Noninvasive Arterial Blood Pressure Waveforms in Patients with Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Martina, Jerson R. [1 ]
Westerhof, Berend E. [2 ,3 ]
de Jonge, Nicolaas [4 ]
van Goudoever, Jeroen [3 ]
Westers, Paul [5 ]
Chamuleau, Steven [4 ]
van Dijk, Diederik [6 ]
Rodermans, Ben F. M. [7 ]
de Mol, Bas A. J. M. [8 ]
Lahpor, Jaap R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiothorac Surg, NL-3584 CX Utrecht, Netherlands
[2] AMC Ctr Heart Failure Res, Lab Clin Cardiovasc Physiol, Amsterdam, Netherlands
[3] BMEYE BV, Amsterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
[5] Univ Med Ctr Utrecht, Julius Ctr, NL-3584 CX Utrecht, Netherlands
[6] Univ Med Ctr Utrecht, Dept Intens Care, NL-3584 CX Utrecht, Netherlands
[7] Univ Med Ctr Utrecht, Dept Med Technol, NL-3584 CX Utrecht, Netherlands
[8] Univ Amsterdam, Acad Med Ctr, Dept Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
rotary pump; aortic valve; Nexfin; echocardiography; ADVANCED HEART-FAILURE; SUPPORT; MANAGEMENT;
D O I
10.1097/MAT.0000000000000033
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean +/- SD) of systolic, diastolic, mean, and pulse pressures were -7.6 +/- 5.8, -7.0 +/- 5.2, -6.9 +/- 5.1, and -0.6 +/- 4.5 mm Hg, respectively (all < 10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)(max) (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)(max) (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)(max) during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [31] Device thrombosis in HeartMate II continuous-flow Left ventricular assist devices: A multifactorial phenomenon
    Uriel, Nir
    Han, Jason
    Morrison, Kerry A.
    Nahumi, Nadav
    Yuzefpolskaya, Melana
    Garan, Arthur R.
    Duong, Jimmy
    Colombo, Paolo C.
    Takayama, Hiroo
    Thomas, Sunu
    Naka, Yoshifumi
    Jorde, Ulrich P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) : 51 - 59
  • [32] Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device
    Pinsino, Alberto
    Castagna, Francesco
    Zuver, Amelia M.
    Royzman, Eugene A.
    Nasiri, Mojdeh
    Stohr, Eric J.
    Cagliostro, Barbara
    McDonnell, Barry
    Cockcroft, John R.
    Garan, A. Reshad
    Topkara, Veli K.
    Schulze, P. Christian
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Demmer, Ryan T.
    Willey, Joshua Z.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04) : 396 - 405
  • [33] Noninvasive Blood Pressure Determination in Left Ventricular Assist Device Patients
    Barbara, David W.
    Seelhammer, Troy G.
    Mauermann, William J.
    ANESTHESIOLOGY, 2017, 127 (05) : 902 - 903
  • [34] Risk of pump thrombosis and stroke in patients with continuous-flow left ventricular assist devices and gastrointestinal bleeding
    Szymanski, Thomas W.
    Weeks, Phillip A.
    Patel, Chandni J.
    Jezovnik, Mateja K.
    Gulbis, Brian
    Nathan, Sriram S.
    Jumean, Marwan F.
    Radovancevic, Rajko
    Kar, Biswajit
    Gregoric, Igor D.
    ARTIFICIAL ORGANS, 2020, 44 (11) : 1171 - 1175
  • [35] Effects on pre- and posttransplant pulmonary hemodynamics in patients with continuous-flow left ventricular assist devices
    John, Ranjit
    Liao, Kenneth
    Kamdar, Forum
    Eckman, Peter
    Boyle, Andrew
    Colvin-Adams, Monica
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (02) : 447 - 452
  • [36] Medical management of patients with continuous-flow left ventricular assist devices topical collection on heart failure
    Devore A.D.
    Mentz R.J.
    Patel C.B.
    Current Treatment Options in Cardiovascular Medicine, 2014, 16 (2)
  • [37] Changes in Renal Function After Implantation of Continuous-Flow Left Ventricular Assist Devices
    Hasin, Tal
    Topilsky, Yan
    Schirger, John A.
    Li, Zhuo
    Zhao, Yanjun
    Boilson, Barry A.
    Clavell, Alfredo L.
    Rodeheffer, Richard J.
    Frantz, Robert P.
    Edwards, Brooks S.
    Pereira, Naveen L.
    Joyce, Lyle
    Daly, Richard
    Park, Soon J.
    Kushwaha, Sudhir S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (01) : 26 - 36
  • [38] Living Without a Pulse: The Vascular Implications of Continuous-Flow Left Ventricular Assist Devices
    Purohit, Suneet N.
    Cornwell, William K., III
    Pal, Jay D.
    Lindenfeld, JoAnn
    Ambardekar, Amrut V.
    CIRCULATION-HEART FAILURE, 2018, 11 (06)
  • [39] Discriminatory performance of positive urine hemoglobin for detection of significant hemolysis in patients with continuous-flow left ventricular assist devices
    Gayalas, Michael V.
    Breskin, Alexander
    Yuzefpolskaya, MeLana
    Eisenberger, Andrew
    Castagna, Francesco
    Demmer, Ryan T.
    Flannery, Margaret
    Garan, A. Reshad
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Topkara, Veli K.
    Colombo, Paolo C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01) : 59 - 63
  • [40] Histologic analysis of clots in explanted axial continuous-flow left ventricular assist devices
    Prasad, Sunil M.
    Robertson, Jason O.
    Itoh, Akinobu
    Joseph, Susan M.
    Silvestry, Scott C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04) : 616 - 618