 105 (03) : 799 - 806
  • [43] Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcome
    Grinstein, Jonathan
    Kruse, Eric
    Sayer, Gabriel.
    Fedson, Savitri
    Kim, Gene H.
    Sarswat, Nitasha
    Adatya, Sirtaz
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Mor-Avi, Victor
    Lang, Roberto M.
    Uriel, Nir
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (08) : 976 - 985
  • [44] Continuous-Flow Left Ventricular Assist Devices and Valvular Heart Disease: A Comprehensive Review
    Noly, Pierre-Emmanuel
    Pagani, Francis D.
    Noiseux, Nicolas
    Stulak, John M.
    Khalpey, Zain
    Carrier, Michel
    Maltais, Simon
    CANADIAN JOURNAL OF CARDIOLOGY, 2020, 36 (02) : 244 - 260
  • [45] Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System
    Bozkurt, Selim
    van de Vosse, Frans N.
    Rutten, Marcel C. M.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (03) : 308 - 315
  • [46] Efficacy and durability of central oversewing for treatment of aortic insufficiency in patients with continuous-flow left ventricular assist devices
    Schechter, Matthew A.
    Joseph, Jeremy T.
    Krishnamoorthy, Arun
    Finet, J. Emanuel
    Ganapathi, Asvin M.
    Lodge, Andrew J.
    Milano, Carmelo A.
    Patel, Chetan B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (09) : 937 - 942
  • [47] Predictors and Clinical Outcomes of Vasoplegia in Patients Bridged to Heart Transplantation With Continuous-Flow Left Ventricular Assist Devices
    Asleh, Rabea
    Alnsasra, Hilmi
    Daly, Richard C.
    Schettle, Sarah D.
    Briasoulis, Alexandros
    Taher, Riad
    Dunlay, Shannon M.
    Stulak, John M.
    Behfar, Atta
    Pereira, Naveen L.
    Frantz, Robert P.
    Edwards, Brooks S.
    Clavell, Alfredo L.
    Kushwaha, Sudhir S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [48] Echocardiographic assessment of flow across continuous-flow ventricular assist devices at low speeds
    George, Robert S.
    Sabharwal, Nikant K.
    Webb, Carole
    Yacoub, Magdi H.
    Bowles, Christopher T.
    Hedger, Michael
    Khaghani, Asghar
    Birks, Emma J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (11) : 1245 - 1252
  • [49] Concomitant aortic valve procedures in patients undergoing implantation of continuous-flow left ventricular assist devices: An INTERMACS database analysis
    Robertson, Jason O.
    Naftel, David C.
    Myers, Susan L.
    Prasad, Sunil
    Mertz, Gail D.
    Itoh, Akinobu
    Pagani, Francis D.
    Kirklin, James K.
    Silvestry, Scott C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06) : 797 - 805
  • [50] Safety of percutaneous endoscopic gastrostomy tube placement in patients with continuous-flow ventricular assist devices
    Keshmiri, Hesam
    Yousuf, Tariq
    Issa, Rasha
    Kurien, Sudha
    Silva, Roeglio
    JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (05) : 1012 - 1015